用T-wave离子淌度质谱鉴定猪肌肉中多位点分子离子(六)

2020.6.22

结论

基于对本研究中氟喹诺酮化合物的特征离子化的观察,使用UPLC IMS MSE进行方法开发是合理的。

  ■ 使用离子淌度,可将同一分子,不同质子化物质实现神奇的分离。

  ■ 显示并鉴别了同分子,不同位点质子化合物的碎片谱图。

  ■ 得到每个组分的母离子MS及其MSE碎片谱图

  ■ HDMSE观察结果可以解释在同一实验室内监测特定MRM离子队获得的研究对象报告结果有时 会出现差异的原因。

  ■ 漂移时间值可作为保留时间、母离子精确质量数和碎片精确质量数谱图之外的又一个鉴定条件。

  ■ 离子淌度分离可以有效地将目标峰从基质干扰中分离出来,而不需要对复杂样品进行纯化及色谱分离。


参考文献
1.  Final Decision of the Commissioner, Docket # 2000N-I 57 1 October 24,  2000, Withdrawal of the approval of the new animal drug application for  enrofloxacin in poultry. Department of Health and Human Services, U.S. Food  and Drug Administration.
2.  FDA Center for Veterinary Medicine, June 2, 1997, FDA Order Prohibits  Extralabel Use Of Fluoroquinolones And Glycopeptides.
3.  Official Journal of the European Union, L268:29-43, Regulation (EC) No  1831/2003 of the European Parliament and of the Council of 22 September  2003 on additives for use in animal nutrition.
4.  Official Journal of the European Union, L24:1-8 Annex I, Council Regulation  (EEC) No 2377/90 of 26 June 1990 laying down a Community procedure  for the establishment of maximum residue limits of veterinary medicinal  products in foodstuffs of animal origin.
5.  Verdon E, Couedor P, Roudaut B, Sandérs PJ. Multiresidue Method for  Simultaneous Determination of Ten Quinolone Antibacterial Residues in  Multimatrix/Multispecies Animal Tissues by Liquid Chromatography with  Fluorescence Detection: Single Laboratory Validation Study. AOAC Inter.  2005; 88:1179-1192.
6.  Kaufmann A, Butcher P, Maden K, Widmer M, Giles K, Uria D. Are liquid  chromatography/electrospray tandem quadrupole fragmentation ratios  unequivocal confirmation criteria? Rapid Commun. Mass Spectrom. 2009;   23: 985-998.
7.  Mol HG, Zomer P, de Koning M. Qualitative aspects and validation of a  screening method for pesticides in vegetables and fruits based on liquid  chromatography coupled to full scan high resolution (Orbitrap) mass  spectrometry. Anal Bioanal Chem. 2012; 403:2891-2908.
8.  Croley TR, White KD, Callahan JH, Musser SM. T he chromatographic role   in high resolution mass spectrometry for non-targeted analysis.   J Am Soc Mass Spectrom. 2012; 23:1569.
9.  Commission Decision (2002/657EEC) Official Journal of the European  Communities 2002. 10.  Lalli PM, Iglesias BA, Toma HE, de Sá GF, Daroda RJ, Silva Filho JC,  Szulejko JE, Araki K, Eberlin MN. Protomers: formation, separation and  characterization via travelling wave ion mobility mass spectrometry. J Mass  Spectrom. 2012; 47(6):712-9. 11.  Eberlin MN, Lali PM, Nachtigall FM, Riccio MF, de Sa GF, Daroda RJ, de  Souza V, Campuzano I, Souza GHMF. SYNAPT HDMS: Improving Ion Mobility  Separation by Increasing Drift-Gas Polarizability. Waters Technical Note  720003201en. 2009 October. 12.  Jurneczko E, Kalapothakis J, Campuzano IDG, Morris M, Barran PE. Effects   of drift gas on collision cross sections of a protein standard in linear drift   tube and traveling wave ion mobility mass spectrometry. Anal Chem.   2012; 84(20):8524-31. 13.Asbury GR, Hill HH. Using different drift gases to change separation factors  (alpha) in ion mobility spectrometry. Anal. Chem. 2000; 72(3): 580-4. 14.  Fasciotti M, Sanvido GB, Santos VG, Lalli PM, McCullagh M, de Sá GF,   Daroda RJ, Petera MG, Eberlina MN. J Mass Spectrom. 2012; 47(12):1643-7.