13.260 电击防护 标准查询与下载



共找到 540 条与 电击防护 相关的标准,共 36

This International Standard is applicable to conductive clothing, either assembled from component parts or forming a single complete clothing, worn by (electrically) skilled persons during live working (especially bare-hand working) at a nominal power system voltage up to 800 kV a.c. and ±600 kV d.c. It is applicable to conductive jackets, trousers, coveralls (one-piece clothing), gloves or mitts, hoods, shoes, overshoe socks and socks.

Live working - Conductive clothing for use at nominal voltage up to 800 kV a.c. and +/- 600 kV d.c.

ICS
13.260
CCS
发布
2014-12-25
实施

This International Standard describes a method for calculating the minimum approach distances for live working, at maximum voltages between 72,5 kV and 800 kV. This standard addresses system overvoltages and the working air distances or tool insulation between parts and/or workers at different electric potentials. The required withstand voltage and minimum approach distances calculated by the method described in this standard are evaluated taking into consideration the following: – workers are trained for, and skilled in, working in the live working zone; – the anticipated overvoltages do not exceed the value selected for the determination of the required minimum approach distance; – transient overvoltages are the determining overvoltages; – tool insulation has no continuous film of moisture or measurable contamination present on the surface; – no lightning is seen or heard within 10 km of the work site; – allowance is made for the effect of conducting components of tools; – the effect of altitude, insulators in the gap, etc, on the electric strength is taken into consideration. For conditions other than the above, the evaluation of the minimum approach distances may require specific data, derived by other calculation or obtained from additional laboratory investigations on the actual situation.

Live working - Minimum approach distances for a.c. systems in the voltage range 72,5 kV to 800 kV - A method of calculation

ICS
13.260
CCS
发布
2014-12-25
实施

This International Standard is applicable to electrical insulating gloves and mitts that provide protection of the worker against electric shock. Unless otherwise stated, the use of the term “glove” includes both gloves and mitts. This standard also covers electrical insulating gloves with additional integrated mechanical protection referred to in this document as “composite gloves”. The products designed and manufactured according to this standard contribute to the safety of the users provided they are used by skilled persons, in accordance with safe methods of work and the instructions for use. NOTE Insulating gloves are normally to be used in conjunction with leather protector gloves to provide mechanical protection. Composite insulating gloves are normally used without over-gloves.

Live working - Electrical insulating gloves

ICS
13.260
CCS
发布
2014-12-25
实施

This International Standard is applicable to electrical insulating matting made of elastomer for use as a floor covering for the electrical protection of workers on electrical installations. NOTE 1 For a.c. electrical classification, as well as d.c. use, see 4.2. NOTE 2 This document gives a.c. test provisions. There is limited history for use in d.c. applications. NOTE 3 See Annex A for suggested maximum voltage use

Live working - Electrical insulating matting

ICS
13.260
CCS
发布
2014-12-25
实施

International Standard IEC 1219 applies to equipment-for temporary earthing or earthing and short-circuiting of electrically isolated parts of a.c. installations, the disconnection of which has been verified including the absence of voltage, for the protection of workers while work is in progress using lance(s) (see 3.2.2) as the earthing or earthing and short-circuiting device. The standard specifies the performance and safety requirements and tests for lance devices with matching fixed contacts, guiding arrangements, enclosure, insulating elements and earthing cables, if any. The characteristics of the earthing equipment covered by this standard should be defined on the basis of the intensity and duration of the current, and an voltage when needed for insulation purposes. IEC 855 provides the electrical requirements for separate insulating elements of the equipment. Component types or configurations are not specified but should comply with the electrical and mechanical requirements of this standard. This standard is restricted to equipment using copper bars, aluminium bars or iron bars as short-circuiting medium. NOTE - This standard is not applicable to devices containing short-circuiting cables, which follow the requirements given in IEC 1230.

Live working - Earthing or earthing and short-circuiting equipment using lances as a short-circuiting device - Lance earthing

ICS
13.260
CCS
发布
2014-12-25
实施

This part of IEC 61234 describes the test method for the determination of the hydrolytic stability of moulded thermosets made of room temperature or oven-curing reaction resins when subjected to the simultaneous influence of water and high temperature. With this test method, the irreversible change of mechanical and electrical properties is measured, but no mechanical stress is imposed on the test specimens.

Electrical insulating materials - Methods of test for the hydrolytic stability - Part 2: Moulded thermosets

ICS
13.260
CCS
发布
2014-12-25
实施

This International Standard is applicable to flexible insulating covers (line hoses) for the protection of workers from accidental contact with live or earthed electrical conductors and for the avoidance of short circuits during live working. 1.1 Classes Five classes of conductor covers, differing in electrical characteristics, are provided and designated as class 0, class 1, class 2, class 3, and class 4. 1.2 Categories Six categories of conductor covers differing in composition and properties are provided: category A – acid resistant, category H – oil resistant, category C – formulated for extreme low temperature environments, category W – formulated for extreme high temperature environments, category Z – ozone resistant, and category P – formulated for humid environment. NOTE Types II and III material of ASTM D-1050 would be category Z. 1.3 Styles Various styles of conductor covers, differing in construction characteristics are available and six of these are designated as style A, style B, style C, style D, style E, (see figure 1), and style F.

Live working - Flexible conductor covers (line hoses) of insulating material

ICS
13.260
CCS
发布
2014-12-25
实施

This International Standard is applicable to insulating hollow tubes made of synthetic materials and intended for tools and equipment for work on systems operating at voltages above 1 kV. Separate special technical standards give details of tests for fittings and attachments to these hollow tube terminal parts or complete tools.

Live working - Insulating hollow tubes for electrical purposes

ICS
13.260
CCS
发布
2014-12-25
实施

IEC 61481-1:2014 is applicable to portable phase comparators of capacitive type to be used on electrical systems for voltages exceeding 1 kV a.c. and frequencies of 50 Hz and/or 60 Hz. This standard is applicable to single-pole phase comparators of capacitive type operating with a memory system up to 36 kV a.c., and two-pole phase comparators of capacitive type operating with a wireless connection up to 245 kV a.c. This standard is applicable to phase comparators of capacitive type used in contact with the bare conductive parts to be compared as a complete device including its insulating element or as a separate device, adaptable to an insulating stick which, as a separate tool, is not covered by this standard. A device that is designed to provide other functions than phase comparison is a different device and is not covered by this standard. For example a device designed to be also used as a voltage detector is not covered by this standard. This first edition, together with the first edition of IEC 61481-2, cancels and replaces the first edition of IEC 61481 published in 2001, Amendment 1:2002 and Amendment 2:2004. This edition constitutes a technical revision including the following major changes: - split of the standard in two parts; - extension of the scope to include two-pole phase comparators operating with a wireless connection up to 245 kV a.c.; - review of the requirements for indication; - introduction of a requirement for a new marking "LU" for limited use; - and revision of existing annexes.

Live working - Phase comparators - Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c.

ICS
13.260
CCS
发布
2014-12-05
实施
2015-02-28 (7)

IEC 61481-2:2014 is applicable to portable phase comparators of resistive type to be used on electrical systems for voltages from 1 kV a.c. to 36 kV a.c. and frequencies of 50 Hz and/or 60 Hz. This standard is applicable to phase comparators of resistive type used in contact with the bare conductive parts to be compared as a complete device including its insulating element or as a separate device, adaptable to an insulating stick which, as a separate tool, is not covered by this standard. A device that is designed to provide other functions than phase comparison is a different device and is not covered by this standard. For example a device designed to be also used as a voltage detector is not covered by this standard. This first edition, together with the first edition of IEC 61481-1, cancels and replaces the first edition of IEC 61481 published in 2001, Amendment 1:2002 and Amendment 2:2004. This edition constitutes a technical revision which includes the following major changes: - split of the standard in two parts; - review of the requirements for indication; - elimination of class C (+/- 110°); - introduction of a requirement for a new marking "LU" for limited use; - increase of the specified range of voltage fluctuation in a network for clear indication; - and revision of the existing annexes.

Live working - Phase comparators - Part 2: Resistive type to be used for voltages from 1 kV to 36 kV a.c.

ICS
13.260
CCS
发布
2014-12-05
实施
2015-02-28 (7)

本标准适用于高速公路交通气象监测站的建设及管理。国省干道及其他公路沿线的公路交通气象监测站的建设及管理可参照本标准执行。

Technical specification for the construction of expressway traffic meteorological monitoring station

ICS
13.260
CCS
K 09
发布
2014-11-01
实施
2015-01-01

Live working - Voltage detectors - Capacitive type to be used for a.c. systems of 15 kV and 110 kV with a frequency of 16,7 Hz

ICS
13.260
CCS
F20
发布
2014-09
实施

1.1 This specification covers the in-service care, inspection, testing, and use voltage of insulating gloves and sleeves for protection from electrical shock. 1.2 The values stated in SI units are to be regarded as the standard. See IEEE/ASTM SI-10. 1.3 The following safety hazards caveat pertains only to the test method portion, Sections 6 and 7, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific warning statement, see 7.2.

Standard Specification for In-Service Care of Insulating Gloves and Sleeves

ICS
13.260
CCS
发布
2014-04-01
实施

4.1 Electrical contact injuries to workers may involve a current path through the feet of the worker. The footwear covered by this specification is dielectrically rated to provide additional insulation and isolation to the wearer. This test method will determine that dielectric footwear has dielectric integrity at the time of the test. 1.1 This test method covers testing to determine the “Dielectric Strength” of dielectric overfoot and overshoe footwear. Testing is done over the maximum possible area of the dielectric footwear without permitting flashover between electrodes. 1.2 The use and maintenance of dielectric footwear is beyond the scope of this test method. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in 5.2.

Standard Test Method for Determining Dielectric Strength of Dielectric Footwear

ICS
13.260
CCS
发布
2014-04-01
实施

Live working - Minimum approach distances for a.c systems in the voltage range 72,5 kV to 800 kV - A method of calculation (IEC 61472:2013); German version EN 61472:2013

ICS
13.260
CCS
F20
发布
2014-02
实施
2014-02-01

1.1 This specification covers the in-service care, inspection, testing, and use voltage of insulating gloves and sleeves for protection from electrical shock. 1.2 The values stated in SI units are to be regarded as the standard. See IEEE/ASTM SI-10. 1.3 The following safety hazards caveat pertains only to the test method portion, Sections 6 and 7, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific warning statement, see 7.2.

Standard Specification for In-Service Care of Insulating Gloves and Sleeves

ICS
13.260
CCS
发布
2014
实施

Live working. Voltage detectors. Part 3: Two-pole low-voltage type

ICS
13.260
CCS
发布
2014
实施
2015-10-01

1.1 This specification covers manufacturing and testing of rubber insulating gloves for protection of workers from electrical shock. 1.2 Two types of gloves are provided and are designated as Type I, non-resistant to ozone, and Type II, resistant to ozone. 1.3 Six classes of gloves, differing in electrical characteristics, are provided and are designated as Class 00, Class 0, Class 1, Class 2, Class 3, and Class 4. 1.4 The values stated in SI units are to be regarded as standard. See IEEE/ASTM SI 10. 1.5 The following safety hazards caveat pertains only to the test method portion, Sections 16, 17, 18, and 19, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precaution statements, see 18.2.

Standard Specification for Rubber Insulating Gloves

ICS
13.260
CCS
发布
2014
实施

IEC 62192:2009 covers insulating ropes that are utilized during live working procedures in contact with parts of installations operating at voltages up to and including 800 kV r.m.s. Insulating ropes for live working procedure under rain and/or d.c. conditions are not covered by this standard.

Live working - Insulating ropes

ICS
13.260
CCS
发布
2013-12-31
实施

Live working on low voltage installations - Protective measures implemented - Part 1: General requirements

ICS
13.260
CCS
F20
发布
2013-11-30
实施
2013-11-30



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved