13.320;17.060;29.260.20 标准查询与下载



共找到 10 条与 相关的标准,共 1

Electrical apparatus for the detection and measurement of flammable gases - Part 3 : performance requirements for group I apparatus indicating a volume fraction up to 100 % methane in air.

ICS
13.320;17.060;29.260.20
CCS
N50
发布
2005-01-01
实施
2005-01-20

Electrical apparatus for the detection and measurement of flammable gases - Part 4 : performance requirements for group II apparatus indicating a volume fraction up to 100 % lower explosive limit.

ICS
13.320;17.060;29.260.20
CCS
N50
发布
2005-01-01
实施
2005-01-20

Electrical apparatus for the detection and measurement of flammable gases - Part 5 : performance requirements for group II apparatus indicating a volume fraction up to 100 % gas.

ICS
13.320;17.060;29.260.20
CCS
N50
发布
2005-01-01
实施
2005-01-20

Electrical apparatus for the detection and measurement of flammable gases - Part 1 : general requirements and test methods.

ICS
13.320;17.060;29.260.20
CCS
N50
发布
2005-01-01
实施
2005-01-20

Electrical apparatus for the detection and measurement of flammable gases - Part 2 : performance requirements for group I apparatus indicating a volume fraction up to 5 % methane in air.

ICS
13.320;17.060;29.260.20
CCS
N50
发布
2005-01-01
实施
2005-01-20

1 This part of IEC 61779 specifies general requirements for construction and testing and describes the test methods that apply to portable, transportable and fixed apparatus for the detection and measurement of flammable gas or vapour concentrations with air. The apparatus, or parts thereof, are intended for use in potentially explosive atmospheres (see 2.1.8) and in mines susceptible to firedamp. This standard is supplemented by the following standards, concerning the specific requirements for the performance of the various types of apparatus: IEC 61779-2: Performance requirements for group I apparatus indicating up to a volume fraction of 5 % methane in air IEC 61779-3: Performance requirements for group I apparatus indicating up to a volume fraction of 100 % methane in air IEC 61779-4: Performance requirements for group II apparatus indicating up to a volume fraction of 100 % lower explosive limit IEC 61779-5: Performance requirements for group II apparatus indicating up to a volume fraction of 100 % gas Note deleted NOTE 1 - Group I and group II apparatus indicating up to a volume fraction of 100 % methane and group II apparatus indicating up to a volume fraction of 100 % gas are suitable for use only with the specific gases for which they have been calibrated. NOTE 2 - For the purpose of this standard, the terms "lower flammable limit (LFL)" and "lower explosive limit (LEL)" are deemed to be synonymous, and likewise the terms "upper flammable limit (UFL)" and "upper explosive limit (UEL)" are deemed to be synonymous. For ease of reference, the two abbreviations LFL and UFL may be used hereinafter to denote these two sets of terms. It should be recognized that particular authorities having jurisdiction may have overriding requirements that dictate the use of one of these sets of terms and not the other. 2 This standard is applicable when an apparatus manufacturer makes any claims regarding any special features of construction or superior performance that exceed these minimum requirements. All such claims shall be verified and the test procedures shall be extended or supplemented, where necessary, to verify the claimed performance. The additional tests shall be agreed between the manufacturer and test laboratory. 3 This standard is applicable to flammable gas detection apparatus intended to provide an indication, alarm or other output function, the purpose of which is to give a warning of a potential explosion hazard and, in some cases, to initiate automatic or manual protective action(s). 4 This standard is applicable to apparatus, including the integral sampling systems of aspirated apparatus, intended to be used for commercial and industrial safety applications. 5 This standard does not apply to external sampling systems, or to apparatus of laboratory or scientific type, or to apparatus used only for process control purposes.

Electrical apparatus for the detection and measurement of flammable gases - General requirements and test methods

ICS
13.320;17.060;29.260.20
CCS
N55
发布
2000-09-15
实施
2000-09-15

1 This part of IEC 61779 specifies requirements for group I (as defined in part 1) portable, transportable and fixed apparatus for the detection and measurement of methane concentrations in mine air. The apparatus, or parts thereof, are intended for use in mines susceptible to firedamp. The requirements and test methods applicable to the apparatus covered by this standard are specified in part 1. 2 This standard is restricted to apparatus intended for the detection and measurement of volume ratios of methane in air from a volume fraction of 0 % up to, but not exceeding, a volume fraction of 5 %.

Electrical apparatus for the detection and measurement of flammable gases - Performance requirements for group I apparatus indicating a volume fraction up to 5% methane in the air

ICS
13.320;17.060;29.260.20
CCS
N55
发布
2000-09-15
实施
2000-09-15

1 This part of IEC 61779 specifies requirements for group I (as defined in part 1) portable, transportable and fixed apparatus for the detection and measurement of methane concentrations in mine air. The apparatus, or parts thereof, are intended for use in mines susceptible to firedamp. The requirements and test methods applicable to the apparatus covered by this standard are specified in part 1. 2 This standard is restricted to apparatus intended for the detection and measurement of volume ratios of methane in air from a volume fraction of 0 % up to, but not exceeding, a volume fraction of 5 %.

Electrical apparatus for the detection and measurement of flammable gases - Performance requirements for group I apparatus indicating a volume fraction up to 100% methane in air

ICS
13.320;17.060;29.260.20
CCS
N55
发布
2000-09-15
实施
2000-09-15

1 This part of IEC 61779 specifies requirements for group II (as defined in part 1) portable, transportable and fixed apparatus for the detection and measurement of combustible gas or vapour concentrations with air. The apparatus, or parts thereof, may be installed or used in potentially explosive atmospheres, other than mines susceptible to firedamp (i.e. group I). The requirements and test methods applicable to the apparatus covered by this standard are specified in part 1. 2 This standard is restricted to apparatus intended for the detection and measurement of combustible gas or vapour concentrations with air up to 100 % lower explosive limit (LEL).

Electrical apparatus for the detection and measurement of flammable gases - Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit

ICS
13.320;17.060;29.260.20
CCS
N55
发布
2000-09-15
实施
2000-09-15

1 This part of IEC 61779 specifies requirements for group II (as defined in part 1) portable, transportable and fixed apparatus for the detection and measurement of combustible gas or vapour concentrations with air. The apparatus, or parts thereof, may be installed or used in potentially explosive atmospheres, other than mines susceptible to firedamp (i.e. group I). The requirements and test methods applicable to the apparatus covered by this standard are specified in part 1. 2 This standard is restricted to apparatus intended for the detection and measurement of volume ratios of combustible gas or vapour in air in volume fractions from 0 % to 100 % . NOTE 1 - Apparatus covered by this standard will normally be intended to operate in volume ratios greater than 100%LEL. NOTE 2 - Although apparatus of the types covered by this standard may be suitable for detecting a wide range of combustible gases, particular gases (e.g. methane or propane) are specified in part 1 as the components of the test gases for the purpose of practical convenience. The performance requirements specified in this standard should therefore be considered with caution when the apparatus is used to detect other combustible gases, as some parameters - such as time of response - will be modified.

Electrical apparatus for the detection and measurement of flammable gases - Performance requirements for group II apparatus indicating a volume fraction up to 100% gas

ICS
13.320;17.060;29.260.20
CCS
N55
发布
2000-09-15
实施
2000-09-15



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved