91.060.40 烟囱、竖井、通风道 标准查询与下载



共找到 396 条与 烟囱、竖井、通风道 相关的标准,共 27

1   Scope This part of BS 5440 specifies requirements for the installation of gas appliances to chimneys , chimney installation work likely to be undertaken by gas engineers and operatives working under UK gas industry conditions, and requirements for the maintenance of chimneys . It is applicable to open-flued chimneys for Type B gas appliances and room-sealed chimney configurations for Type C gas appliances, each of rated input not exceeding 70 kW net (see Note 2 and Note 3), burning 1st, 2nd or 3rd family gases. It applies to chimneys of the natural draught or fanned draught type and is applicable to room-sealed chimneys and open-flued chimneys supplied with the appliance as well as to those supplied separately. NOTE 1 Type B and Type C appliances are explained in Annex A, Table A.1. This part of BS 5440 complements the requirements for the design, installation and commissioning of chimneys as required in BS EN 15287‑1 and BS EN 15287‑2, and provides extra requirements that are specific to the UK gas industry. This part of BS 5440 specifies the following: a) requirements for the selection of the correct chimney configuration option for gas appliances in the UK; ...

Chimneys, flue pipes and ventilation for gas appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd family gases) - Design, installation, commissioning and maintenance of chimneys. Specification

ICS
91.060.40
CCS
发布
2023-12-12
实施
2023-12-12

1   Scope This part of BS 5440 specifies the requirements for the installation and maintenance of ventilation provision relating to gas appliances utilizing 1st, 2nd or 3rd family gases, with a rated heat input not exceeding 70 kW based on net CV (calorific value), used for domestic or non-domestic purposes. NOTE 1 The Institution of Gas Engineers and Managers Standard IGEM/UP/10 covers instances where an appliance installation (not exceeding 70 kW net heat input) is associated with other appliances where the total net heat input exceeds 70 kW. This standard does not cover: a) gas installations in touring caravans, leisure accommodation vehicles or residential park homes; b) decorative fuel effect gas appliances covered by BS 5871‑3; c) cooking appliance installations in catering or educational establishments; or d) hydrogen-only appliances. NOTE 2 This part of BS 5440 can also be used for installations of gas appliances w...

Chimneys, flue pipes and ventilation for gas appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd family gases) - Installation and maintenance of ventilation provision for gas appliances. Specification

ICS
91.060.40
CCS
发布
2023-12-12
实施
2023-12-12

Chimneys. Design, installation and commissioning - Chimneys and connecting flue pipes for room sealed combustion appliances

ICS
91.060.40
CCS
发布
2023-11-30
实施
2023-11-30

Chimneys. Design, installation and commissioning - Chimneys and connecting flue pipes for non-room sealed combustion appliances

ICS
91.060.40
CCS
发布
2023-11-30
实施
2023-11-30

BS EN 13084-1. Free-standing chimneys - Part 1. General requirements

ICS
91.060.40
CCS
发布
2023-07-13
实施
2023-07-13

BS 5440-1. Chimneys, flue pipes and ventilation for gas appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd family gases) - Part 1. Design, installation, commissioning and maintenance of chimneys. Specification

ICS
91.060.40
CCS
发布
2023-06-13
实施
2023-06-13

BS 5440-2. Chimneys, flue pipes and ventilation for gas appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd family gases) - Part 2. Installation and maintenance of ventilation provision for gas appliances. Specification

ICS
91.060.40
CCS
发布
2023-06-13
实施
2023-06-13

3.0.1 排烟空腔体及其周边相邻的空腔体均应采用不燃材料制作, 火灾下不应产生有毒物质;排烟空腔体应确保在排烟时,空腔体背 火表面的温度不大于 80℃,并应符合耐火极限的要求。空腔楼盖 内置排烟管道的耐火极限应符合现行国家标准《建筑防烟排烟系统 技术标准》GB 51251 的相关规定。 3.0.2 混凝土装配箱排烟空腔体顶板、底板和侧壁筒应符合现行行 业标准《装配箱混凝土空心楼盖结构技术规程》JGJ/T 207 的有关 规定。 3.0.3 混凝土装配箱排烟空腔体和钢质网排烟空腔体材料应符合现 行行业标准《装配箱混凝土空心楼盖结构技术规程》JGJ/T 207 和 《现浇混凝土空心楼盖技术规程》JGJ/T 268 的有关规定。 3.0.4 排烟空腔体底板的开洞方式应符合《现浇混凝土空心楼盖技 术规程》JGJ/T 268 的有关规定。 3.0.5 排烟阀和排烟防火阀宜安装在排烟空腔体内,相应排烟空腔 体底面应预留检修口。 3.0.6 排烟空腔体及连接件的整体严密性和漏风量应符合现行行业 标准《通风管道技术规程》JGJ/T141 和现行国家标准《建筑防烟排 烟系统技术标准》GB 51251 的有关规定。 3.0.7 吊挂件应设置在肋梁、框架梁和柱实心区域,严禁设置在排 烟空腔体下底板。 3.0.8 暗管外表覆面层应采用防火隔热材料,覆面层应粘贴牢固, 表面无破损。

Technical standards for built-in mechanical smoke exhaust facilities in concrete cavity floor structures

ICS
91.060.40
CCS
E4710
发布
2023-03-16
实施
2023-04-01

本文件规定了中央厨房通排风系统的布局设计、施工及调试、验收。

Application technical specification for central kitchen ventilation and exhaust system

ICS
91.060.40
CCS
E492
发布
2022-11-24
实施
2022-11-25

本文件规定了消防排烟通风天窗的术语和定义,分类、标记、规格和型号,材料、配件、外观及公差,技术要求,检验和试验方法,检验规则,标志、包装、运输、贮存等。

Fire smoke ventilation skylight

ICS
91.060.40
CCS
CCSP32
发布
2022-04-08
实施
2022-09-01

1.1 These requirements apply to Factory-Built Type A Chimneys, which do not require field fabrication. The chimneys are typically intended for use with gas and liquid fuel-fired residential appliances and building heating equipment, where the appliance or equipment flue-gas temperatures do not exceed 540 °C. 1.2 The chimneys are typically intended for use in accordance with regulatory Codes, such as: a) The National Building Code of Canada; b) CSA B139 Series, Installation Code for Oil Burning Equipment; and c) CSA B149 Series, Natural Gas and Propane Installation Code. 1.3 The chimneys are typically intended for installation inside or outside of buildings to provide an essentially vertical conduit or passageway for conveying flue gases to the outer air from the abovedescribed class of appliances.

STANDARD FOR FACTORY-BUILT TYPE A CHIMNEYS

ICS
91.060.40
CCS
发布
2022-04-07
实施

1.1 These requirements apply to factory-built chimney assemblies which do not require field fabrication. 1.2 The factory-built chimney assemblies are for use with gas, liquid and solid fuel-fired residential appliances and building heating equipment, where the flue-gas temperatures normally do not exceed 650 ºC. 1.3 The factory-built chimney assemblies are intended for installation and use in accordance with the applicable Codes and Regulations as determined by the Authority Having Jurisdiction (AHJ), such as: a) The National Building Code of Canada; b) CSA B139 Series, Installation Code for Oil Burning Equipment; c) CSA B149 Series, Natural Gas and Propane Installation Code; and d) CSA B365, Installation Code for Solid-Fuel Burning Appliances and Equipment 1.4 The factory-built chimney assemblies are intended for installation inside or outside of buildings to provide an essentially vertical conduit or passageway for conveying flue gases to the outer air from the above-described class of appliances.

STANDARD FOR 650 °C FACTORY- BUILT CHIMNEYS

ICS
91.060.40
CCS
发布
2022-04-07
实施

1.1 These requirements cover the design and construction of Type L vents intended for the venting of flue gases having temperatures not exceeding 300 °C, from fuel-burning appliances certified for use with Type L vents. The vents may also be used where Type B gas vents are used. They are intended for installation in buildings to provide a passageway for conveying flue gases to the outer air from the abovedescribed class of appliances. 1.2 These requirements also cover the design and construction of Type PL vents for use in residential dwellings for the venting to the outdoors of the products of combustion from certified automatic particulatefuelled space heaters. 1.3 Vents covered by this Standard are intended for installation in accordance with applicable Codes, such as: a) The National Building Code of Canada; b) CSA B365 – Installation Code for Solid-Fuel Burning Appliances and Equipment; c) CSA B139 Series – Installation Code for Oil-Burning Equipment; and d) CSA B149 Series – Natural Gas and Propane Installation Code.

STANDARD FOR LOW TEMPERATURE VENTS TYPE L AND PL

ICS
91.060.40
CCS
发布
2022-04-07
实施

1.1 These requirements apply to factory-built chimney connectors and wall pass-through assemblies that do not require field fabrication. 1.2 The factory-built chimney connectors and wall pass-through assemblies are for use with gas, liquid and solid-fuel-fired residential appliances and building heating equipment where the flue-gas temperatures do not normally exceed 650 °C. 1.3 Factory-built chimney connectors are intended for use inside buildings to form a connection from an appliance to a factory-built chimney suitable for use with solid fuel, or to a masonry chimney. 1.4 The factory-built chimney connectors and wall pass-through assemblies covered by this Standard are intended for installation and use in accordance with the applicable Codes and Regulations as determined by the Authority Having Jurisdiction (AHJ), such as: a) The National Building Code of Canada; b) CSA B139 Series, Installation code for oil-burning equipment; c) CSA B149 Series, Natural gas and propane installation code; and d) CSA B365 Series, Installation code for solid-fuel-burning appliances and equipment.

STANDARD FOR FACTORY-BUILT CHIMNEY CONNECTORS AND WALL PASS-THROUGH ASSEMBLIES

ICS
91.060.40
CCS
发布
2022-04-07
实施

1.1 The requirements of this Standard cover the design and construction of Type B (round or oval) and Type BW Gas Vents. 1.2 Type B Gas Vents are intended for the venting of flue gases having temperatures not exceeding 245 °C, from gas fired appliances certified with draft hoods or diverters. Type B Gas Vents are also intended for use with gas fired appliances, without draft hoods or diverters, which meet all of the following requirements: a) The appliance is certified for use with a Type B Gas Vent; b) Flue gas temperatures normally exceed 135 °C but do not exceed 245 °C; c) The vent normally operates below atmospheric pressure; and d) Condensation of flue gas products is not normally expected within the vent. 1.3 Type BW Gas Vents are intended for the venting of flue gases from recessed gas fired wall furnaces. The maximum input to a Type BW Gas Vent is determined by the maximum input of the vented wall furnace to which the Type BW Vent is intended to be connected. 1.4 Vents covered by this Standard are intended for installation in accordance with applicable Codes, such as: a) The National Building Code of Canada; and b) The Natural Gas and Propane Installation Code, CSA B149 Series. 1.5 The vents are intended primarily for installation inside buildings to provide an essentially vertical conduit or passageway for conveying flue gases to the outer air from the above described class of appliances. They may be used on the exterior of buildings when enclosed and specifically tested for such an application.

STANDARD FOR GAS VENTS

ICS
91.060.40
CCS
发布
2022-04-07
实施

Chimneys - Accessories - Part 6: Access components - Requirements and test methods

ICS
91.060.40
CCS
发布
2021-10-28
实施
2021-10-28

Chimneys - Accessories - Part 1: Chimney silencers - Requirements and test methods

ICS
91.060.40
CCS
发布
2021-10-28
实施
2021-10-28

Chimneys - Design, installation and commissioning - Part 1: Chimneys and connecting flue pipes for non-room sealed combustion appliances

ICS
91.060.40
CCS
发布
2021-10-15
实施
2021-10-15

Chimneys - Design, installation and commissioning - Part 2: Chimneys and connecting flue pipes for room sealed combustion appliances

ICS
91.060.40
CCS
发布
2021-10-15
实施
2021-10-15

Chimneys -- Components -- Concrete outer wall elements

ICS
91.060.40
CCS
发布
2021-10-06
实施
2021-10-06



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved