共找到 703 条与 黑色金属综合 相关的标准,共 47 页
This part of ISO 16918 specifies a method for analysing steel and iron for the trace element determinations of Sn, Sb, Ce, Pb and Bi using inductively coupled plasma mass spectrometry (ICP-MS). The method is applicable for trace elements in the mass fraction ranges (µg/g) as follows: Sn: 5 µg/g to 200 µg/g; Sb: 1 µg/g to 200 µg/g; Ce: 10 µg/g to 1 000 µg/g; Pb: 0,5 µg/g to 100 µg/g; Bi: from 0,3 µg/g to 30 µg/g. Interferences in the determination of trace elements using ICP-MS are listed in Annex B.
Steel and iron -- Determination of nine elements by the inductively coupled plasma mass spectrometric method -- Part 1: Determination of tin, antimony, cerium, lead and bismuth
Application of ISO 5725 for the determination of repeatability and reproducibility of precision tests performed in standardization work for chemical analysis of steel
Steels and irons. Determination of vanadium content. N-BPHA spectrophotometric method
Steels and irons - Determination of vanadium content - N-BPHA spectrophotometric method
What is ISO 4946- Determination of copper- 2,2'-Biquinoline spectrophotometric method about? ISO 4946 is a safety standard on steel and cast iron . ISO 4946 specifies a spectrophotometric method for the determination of copper in steel and cast iron by 2,2’-biquinoline. Note: The method is applicable to the determination of copper mass fraction in the range of 0,02 % and 5 %. Who is ISO 4946- Determination of copper- 2,2'-Biquinoline spectrophotometric method for? ISO 4946 on the determination of copper is relevant to: Manufacturers of steel and cast iron Chemical engineers
Steel and cast iron. Determination of copper. 2,2'-Biquinoline spectrophotometric method
Steels. Determination of total silicon contents. Reduced molybdosilicate spectrophotometric method. Silicon contents between 0,01 % and 0,05 %
Steel and iron. Determination of nickel content. Gravimetric or titrimetric method
Steel. Determination of nickel. Dimethylglyoxime spectrophotometric method
This International Standard specifies a spectrophotometric method for the determination of copper in steel and cas t iron by 2 ,2 ’-biquinoline. The method is applicable to the determination ofcopper mass fraction in the range of0,02 % and 5 %.
Steel and cast iron — Determination of copper — 2,2'-Biquinoline spectrophotometric method
Scope is not provided for this standard
Calculation method of carbon dioxide emission intensity from iron and steel production -- Part 2: Steel plant with electric arc furnace (EAF)
Scope is not provided for this standard
Steel and iron -- Determination of calcium and magnesium -- Inductively coupled plasma atomic emission spectrometric method
Scope is not provided for this standard
Calculation method of carbon dioxide emission intensity from iron and steel production -- Part 1: Steel plant with blast furnace
Iron and steel -- Determination of sulfur content -- Part 4: Infrared absorption method after combustion in an induction furnace (Amendment 1)
This International Standard specifies a potentiometric titration method for the determination of vanadium in steel and cast iron. The method is applicable to vanadium contents between 0,04 and 2 % (m/m).
Steel and cast iron -- Determination of vanadium content -- Potentiometric titration method
This International Standard specifies a spectrophotometric method using reduced molybdosilicate for the determination of total silicon in steel and iron. The method is applicable to silicon contents between 0,01 and 0,05 % (m/m) in steel and iron.
Steel and iron -- Determination of total silicon content -- Reduced molybdosilicate spectrophotometric method -- Part 2: Silicon contents between 0,01 and 0,05 %
This International Standard specifies a 2,2 -diquinolyl spec-trophotometric method for the determination of copper in steel and cast iron. The method is applicable to copper contents between 0,02 and 5 % (m/m).
Steel and cast iron -- Determination of copper content -- 2,2'-Diquinolyl spectrophotometric method
This International Standard specifies a titrimetric method for the determination of sulphur in steel and cast iron, after combustion of the test portion in a current of oxygen.
Steel and cast iron -- Determination of sulphur content -- Combustion titrimetric method
This International Standard specifies a flame atomic absorption spectrometric method for the determination of chromium in non-alloy and low-alloy steels and iron. The method is applicable to chromium contents between 0,002 % (m/m) and 2,0 % (m/m).
Steel and iron -- Determination of chromium content -- Flame atomic absorption spectrometric method
This International Standard specifies a gravimetric method for the determination of the total silicon content in steel and iron. The method is applicable to silicon contents between 0,10 % (m/m) and 5,0 % (m/m) (see note 1). NOTE 1 For samples containing molybdenum, niobium, tantalum, titanium, tungsten, zirconium or high levels of chromium, the results are less precise than for unalloyed steels (see annex A).
Steel and iron -- Determination of total silicon content -- Gravimetric method
This International Standard specifies a spectrophotometric method for the determination of manganese in steel and cast iron. The method is applicable to products having manganese contents between 0,001 and 4 % (m/m).
Steel and cast iron -- Determination of manganese content -- Spectrophotometric method
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号