Q24 密封材料 标准查询与下载



共找到 845 条与 密封材料 相关的标准,共 57

This document specifies definitions and characteristics of flexible reinforced bitumen sheets for which the intended use is as water vapour control layers for buildings. It specifies the requirements and test methods and provides for the evaluation of conformity of the products with the requirements of this document.

Flexible sheets for waterproofing - Plastic and rubber vapour control layers - Definitions and characteristics; German version EN 13984:2004/A1:2006

ICS
CCS
Q24
发布
2007-02-01
实施

This document specifies definitions and characteristics of flexible reinforced bitumen sheets for which the intended use is as water vapour control layers for buildings. It specifies the requirements and test methods and provides for the evaluation of conformity of the products with the requirements of this document.

Flexible sheets for waterproofing - Bitumen water vapour control layers - Definitions and characteristics; English version of DIN EN 13970/A1:2007-02

ICS
01.040.91;91.100.50
CCS
Q24
发布
2007-02
实施

This standard specifies a method of determining mass and volume changes in sealants that are self-levelling during application. It does not apply to non-sag sealants, the testing of which is specified in DIN EN ISO 10563.

Testing of sealing materials for buildings - Part 1: Determination of change in mass and volume of self-levelling joint sealants

ICS
91.100.50
CCS
Q24
发布
2007-01
实施

1.1 This specification covers joint and crack sealants of the hot applied type intended for use in sealing joints and cracks in Portland Cement Concrete and Asphaltic Concrete Pavements. 1.2 This specification does not purport to cover the properties required of sealants for use in areas of Portland Cement concrete or asphaltic pavement subject to jet fuel or other fuel spillage such as vehicle and/or aircraft refuel and maintenance areas. 1.3 The values stated in SI units are the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

Standard Specification for Joint and Crack Sealants, Hot Applied, for Concrete and Asphalt Pavements

ICS
93.080.20 (Road construction materials)
CCS
Q24
发布
2007
实施

Liquid-applied glazing materials, bedding sealants, glazing compounds (that is, glazing sealants) are designed to provide a seal between the IG unit and the window or wall framing. Frequently there is physical contact between these materials and an IG unit edge sealant. Depending on the particular IG unit edge sealant, there can be a detrimental physical or chemical interaction between it and the liquid-applied glazing material. Detrimental effects may include: weakening, softening, hardening, or adhesive failure of the IG edge sealant, or visual obstruction inside the IG unit.1.1 This test method covers a laboratory procedure for quantitatively measuring the compatibility of liquid-applied glazing materials with an insulating glass unit edge sealant. Compatibility is determined by measuring the changes in the insulating glass edge sealant adhesive and cohesive properties. Hereinafter insulating glass is referred to as IG. 1.2 This test method does not address the issue of the integrity of the hermetic seal or changes to the vision area in an IG unit. Such factors as possible unit fogging or primary sealant reaction in a dual-seal system due to volatile components permeating the IG sealant are not considered in this test method. 1.3 The committee with jurisdiction over this standard is not aware of any comparable standards published by other organizations. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Compatibility of Insulating Glass Edge Sealants with Liquid-Applied Glazing Materials

ICS
81.040.30 (Glass products)
CCS
Q24
发布
2007
实施

1.1 This specification provides requirements for membrane-forming liquids suitable for use as curing compounds and sealers on freshly placed concrete and as sealers on hardened concrete. These membranes have special properties, such as, alkali resistance, acid resistance, adhesion-promoting qualities, and resistance to degradation by UV light.Note 1For liquid membrane-forming curing compounds specified primarily by their ability to retain water in newly placed concrete (and by drying time, and for white pigmented products, reflectance), see Specification C 309.1.2 The values stated in SI units are to be regarded as the standard. (Inch pound units are shown in parentheses).The following precautionary caveat pertains only to the test methods portion, Section , of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.3 This is a performance specification. The allowable composition of products covered by this specification is limited by various local, regional, and national regulations. Issues related to air quality (solvent emission), worker exposure, and other hazards are not addressed here. It is the responsibility of the producers and users of these materials to comply with pertinent regulations.Warning-Some VOC exempt solvents used to meet the regulations are extremely flammable with low auto ignition temperatures and rapid evaporation rates. Consult the manufacturer''s product information sheet for important application and safety information.

Standard Specification for Liquid Membrane-Forming Compounds Having Special Properties for Curing and Sealing Concrete

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q24
发布
2007
实施

1.1 This guide covers the use of lock-strip gaskets in compliance with Specification C542 in walls of buildings not over 15?? from a vertical plane. The prime performance considerations are weathertightness against air and water infiltration, and structural integrity under wind loads. Included are terminology, design considerations, and fabrication tolerances when using lock-strip gaskets in glazing applications. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Guide for Lock-Strip Gasket Glazing

ICS
91.060.50 (Doors and windows)
CCS
Q24
发布
2007
实施

Liquid-applied glazing materials, bedding sealants, glazing compounds (that is, glazing sealants) are designed to provide a seal between the IG unit and the window or wall framing. Frequently there is physical contact between these materials and an IG unit edge sealant. Depending on the particular IG unit edge sealant, there can be a detrimental physical or chemical interaction between it and the liquid-applied glazing material. Detrimental effects may include: weakening, softening, hardening, or adhesive failure of the IG edge sealant, or visual obstruction inside the IG unit.1.1 This test method covers a laboratory procedure for quantitatively measuring the compatibility of liquid-applied glazing materials with an insulating glass unit edge sealant. Compatibility is determined by measuring the changes in the insulating glass edge sealant adhesive and cohesive properties. Hereinafter insulating glass is referred to as IG. 1.2 This test method does not address the issue of the integrity of the hermetic seal or changes to the vision area in an IG unit. Such factors as possible unit fogging or primary sealant reaction in a dual-seal system due to volatile components permeating the IG sealant are not considered in this test method. 1.3 The committee with jurisdiction over this standard is not aware of any comparable standards published by other organizations. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Compatibility of Insulating Glass Edge Sealants with Liquid-Applied Glazing Materials

ICS
81.040.30
CCS
Q24
发布
2007
实施

1.1 This specification covers liquid membrane-forming compounds suitable for application to concrete surfaces to reduce the loss of water during the early-hardening period. White-pigmented membrane-forming compounds serve the additional purpose of reducing the temperature rise in concrete exposed to radiation from the sun. The membrane-forming compounds covered by this specification are suitable for use as curing media for fresh concrete, and may also be used for further curing of concrete after removal of forms or after initial moist curing. Note 1This specification addresses only those properties listed in Sections through . Membrane-forming compounds with special properties including better water retention, minimum solids content, resistance to ultraviolet radiation, acid and alkali resistance and non-interference with adhesives are described in Specification C 1315.Note 2Solutions of silicate salts are chemically reactive in concrete rather than membrane-forming; therefore, they do not meet the intent of this specification.1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are provided for informational purposes only. 1.3 The following precautionary caveat pertains only to the test methods portion, Section , of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes shall not be considered as requirements of the standard. 1.5 This is a performance specification. The allowable composition of products covered by this specification is limited by various local, regional, and national regulations. Issues related to air quality (solvent emission), worker exposure, and other hazards are not addressed here. It is the responsibility of the producers and users of these materials to comply with pertinent regulations.Warning-Some VOC exempt solvents used to meet the regulations are extremely flammable with low auto ignition temperatures and rapid evaporation rates. Consult the manufacturer''s product information sheet for important application and safety information.

Standard Specification for Liquid Membrane-Forming Compounds for Curing Concrete

ICS
91.100.30 (Concrete and concrete products)
CCS
Q24
发布
2007
实施

1.1 This specification describes the properties of cold, liquid-applied, single or multi-component, chemically curing, elastomeric sealants used as the secondary seal of sealed insulating glass units, hereinafter referred to as the "sealant" (see Fig. 1). These sealants are intended to be a structural component of sealed insulating glass (IG) units used in structural sealant glazing (hereinafter referred to as SSG). Typical designs and considerations can be found in Guide C 1249. Presently only certain silicone sealants are recognized as having the necessary durability for use as secondary sealant in IG units in SSG applications.1.2 This specification does not describe all of the necessary properties of the sealant. Only those properties for which there are ASTM test methods and industry-agreed-upon minimum acceptable test requirements are described by this specification. Additional properties will be added as ASTM test methods for these properties become available.1.3 This specification only addresses the durability of the secondary edge sealants for structurally glazed insulating glass units. Durability of sealed insulating glass units can be found in specifications and guides that reside within ASTM Committee E06.1.4 The committee with jurisdiction for this standard is not aware of any comparable standard published by other organizations.1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information purposes only.

Standard Specification for Secondary Edge Sealants for Structurally Glazed Insulating Glass Units

ICS
81.040.20 (Glass in building); 91.100.50 (Binders.
CCS
Q24
发布
2007
实施

1.1 Structural sealant glazing, hereinafter referred to as SSG, is an application where a sealant not only can function as a barrier against the passage of air and water through a building envelope, but also primarily provides structural support and attachment of glazing or other components to a window, curtain wall, or other framing system.1.2 This guide provides information useful to design professionals, manufacturers, contractors, and others for the design and installation of a SSG system. This information is applicable only to this glazing method when used for a building wall that is not more than 15176; from vertical; however, limited information is included concerning a sloped SSG application.1.3 Only a silicone chemically curing sealant specifically formulated, tested, and marketed for structural sealant glazing is acceptable for a SSG system application.1.4 The committee with jurisdiction for this standard is not aware of any comparable standard published by other organizations.1.5 The calculations and values stated in SI units are to be regarded as the standard. Values in parenthesis and inch-pound units are for information only. SI units in this guide are in conformance with IEEE/ASTM SI 10.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Guide for Structural Sealant Glazing

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q24
发布
2007
实施

1.1 This standard covers terms, related standard definitions, and descriptions of terms used or likely to be used in standard test methods, specifications, guides, and practices (related to building seals and sealants) consistent with the scope and areas of interest of ASTM Committee C24.1.2 Definitions and descriptions of terms are written to ensure that building seals and sealants standards are properly understood and interpreted.

Standard Terminology of Building Seals and Sealants

ICS
01.040.91 (Construction materials and building (Vo
CCS
Q24
发布
2007
实施

1.1 This test method covers a laboratory procedure for quantitatively measuring the compatibility of liquid-applied glazing materials with an insulating glass unit edge sealant. Compatibility is determined by measuring the changes in the insulating glass edge sealant adhesive and cohesive properties. Hereinafter insulating glass is referred to as IG.1.2 This test method does not address the issue of the integrity of the hermetic seal or changes to the vision area in an IG unit. Such factors as possible unit fogging or primary sealant reaction in a dual-seal system due to volatile components permeating the IG sealant are not considered in this test method.1.3 The committee with jurisdiction over this standard is not aware of any comparable standards published by other organizations.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Compatibility of Insulating Glass Edge Sealants with Liquid-Applied Glazing Materials

ICS
81.040.30 (Glass products)
CCS
Q24
发布
2007
实施

Sealing of exterior wall joints in building using joint sealants

ICS
91.100.50
CCS
Q24
发布
2006-12
实施

  本标准规定了建筑接缝用丙烯酸酯密封胶的产品的分类、要求、试验方法、检验规则及标志、包装、运输、贮存的基本要求。   本标准适用于以丙烯酸酯乳液为基料的单组分水乳型建筑密封胶。

Acrylic sealant for building

ICS
91.100.50
CCS
Q24
发布
2006-11-03
实施
2007-04-01

  本标准规定了建筑工程接缝用聚硫密封胶产品的分类、要求、试验方法、检验规则及标志、包装、运输、贮存的基本要求。   本标准适用于以液态聚硫橡胶为基料的室温硫化双组分建筑密封胶。

Polysulfide sealant for building

ICS
91.100.50
CCS
Q24
发布
2006-11-03
实施
2007-04-01

 本标准规定了橡胶石棉密封填料、油浸石棉密封填料、聚四氟乙烯石棉密封填料的术语和定义、分类、技术要求、试验方法、检验规则以及包装、标志、运输、贮存。   本标准适用于压力为8MPa以下、温度为550℃以下的蒸汽机、往复泵的活塞和阀门杆上的橡胶石棉密封填料;压力为4.5MPa以下、温度为350℃以下,介质为蒸汽、空气、工业用水、重质石油产品的回转轴、往复泵的活塞和阀门杆上的油浸石棉密封填料;压力为12MPa以下、温度为-100℃~250℃的管道阀门、活塞杆上的聚四氟乙烯石棉密封填料。

Asbestos sealing packing

ICS
91.100.50
CCS
Q24
发布
2006-11-03
实施
2007-04-01

本标准规定了油浸棉、麻密封填料的术语和定义、分类、技术要求、试验方法、检验规则以及包装、标志、运输、贮存。 本标准适用于介质极限压力为12MPa、温度为120℃以下的管道、阀门、旋转轴、往复泵的活塞杆的油浸棉、麻密封填料。

Cotton and flax oil-soaking sealing packing

ICS
91.100.50
CCS
Q24
发布
2006-11-01
实施
2007-04-01

This European Standard is applicable to bitumen sheets intended for use with a layer of mastic asphalt. This European Standard specifies a test method for the evaluation of the resistance of bitumen sheets to the rising of the bitumen compound at the application of mastic asphalt in a non-floating manner. NOTE This European Standard could also be used for bitumen sheets intended for use with other asphalt types as a protection layer.

Flexible sheets for waterproofing - Waterproofing of concrete bridge decks and other concrete surfaces trafficable by vehicles - Determination of the behaviour of bitumen sheets during application of mastic asphalt; English version of DIN EN 14693:2006-11

ICS
91.100.50
CCS
Q24
发布
2006-11
实施

This prestandard covers the use of flexible sheets for waterproofing of roofs in accordance with European roduct standards

Use of building products in construction works - Part 201: Adaption standard for flexible sheets for waterproofing according to European standards for the use as waterproofing of roofs

ICS
91.100.50
CCS
Q24
发布
2006-11
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved