1.1 This specification covers 7-wire, 19-wire, 37-wire, and 61-wire zinc-coated (galvanized), zinc-5 % aluminum-mischmetal alloy-coated stranded steel core intended for use in overhead electrical conductors. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

Standard Specification for Metallic Coated Stranded Steel Core for Use in Overhead Electrical Conductors

ICS
29.060.01 (Electrical wires and cables in general)
CCS
K11
发布
2009
实施

1.1 This specification covers bare round copper-clad steel wire for electronic application. 1.2 Four classes of copper-clad steel wire are covered as follows: 1.2.1 Class 30HS—Nominal 308201;% conductivity hard-drawn, 1.2.2 Class 30A—Nominal 308201;% conductivity annealed, 1.2.3 Class 40HS—Nominal 408201;% conductivity hard-drawn, and 1.2.4 Class 40A—Nominal 408201;% conductivity annealed. 1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are in SI units.

Standard Specification for Copper-Clad Steel Wire for Electronic Application

ICS
29.060.10
CCS
K11
发布
2009
实施

1.1 This specification covers shaped wire compact concentric-lay-stranded aluminum conductors, steel supported (ACSS/TW) for use as overhead electrical conductors (see Explanatory Note 1). 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.2.1 Exceptions8212;For conductor sizes designated by AWG or kcmil sizes, the requirements in SI units are numerically converted from the corresponding requirements in inch-pound units. For conductor sizes designation by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values stated or derived in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units. For density, resistivity, and temperature, the values stated in SI units are to be regarded as standard. 1.3 ACSS/TW is designed to increase the aluminum area for a given diameter of conductor by the use of trapezoidal shaped wires (TW). The conductors consist of a central core of round steel wire(s) surrounded by two or more layers of trapezoidal aluminum 1350-0 wires. Different strandings of the same size of conductor are identified by type, which is the approximate ratio of steel area to aluminum area expressed in percent (see Table 1, Table 2, and Table 3). For the purpose of this specification, the sizes listed in Table 1 and Table 2 are tabulated on the basis of the finished conductor having an area or outside diameter equal to that of specified sizes of standard ACSR, ACSS, and ACSR/TW so as to facilitate conductor selection.

Standard Specification for Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Supported (ACSS/TW)

ICS
29.060.10 (Wires)
CCS
K11
发布
2009
实施

1.1 This specification covers concentric-lay-stranded conductors made from round aluminum 1350-H19 (extra hard) wires and round, coated steel core wire(s) for use as overhead electrical conductors (Explanatory Note 1 and Explanatory Note 2). 1.2 ACSR covered by this specification has nine types of coated steel core wire which are designated by abbreviations as follows (Explanatory Note 2): 1.2.1 ACSR/GA or ACSR/GA28212;ACSR using Class A zinc-coated steel wire, 1.2.2 ACSR/GC or ACSR/GC28212;ACSR using Class C zinc-coated steel wire, 1.2.3 ACSR/MA or ACSR/MA28212;ACSR using Class A Zn-5A1-MM coated steel wire, 1.2.4 ACSR/HS or ACSR/GA38212;ACSR using Class A zinc-coated high-strength steel wires, 1.2.5 ACSR/MS or ACSR/MA38212;ACSR using Class A Zn-5A1-MM coated high-strength steel wires, 1.2.6 ACSR/GA48212;ACSR using Class A zinc-coated extra-high-strength steel wires, 1.2.7 ACSR/MA48212;ACSR using Class A Zn-5A1-MM coated extra-high-strength steel wires, 1.2.8 ACSR/GA58212;ACSR using Class A zinc-coated ultra-high-strength steel wires, 1.2.9 ACSR/MA58212;ACSR using Class A Zn-5Al-MM coated ultra-high-strength steel wires. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR)

ICS
29.060.20 (Cables)
CCS
K11
发布
2009
实施

This International Standard specifies the electrical and mechanical characteristics of concentric lay stranded overhead electrical conductors, containing one or more selfsupporting aluminium or aluminium alloy layer(s) as depicted in Figure 1, made of combinations of any of the following metal wires: a) hard-drawn aluminium as per IEC 60889, designated A1; b) aluminium alloy type A or B as per IEC 60104, designated A2 or A3; c) thermal resistant aluminium alloy type as per IEC 62004, designated AT1, AT2, AT3 or AT4; d) regular strength steel as per IEC 60888, designated S1A or S1B; e) high strength steel as per IEC 60888, designated S2A or S2B; f) extra-high strength steel as per IEC 60888, designated S3A; g) aluminium-clad steel as per IEC 61232, designated 20SA, 27SA, 30SA or 40SA. NOTE This standard covers the construction of self-damping conductors, as well as gap-type conductors. Although both types of conductors share a common design feature and the presence of one or more gaps between layers, they are intended for different purposes. Self-damping conductors (SDC) may have more than one gap to provide increased self-damping, whereas gap-type conductors are so designed as to allow the aluminium layers to slide freely over the core during installation, and therefore usually do not require more than one gap.

Concentric lay stranded overhead electrical conductors containing one or more gap(s)

ICS
29.240.20;29.060.10
CCS
K11
发布
2008-09-30
实施
2008-09-30

Covers uninsulated, zinc-coated steel wire in the form of single wires and stranded conductors for use as overhead transmission lines, suspension wires, stay wires, earth conductors and binding and jointing wires.

Conductors for overhead electrical transmission lines Part 5: Zinc-coated steel wires for conductors and stays

ICS
29.240.20
CCS
K11
发布
2008-09-19
实施

Covers uninsulated, non-alloyed copper (in the annealed or in the hard-drawn condition) in the form of single wires and stranded conductors for overhead transmission lines and overhead service connectors.

Conductors for overhead electrical transmission lines Part 1: Copper wires and stranded copper conductors

ICS
29.240.20
CCS
K11
发布
2008-09-19
实施

Applies to copper-covered steel wire in the form of single wires of 30 % and 40 % nominal conductivity, and three grades of breaking strength, for overhead transmission lines for use in telecommunication.

Conductors for overhead electrical transmission lines Part 4: Copper-covered steel wire for telecommunication purposes

ICS
29.240.20
CCS
K11
发布
2008-09-19
实施

Copper-clad aluminum core wire and cable technical regulations

ICS
29.060
CCS
K11
发布
2008-05-13
实施
2008-06-13

This International Standard specifies the electrical and mechanical characteristics of concentric lay stranded overhead electrical conductors, containing one or more selfsupporting aluminium or aluminium alloy layer(s) as depicted in Figure 1, made of combinations of any of the following metal wires: a) hard-drawn aluminium as per IEC 60889, designated A1; b) aluminium alloy type A or B as per IEC 60104, designated A2 or A3; c) thermal resistant aluminium alloy type as per IEC 62004, designated AT1, AT2, AT3 or AT4; d) regular strength steel as per IEC 60888, designated S1A or S1B; e) high strength steel as per IEC 60888, designated S2A or S2B; f) extra-high strength steel as per IEC 60888, designated S3A; g) aluminium-clad steel as per IEC 61232, designated 20SA, 27SA, 30SA or 40SA. NOTE This standard covers the construction of self-damping conductors, as well as gap-type conductors. Although both types of conductors share a common design feature and the presence of one or more gaps between layers, they are intended for different purposes. Self-damping conductors (SDC) may have more than one gap to provide increased self-damping, whereas gap-type conductors are so designed as to allow the aluminium layers to slide freely over the core during installation, and therefore usually do not require more than one gap. The various metal combinations permitted by this standard shall be in accordance with Table 1.

Concentric lay stranded overhead electrical conductors containing one or more gap(s)

ICS
29.060.10;29.240.20
CCS
K11
发布
2008-04
实施
2008-05-01

1.1 This specification covers aluminum 1350-H19 (extra hard), 1350-H16 or -H26 ([n ]hard), 1350-H14 or -H24 (1/2 hard) and 1350-H142 or -H242 (1/2 hard) bare compact-round concentric-lay-stranded conductors made from round or shaped wires for use as uninsulated electrical conductors or in covered or insulated electrical conductors. These conductors shall be composed of a central core surrounded by one or more roller or die compacted layers of helically applied wires (Explanatory Note 1 and Note 2). 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Note 18212;Prior to 1975, aluminum 1350 was designated as EC aluminum. Note 28212;The aluminum and temper designations conform to ANSI Standard H35.1. Aluminum 1350 corresponds to Unified Numbering System A91350 in accordance with Practice E 527.

Standard Specification for Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors

ICS
29.240.20 (Power transmission and distribution lin
CCS
K11
发布
2008
实施

本标准规定了额定电压35kV及以下电力设备母线用热缩管的技术要求、试验方法、检验规则、标志、包装、运输、贮存。 本标准适用于额定电压为35kV及以下电压等级的电力设备母线用热缩管。

Heat shrinkable tube for bus-bars of electrical equipment

ICS
29.060.10
CCS
K11
发布
2007-07-20
实施
2007-12-01

A method of calculating the current-temperature relationship of bare overhead lines, given the weather conditions, is presented. Along with a mathematical method, sources of the values to be used in the calculation are indicated.

Standard for Calculating the Current-Temperature of Bare Overhead Conductors

ICS
17.220.20
CCS
K11
发布
2007-07-11
实施

Although the intended primary application of this Standard is stated in its Scope, it is important to note that it remains the responsibility of the user of the Standard to judge its suitability for his particular purpose.

Cover Plates for Flush-Mounted Wiring Devices

ICS
CCS
K11
发布
2007-05-01
实施

This International Standard is applicable to thermal-resistant aluminium alloy wires before stranding for manufacture of stranded conductors for overhead lines. It specifies the mechanical, electrical and thermal resistant properties of wires in the diameter range commercially available.

Thermal resistant aluminium alloy wire for overhead line conductor

ICS
17.220.20;29.240.20
CCS
K11
发布
2007-02
实施
2007-02-21

1.1 This specification covers high-strength, high-conductivity round copper-alloy wire 0.00099 to 0.0720 in. [0.025 to 1.829 mm] in diameter, used for electronic hookup wire. The tensile strength of the wire is 60 ksi [414 MPa] minimum and the electrical conductivity at 20??C is 858201;% IACS minimum. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for High-Strength, High-Conductivity Copper-Alloy Wire for Electronic Application

ICS
29.060.10 (Wires)
CCS
K11
发布
2007
实施

1.1 This specification covers Aluminum 1350 bar for electric conductors in the tempers shown in .1.2 Aluminum and temper designations are in accordance with ANSI H35.1/H35.1(M). The equivalent Unified Numbering System designation is A91350 in accordance with Practice E 527. Note 1 - For Alloy 6101 bus conductors, refer to Specification B 317/B 317M.Note 2Prior to 1975, Aluminum 1350 was designated as EC aluminum.1.3 A complete metric companion to Specification B 236 has been developed-B 236M; therefore, no metric equivalents appear in this specification.1.4 For acceptance criteria for inclusion of new aluminum and aluminum alloys in this specification, see Annex A2.

Standard Specification for Aluminum Bars for Electrical Purposes (Bus Bars)

ICS
77.150.10 (Aluminium products)
CCS
K11
发布
2007
实施

1.1 This specification covers aluminum alloys in the 8000 series cited in B800 in tempers ???0??? and H1X or H2X bare compact-round, compressed and conventional concentric-lay-stranded conductors made from round or shaped wires used as covered or insulated electrical conductors. These conductors shall be composed of a central core surrounded by one or more compacted, compressed or conventional layers of helically applied wires (Explanatory Note 1 and Note 2). 1.2 The SI values for resistivity are regarded as standard. For all other properties, the inch-pound units are regarded as standard and the SI units may be approximate. 1.3 Sealed conductors that are intended to prevent longitudinal water propagation are also permitted within the guidelines of this specification.

Standard Specification for Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy for Subsequent Covering or Insulation

ICS
29.060.20 (Cables)
CCS
K11
发布
2007
实施

1.1 This specification covers 218201;% conductivity hard-drawn round copper-clad steel wire for coaxial cable center conductors (Note 1). Note 1—Wire ordered to this specification is not intended for redrawing since it is furnished in the hard-drawn temper. If wire is desired for the purpose, the manufacturer should be consulted. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Standard Specification for Copper-Clad Steel Electrical Conductor for CATV Drop Wire

ICS
29.060.10 (Wires)
CCS
K11
发布
2007
实施

1.1 This specification covers silver-coated, soft or annealed, round copper wire, intended for use in electrical equipment, as follows:1.1.1 Class A - Wire whose silver coating is at least 1.25 % of the total weight of the coated wire.1.1.2 Class B - Wire whose silver coating is at least 2.50 % of the total weight of the coated wire.1.1.3 Class C - Wire whose silver coating is at least 4.00 % of the total weight of the coated wire.1.1.4 Class D - Wire whose silver coating is at least 6.10 % of the total weight of the coated wire.1.1.5 Class E - Wire whose silver coating is at least 10.00 % of the total weight of the coated wire.1.2 Silver-coated wire having different minimum percentages of silver by weight may be obtained by mutual agreement between the manufacturer and the purchaser. For information purposes the thickness of coating in microinches provided by the percentages listed above is shown in (Explanatory ).1.3 The SI values of resistance and density are to be regarded as standard. For all other properties values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information purposes only.The following precautionary caveat pertains only to the test method section of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements see Table 1 and Explanatory Note 1.

Standard Specification for Silver-Coated Soft or Annealed Copper Wire

ICS
77.150.30 (Copper products)
CCS
K11
发布
2007
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号