共找到 275 条与 电阻器综合 相关的标准,共 19 页
Analog resistance detection technology method
本文件规定了双帽晶圆绕线电阻器的术语和定义、结构与基本参数、基本要求、技术要求、试验方法、检验规则、标志、包装、运输、贮存及质量承诺等要求。 本文件适用于氧化铝陶瓷棒材质双头均装有双帽,电阻丝为缠绕结构的双帽晶圆绕线电阻器(以下简称电阻器)。
Double cap wafer wire wound resistor
Laboratory resistors - Part 1: Laboratory DC resistors
Laboratory resistors - Part 2: Laboratory AC resistors
Method of measurement of non-linearity in resistors
Method of measurement of non-linearity in resistors
Low resistance measurements — Methods and guidance
Low resistance measurements — Methods and guidance
1 Scope Resistance measurements are typically compromised by a variety of phenomena, for example serial resistance in the measurement path, self-heating or non-ohmic properties. Whether the effect of such phenomena on a resistance measurement is acceptable or not depends on the magnitude of each effect in comparison to the resistance and to the required accuracy. Hence, the risk of erroneous resistance measurements increases with decreasing resistance and with a tightening of the permissible tolerance. This document specifies methods of measurement and associated test conditions that eliminate or reduce the influence of adverse phenomena in order to improve the attainable accuracy of low-resistance measurements. The methods described in this document are applicable for the individual measurements of the resistance of individual resistors, and also for resistance measurements as part of a test sequence. They are applied if prescribed by a relevant component specification, or if agreed between a customer and a manufacturer.
Low resistance measurements. Methods and guidance
Wires and rolled wires for electrical heating
Resistance measurements are typically compromised by a variety of phenomena@ for example serial resistance in the measurement path@ self-heating or non-ohmic properties. Whether the effect of such phenomena on a resistance measurement is acceptable or not depends on the magnitude of each effect in comparison to the resistance and to the required accuracy. Hence@ the risk of erroneous resistance measurements increases with decreasing resistance and with a tightening of the permissible tolerance. This document specifies methods of measurement and associated test conditions that eliminate or reduce the influence of adverse phenomena in order to improve the attainable accuracy of low-resistance measurements. The methods described in this document are applicable for the individual measurements of the resistance of individual resistors@ and also for resistance measurements as part of a test sequence. They are applied if prescribed by a relevant component specification@ or if agreed between a customer and a manufacturer.
Low resistance measurements – Methods and guidance
Wires and rolled wires for electrical heating
WIRES AND ROLLED WIRES FOR ELECTRICAL HEATING
Method of measurement of non-linearity in resistors (IEC 60440:2012); German version EN 60440:2012
Method of measurement of non-linearity in resistors (IEC 60440:2012)
Standard for Safety for Conductive-Path and Discharge-Path Resistors for Use in Radio-, Video-, or Television-Type Appliances
Standardizes a method of measurement and associated test conditions for determining the magnitude of non-linear distortion generated in a resistor. Has the status of a technical report.The contents of the corrigendum of September 1974 have been included i
Method of measurement of non-linearity in resistors
Method of measurement of non-linearity in resistors
This drawing describes the requirements for a fixed, film, surface mount, 2.25 watts (20 watts with a heatsink) power device.
RESISTOR, CHIP, FIXED, FILM, SURFACE MOUNT, 2.25 WATTS (UP TO 20 WATTS WITH HEATSINK)
This drawing describes the requirements for a fixed, film, surface mount, 2.25 watts (20 watts with a heatsink) power device.
RESISTOR, FIXED, FILM, RADIAL LEAD, 2.25 WATTS (UP TO 20 WATTS WITH HEATSINK)
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号