Forced draught burners -- Part 2: Oil burners
5.1 Residual fuel oils can contain H2S in the liquid phase, and this can result in hazardous vapor phase levels of H2S in storage tank headspaces. The vapor phase levels can vary significantly according to the headspace volume, fuel temperature, and agitation. Measurement of H2S levels in the liquid phase provides a useful indication of the residual fuel oil’s propensity to form high vapor phase levels, and lower levels in the residual fuel oil will directly reduce risk of H2S exposure. It is critical, however, that anyone involved in handling fuel oil, such as vessel owners and operators, continue to maintain appropriate safety practices designed to protect the crew, tank farm operators and others who can be exposed to H2S. 5.1.1 The measurement of H2S in the liquid phase is appropriate for product quality control, while the measurement of H2S in the vapor phase is appropriate for health and safety purposes. 5.2 This test method was developed so refiners, fuel terminal operators and independent testing laboratory personnel can analytically measure the amount of H2S in the liquid phase of residual fuel oils. Note 1: Test Method D6021 is one of three test methods for quantitatively measuring H2S in residual fuels: 1) Test Method D5705 is a simple field test method for determining H2S levels in the vapor phase. 2) Test Method D7621 is a rapid test method to determine H2S levels in the liquid phase. 5.3 H2S concentrations in the liquid and vapor phase attempt to reach equilibrium in a static system. However, this equilibrium and the related liquid and vapor concentrations can vary greatly depending on temperature and the chemical composition of the liquid phase. A concentration of 1 mg/kg (μg/g) (ppmw) of H2S in the liquid phase of a residual fuel can typically generate an actual gas concentration of >508201;μL/L(ppmv) to 100 μL/L(ppmv) of H2S in the vapor phase, but the equilibrium of the vapor phase is disrupted the moment a vent or access point is opened to collect a sample. Note 2: Because of the reactivity, absorptivity, and volatility of H2S any measurement method only provides an H2S concentration at a given moment in time. 1.1 This test method cover......
Standard Test Method for Measurement of Total Hydrogen Sulfide in Residual Fuels by Multiple Headspace Extraction and Sulfur Specific Detection
Automatic forced draught burners for liquid fuels
This European Standard specifies the terminology, the general requirements for the construction and operation of automatic forced draught oil burners and also the provision of control and safety devices, and the test procedure for these burners.This European Standard applies to automatic forced draught oil burners supplied with:- a fuel having a viscosity at the burner inlet of 1,6 mmÂ2S/s (cSt) up to 6 mmÂ2S/s (cSt) at 20 °C; and - higher boiling petroleum based first raffinates (viscosity greater than 6 mm2/s), that require preheating for proper atomisation.This European Standard is applicable to:- single burners fitted to a single combustion chamber;- si
Automatic forced draught burners for liquid fuels
Automatic forced draught burners for liquid fuels.
This European Standard specifies the terminolog,the general requirements for the construction and operation of automatic forced draught oil burners and also the provision of control and safety devices, and the test procedure for these burners.
Automatic forced draught burners for liquid fuels; German version EN 267:2009+A1:2011
Specification for Jet B Wide-Cut Aviation Turbine Fuel
This re-circulation proposal provides revisions the UL 296 proposal dated 2-4-11.
Standard for Safety for Oil Burners
UL proposes the following change to UL 296: Addition and revision of requirements to relocate component Standard references from Appendix A into the body of the Standard as component requirements.
Standard for Safety for Oil Burners
이 표준은 등유, 경유 또는 중유를 연료로 하는 기름 연소 기기(이하 기기라 한다.)의 연
General rules for structure of oil burning appliances
이 표준은 기름 탱크로부터의 기름의 낙차가 2.5 m 이하에서 사용되는 기름 연소 기기용
Oil controler for oil burning appliances
이 표준은 등유, 경유 또는 중유를 연료로 하고, 연료 소비량1) 5 800 g/h 이하이
Oil burning water heaters for domestic use
이 표준은 등유, 경유 또는 중유를 연료로 하여 주방, 난방, 온수 등에 사용하는 기름 연
General rules for test methods of oil burning appliances
이 표준은 주로 등유를 연료로 하는 기름 연소 기기의 연료 공급에 사용되는 탱크 안의 용적
Oil tanks for oil burning appliances
Filler pumps for oil burning appliances
이 표준은 폴리에틸렌 기름통 및 드럼통 속의 등유를 기름 연소 기기 등으로 옮기기 위해 사
Filler pumps for oil burning appliances
Oil supply copper pipe for oil burning appliances