31.160;33.040.30;97.120 标准查询与下载



共找到 9 条与 相关的标准,共 1

Signalling on low voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 4-4 : low voltage decoupling filter - Impedance filter.

ICS
31.160;33.040.30;97.120
CCS
M62
发布
2005-03-01
实施
2005-03-20

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 4-5: Low voltage decoupling filter; Segmentation filter; German version EN 50065-4-5:2003

ICS
31.160;33.040.30;97.120
CCS
M30
发布
2003-06
实施
2003-06-01

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 4-4: Low voltage decoupling filter; Impedance filter; German version EN 50065-4-4:2003

ICS
31.160;33.040.30;97.120
CCS
M30
发布
2003-06
实施
2003-06-01

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 4-3: Low voltage decoupling filter; Incoming filter; German version EN 50065-4-3:2003

ICS
31.160;33.040.30;97.120
CCS
M30
发布
2003-06
实施
2003-06-01

This standard applies to incoming filters used to control the coupling of signals between the utility area and the consumer area (see Figure 1). The standard defines · the minimum impedance in the relevant frequency band(s) at both Utility port and Consumer port, · the minimum attenuation of unwanted signals transmitted from the utility side to the consumer side and vice versa, · the transmission characteristics: - operating frequency domain for both utility side and consumer side, - attenuation between the utility side and the consumer side and vice versa, - impedance at the utility side and at the consumer side. This standard applies to incoming filters designed for and used in single or multiphase installations.

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148.5 kHz - Low voltage decoupling filters - Incoming filter

ICS
31.160;33.040.30;97.120
CCS
K30
发布
2003-04-15
实施
2003-04-15

This standard applies to impedance filters in a mains communication system for phase to neutral voltage not exceeding 250 V a.c. and a nominal current not exceeding 125 A, intended for household and similar fixed installation including residential, commercial and light industrial buildings. This standard also applies to "plug-in filters". These filters (see Figure 1) are used to set a suitable impedance, in the nominal frequency range of the mains signalling system, at any point of the low voltage mains network where a low impedance equipment is connected, in order to allow reliable operation of mains signalling system. These impedance filters can be used either in utility or consumer networks. They may also be used in conjunction with incoming filters and segmentation filters.

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148.5 kHz - Low voltage decoupling filters - Impedance filter

ICS
31.160;33.040.30;97.120
CCS
K30
发布
2003-04-15
实施
2003-04-15

This standard applies to segmentation filters in a mains communication system used for single or multiphase installations having a phase to neutral voltage not exceeding 250 V a.c. and a nominal current not exceeding 125 A, intended for household and similar fixed installation including residential, commercial and light industrial buildings and utility networks. These filters (see Figure 1) are used to control the coupling of signals between two areas of a mains communication system. The standard defines · the minimum impedance in the relevant frequency range(s) at both ports, · the minimum attenuation of signals transmitted between port.

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148.5 kHz - Low voltage decoupling filters - Segmentation filter

ICS
31.160;33.040.30;97.120
CCS
M30
发布
2003-04-11
实施
2003-04-11

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 4-1: Low voltage decoupling filters; Generic specification; German version EN 50065-4-1:2001

ICS
31.160;33.040.30;97.120
CCS
K40
发布
2002-02
实施
2002-02-01

This standard applies to decoupling filters installed on the low voltage mains network and operating in the frequency range 3 kHz to 148,5 kHz on low voltage mains network. It does not apply to general purpose filters for EMI suppression. It does not apply to protocol dependant devices except physical layer (frequency). It does not apply to filters incorporated in household equipment for example: washing machines and coffee machines. It specifies the impedance and the transfer function definitions, requirements and test methods of the decoupling filter and some other requirements for example Voltage Drop, Leakage Current and Form Factor. The impedance and the transfer function are referred to the decoupling filter mains power ports (ref. Figure 1). The use of the decoupling filter is considered optional; additional rules or obligations may exist that are outside the scope of this standard. The safety requirements related to decoupling filters are not covered in this standard. They are covered in an other part of the EN 50065 set of standards

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148.5 kHz - Low voltage decoupling filters - Generic specification

ICS
31.160;33.040.30;97.120
CCS
K30
发布
2002-01-24
实施
2002-01-24



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号