17.180.30 光学测量仪器 标准查询与下载



共找到 403 条与 光学测量仪器 相关的标准,共 27

The standard describes diffraction gratings for spectral decomposition of X-rays. The grating equation, the dispersion and the angular magnification are introduced in detail as physical principles. The different types of diffraction gratings are described. Methods for the determination of structural properties like the groove density are explained.

X-ray optical systems - Diffraction gratings

ICS
17.180.30
CCS
发布
2015-06
实施

1.1 This test method covers the testing of the spectral bandwidth and wavelength accuracy of fluorescence spectrometers that use a monochromator for emission wavelength selection and photomultiplier tube detection. This test method can be applied to instruments that use multi-element detectors, such as diode arrays, but results must be interpreted carefully. This test method uses atomic lines between 250 nm and 1000 nm. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Wavelength Accuracy and Spectral Bandwidth of Fluorescence Spectrometers

ICS
17.180.30
CCS
发布
2015-05-01
实施

State system for ensuring the traceability of measurements. Scanning spectrofluorimeters. Verification procedure

ICS
17.180.30
CCS
N53
发布
2015
实施
2016-06-01

State system for ensuring the traceability of measurements. Optoelectronic instruments as a part of space-based informational and measuring systems for Earth Observation. Organizational and methodical provisions for ensuring the uniformity of radiometric

ICS
17.180.30
CCS
发布
2015
实施
2016-06-01

Optics and optical instruments.Field procedures for testing geodetic and surveying instruments.Part 1: Theory

ICS
17.180.30
CCS
N30
发布
2014-09-22
实施

Optics and optical instruments - Field procedures for testing geodetic and surveying instruments - Part 1: Theory

ICS
17.180.30
CCS
N30
发布
2014-08-01
实施

Optics and optical instruments - Ancillary devices for geodetic instruments - Part 1: Invar levelling staffs

ICS
17.180.30
CCS
N30;A76
发布
2014-08-01
实施

本标准规定了机动车尾气遥测设备的分类、结构、要求、试验方法、检验规则、标志、使用说明书、包装、运输和贮存。本标准适用于应用光谱吸收原理,远距离感应检测行驶中的机动车尾气排放浓度的设备(以下简称遥测仪)。

General technical requirements of remote sensing equipment for motor vehicle exhaust

ICS
17.180.30
CCS
N17
发布
2014-05-06
实施
2014-10-01

Polarimetric saccharimeters are instruments which measure the relationship between the optical rotation caused by an aqueous solution of a sample and that caused by a pure sucrose solution of prescribed concentration, using the same polarized light. This Recommendation applies to polarimetric saccharimeters that are graduated in sugar degrees (!Z) in accordance with the ICUMSA International Sugar Scale (see Annex A) and that belong to the visual or photo-electric type, including: a) saccharimeters with a rotating polarizer or analyser of which the angle of rotation can be measured and which are illuminated by a monochromatic light source of known wavelength which must be between 540 nm and 633 nm; b) saccharimeters with quartz wedge compensation and illuminated either by a monochromatic light source of known wavelength which must be between 540 nm and 633 nm, or by the light of an incandescent lamp filtered in such a way that the distribution of the spectral energy from the lamp, arising from the degree of spectral filtration by the filter and from the spectral sensitivity of the detector (eye or photo-multiplier), permits the use of radiation of effective wavelength 587 nm; c) saccharimeters which operate according to a principle of measurement other than those given in (a) and (b).

Polarimetric saccharimeters graduated in accordance with the ICUMSA International Sugar Scale

ICS
17.180.30
CCS
发布
2014-04-02
实施

This part of ISO 16331 specifies procedures for checking compliance with performance specifications of handheld laser distance meters.

Optics and optical instruments -- Laboratory procedures for testing surveying and construction instruments -- Part 1: Performance of handheld laser distance meters

ICS
17.180.30
CCS
发布
2013-12-31
实施

Basic Requirements for Reflective Fluorescence Confocal Microscopy

ICS
17.180.30
CCS
N32
发布
2013-10-11
实施
2013-11-11

Technical Requirements for Phase Shift Differential Confocal Microscopy

ICS
17.180.30
CCS
N32
发布
2013-10-11
实施
2013-11-11

Basic Requirements for Continuous Spectrum Confocal Microscopy

ICS
17.180.30
CCS
N32
发布
2013-10-11
实施
2013-11-11

Optics and optical instruments.Ancillary devices for geodetic instruments.Part 2: Tripods; Amendment 1

ICS
17.180.30
CCS
N35
发布
2013-09
实施

本标准规定了由集成光学系统、嵌入式软件、显示屏、电源、机壳等组成的便携式车身反光标识检 测仪(以下简称检测仪)的术语和定义、分类和型号、要求、试验方法、检验规则以及标志、包装、运 输、贮存等。 本标准适用于检测仪的设计、制造和检测。

Portable Body Reflective Mark Detector

ICS
17.180.30
CCS
A 60
发布
2013-02-04
实施
2013-03-04

1.1 This practice covers the necessary information to qualify dispersive infrared instruments for specific analytical applications, and especially for methods developed by ASTM International. 1.2 This practice is not to be used as a rigorous test of performance of instrumentation. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Describing and Measuring Performance of Dispersive Infrared Spectrometers

ICS
17.180.30
CCS
发布
2013-01-01
实施

1.1 This practice is intended to serve as a guide for the testing of the performance of a photometric detector (PD) used as the detection component of a liquid-chromatographic (LC) system operating at one or more fixed wavelengths in the range 210 to 800 nm. Measurements are made at 254 nm, if possible, and are optional at other wavelengths. 1.2 This practice is intended to describe the performance of the detector both independently of the chromatographic system (static conditions) and with flowing solvent (dynamic conditions). 1.3 For general liquid chromatographic procedures, consult Refs (1-9).2 1.4 For general information concerning the principles, construction, operation, and evaluation of liquidchromatography detectors, see Refs (10 and 11) in addition to the sections devoted to detectors in Refs (1-7). 1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Testing Fixed-Wavelength Photometric Detectors Used in Liquid Chromatography

ICS
17.180.30
CCS
发布
2013-01-01
实施

Basic principles and applications of monochrator crystals for spectral filtering and focussing of X-rays are described in this guideline. A survey over different types of monochromator crystals is given. Composition, mode of opteration as well as the range of applications will be explained. Different geometries of focusing monochromator crystals are specified.

X-ray optical systems - Monochromator crystals

ICS
17.180.30
CCS
发布
2013-01
实施

State system for ensuring the uniformity of measurements. Tristimulus colorimeters. Method for the determination of channels parameters

ICS
17.180.30
CCS
N52
发布
2013
实施
2015-07-01

本标准规定了由集成光学系统、嵌入式软件、显示屏、电源、机壳等组成的便携式车身反光标识检测仪(以下简称检测仪)的术语和定义、分类和型号、要求、试验方法、检验规则以及标志、包装、运输、贮存等。 本标准适用于检测仪的设计、制造和检测。

Portable Body Reflective Mark Detector

ICS
17.180.30
CCS
A 60
发布
2012-12-24
实施
2013-01-24



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号