This report is a Technical Report and is of a purely informative nature and is therefore by itself not to be regarded as an International Standard. It is for use by users to assist them with determining and recording verification of conformity of the equ
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-045: Conformity verification report for IEC 61010-2-045:2000; Particular requirements for washer disinfectors used in medical, pharmaceutical, veterinary an
This report is a Technical Report and is of a purely informative nature and is therefore by itself not to be regarded as an International Standard. It is to assist users of the standard with determining and recording verification of conformity of the equ
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-101: Conformity verification report for IEC 61010-2-101:2002; Particular requirements for in vitro diagnostic (IVD) medical equipment
This report is a Technical Report and is of a purely informative nature and is therefore by itself not to be regarded as an International Standard. It is to assist users of the standard with determining and recording verification of conformity of the equ
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-1: Conformity verification report for IEC 61010-1:2001; General requirements
This report is a Technical Report and is of a purely informative nature and is therefore by itself not to be regarded as an International Standard. It is to assist users of the standard with determining and recording verification of conformity of the equ
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-081: Conformity verification report for IEC 61010-2-081:2001; Particular requirements for automatic and semi-automatic laboratory equipment for analysis and
This standard is about Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements; Corrigendum 1
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
This report is for use by test houses and other users to assist them with determining and recording verification of conformity of the equipment under test with the requirements of IEC 61010-031:2002.
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-031: Conformity verification report for IEC 61010-031:2002; Safety requirements for hand-held probe assemblies for electrical test and measurement
This part of IEC 61010 is a technical report, which provides a test protocol to assist with determining and recording verification of conformity of the equipment under test with the reference documents identified on the front cover of the appropriate rep
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3: Protocol for the preparation of conformity verification reports for the IEC 61010 2nd edition series
Electromagnetic locators for buried pipes and cables - Performance and safety.
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101 : particular requirements for in vitro diagnostic (IVD) medical equipment.
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032 : particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement.
Electromagnetic locators for buried pipes and cables - Performance and safety; German version EN 50249:2002
1.1 Scope This International Standard specifies general safety professional,industrial process,and educational use measu rement and test requirements for electrical equipment intended for including equipment and computing devices for: control, laboratory use; accessories intended for use with the above(e g sample handling equipment This Part 1 of the standard applies to the equipment defined in a)to c)below,when used under the environmental conditions of 1 4 a)Electrical measurement and test equipment This is equipment which by electrical means measu res,indicates or records one or more electrical or non-electrical quantities,also non-measu ring equipment such as signal generators measu rement standards,power supplies,transducers,transmitters,etc NOTE—All indicating and recording electrical measuring instruments(except those excluded in 1.1.2) fall within the scope of this standard unless they are panel meters designed only for building-in to other equipment.Built-in panel meters are considered as components and only need to meet the relevant requirements of IEC 1010,or other standards,as part of the equipment into which they are built b)Electrical control equipment This is equipment which controls one or more output quantities to specific values,with each value determined by manual setting,by local or remote programming,or by one or more input variables c)Electrical laboratory equipment This is equipment which measures,indicates,monitors or analyses substances,or is used to prepare materials This equipment may also be used in areas other than laboratories 1.1DV.1 DE Modification Delete”industrial process”and delete the second and third dashes frOm the fi rst paragraph fUL 61010A-1 and UL 61010C-1 apply). Copyright.by the UndenrriLers LaboraLories]nc
UL Standard for Safety Electrical Measuring and Test Equipment; Part 1: General Requirements First Edition
To be read in conjunction with BS EN 61010-1:2001
Safety requirements for electrical equipment for measurement, control and laboratory use - Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement
To be read in conjunction with BS EN 61010-1:2001
Safety requirements for electrical equipment for measurement, control and laboratory use - Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement
Verification Regulation of D.C.Resistance Box
Verification Regulation of DC Low Resistance Meters
Verification Regulation of High Insulation Resistance Meters
Replacement: This part 2 applies to equipment intended for in vitro diagnostic (IVD) medical purposes, including self-test IVD medical purposes. IVD medical equipment, whether used alone or in combination, is intended by the manufacturer to be used in vitro for the examination of specimens, including blood and tissue samples, derived from the human body, solely or principally for the purpose of providing information concerning one or more of the following: a physiological or pathological state; or a congenital abnormality; the determination of safety and compatibility with potential recipients; the monitoring of therapeutic measures. Self-test IVD medical equipment is intended by the manufacturer for use by lay persons in a home environment. NOTE If all or part of the equipment falls within the scope of one or more other part 2 standards of IEC 61010 as well as within the scope of this standard, it will also need to meet the requirements of those other part 2 standards.
Safety requirements for electrical equipment for measurement, control and laboratory use - Particular requirements for in vitro diagnostic (IVD) medical equipment
교 체이 규격은 자동 부하 싣기와 부리기 시스템이 있는 것을 포함하며, 의료 물질
Safety requipements for electrical equipment for measurement, control, and laboratory use-Part 2-42:Particular requirements for autoclaves and sterilizers using toxic gas for the treatment of medical materials and for laboratory processes
교 체 이 규격은 자동 부하 싣기와 부리기 시스템이 있는 것을 포함하여 의료 물질
Safety requipements for electrical equipment for measurement, control, and laboratory use-Part 2-43:Particular requirements for dry heat sterilizers using either hot air or hot inert gas for the treatment of medicals materials, and for laboratory processe