35.100.20;35.160;35.240.50 标准查询与下载



共找到 57 条与 相关的标准,共 4

Industrial communication networks - Profiles - Part 5-2: Installation of fieldbuses - Installation profiles for CPF 2 (IEC 61784-5-2:2013); German version EN 61784-5-2:2013

ICS
35.100.20;35.160;35.240.50
CCS
N17
发布
2015-06
实施

Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 (IEC 61784-2:2014); English version EN 61784-2:2014, only on CD-ROM

ICS
35.100.20;35.160;35.240.50
CCS
L67
发布
2015-02
实施

This part of IEC 61784 defines a set of protocol specific communication profiles based primarily on the IEC 61158 series@ to be used in the design of devices involved in communications in factory manufacturing and process control. Each profile selects specifications for the communications protocol stack at a device. It contains a minimal set of required services at the application layer and specification of options in intermediate layers defined through references. If no application layer is included@ then a minimal set of required services at the Data-link layer is specified. The appropriate references to the protocol specific types are given in each communication profile family or associated profiles. NOTE All profiles are based on standards or draft standards or International Standards published by the IEC or from standards or International Standards established by other standards bodies or open standards processes. Each profile selects an appropriate consistent and compatible subset of services and protocols from the total available set that is defined and modeled in IEC 61158. For the selected subset of services and protocols@ the profile also describes any possible or necessary constrains in parameter values.

Industrial communication networks - Profiles - Part 1: Fieldbus profiles

ICS
35.100.20;35.160;35.240.50
CCS
N18
发布
2014-08-01
实施
2019-04-24

Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3

ICS
35.100.20;35.160;35.240.50
CCS
N18
发布
2014-07-01
实施

Industrial communication networks. Profiles. Installation of fieldbuses. Installation profiles for CPF 2

ICS
35.100.20;35.160;35.240.50
CCS
M10
发布
2014-01-31
实施
2014-01-31

Industrial communication networks - Profiles - Part 5-2: Installation of fieldbuses - Installation profiles for CPF 2 (IEC 61784-5-2:2010); German version EN 61784-5-2:2012

ICS
35.100.20;35.160;35.240.50
CCS
N17
发布
2012-11
实施
2012-11-01

Industrial communication networks. Profiles. Installation of fieldbuses. Installation profiles for CPF 2

ICS
35.100.20;35.160;35.240.50
CCS
M11
发布
2012-05-31
实施
2012-05-31

This part of IEC 61158 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term “time-critical” is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. This standard defines in an abstract way the externally visible service provided by the Type 12 fieldbus data-link layer in terms of a) the primitive actions and events of the service; b) the parameters associated with each primitive action and event, and the form which they take; c) the interrelationship between these actions and events, and their valid sequences.

Industrial communication networks — Fieldbus specifications — Part 3-12: Data-link layer service definition — Type 12 elements

ICS
35.100.20;35.160;35.240.50
CCS
L79;M10
发布
2009-02-28
实施
2009-02-28

This part of IEC 61158 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term “time-critical” is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. This standard defines in an abstract way the externally visible service provided by the Type 11 fieldbus data-link layer in terms of a) the primitive actions and events of the service; b) the parameters associated with each primitive action and event, and the form which they take; and c) the interrelationship between these actions and events, and their valid sequences. The purpose of this standard is to define the services provided to • the Type 11 fieldbus application layer at the boundary between the application and datalink layers of the fieldbus reference model, and • systems management at the boundary between the data-link layer and systems management of the fieldbus reference model. The principal objective of this standard is to specify the characteristics of conceptual data-link layer services suitable for time-critical communications, and thus supplement the OSI Basic Reference Model in guiding the development of data-link protocols for time-critical communications. A secondary objective is to provide migration paths from previously-existing industrial communications protocols. This specification may be used as the basis for formal DL-Programming-Interfaces. Nevertheless, it is not a formal programming interface, and any such interface will need to address implementation issues not covered by this specification, including a) the sizes and octet ordering of various multi-octet service parameters, and b) the correlation of paired request and confirm, or indication and response, primitives. This standard do not specify individual implementations or products, nor do they constrain the implementations of data-link entities within industrial automation systems. There is no conformance of equipment to this data-link layer service definition standard. Instead, conformance is achieved through implementation of the corresponding data-link protocol that fulfills the Type 11 data-link layer services defined in this standard.

Industrial communication networks — Fieldbus specifications — Part 3-11: Data-link layer service definition — Type 11 elements

ICS
35.100.20;35.160;35.240.50
CCS
M11
发布
2009-01-31
实施
2009-01-31

This part of IEC 61158 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term “time-critical” is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. This standard defines in an abstract way the externally visible service provided by the Type 13 fieldbus data-link layer in terms of a) the primitive actions and events of the service; b) the parameters associated with each primitive action and event, and the form which they take; and c) the interrelationship between these actions and events, and their valid sequences. The purpose of this standard is to define the services provided to ? the Type 13 fieldbus application layer at the boundary between the application and datalink layers of the fieldbus reference model, and ? systems management at the boundary between the data-link layer and systems management of the fieldbus reference model. The principal objective of this standard is to specify the characteristics of conceptual data-link layer services suitable for time-critical communications, and thus supplement the OSI Basic Reference Model in guiding the development of data-link protocols for time-critical communications. A secondary objective is to provide migration paths from previously-existing industrial communications protocols. This specification may be used as the basis for formal DL-Programming-Interfaces. Nevertheless, it is not a formal programming interface, and any such interface will need to address implementation issues not covered by this specification, including a) the sizes and octet ordering of various multi-octet service parameters, and b) the correlation of paired request and confirm, or indication and response, primitives. This standard does not specify individual implementations or products, nor do they constrain the implementations of data-link entities within industrial automation systems. There is no conformance of equipment to this data-link layer service definition standard. Instead, conformance is achieved through implementation of the corresponding data-link protocol that fulfills the Type 13 data-link layer services defined in this standard.

Industrial communication networks - Fieldbus specifications - Part 3-13: Data-link layer service definition - Type 13 elements

ICS
35.100.20;35.160;35.240.50
CCS
M11
发布
2009-01-31
实施
2009-01-31

This part of IEC 61158 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term “time-critical” is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. This standard defines in an abstract way the externally visible service provided by the Type 17 fieldbus data-link Layer in terms of a) the primitive actions and events of the service; b) the parameters associated with each primitive action and event, and the form which they take; and c) the interrelationship between these actions and events, and their valid sequences. The purpose of this standard is to define the services provided to • the Type 17 fieldbus application layer at the boundary between the application and datalink layers of the fieldbus reference model, and • systems management at the boundary between the data-link layer and systems management of the fieldbus reference model; • specifications The principal objective of this standard is to specify the characteristics of conceptual data-link layer services suitable for time-critical communications, and thus supplement the OSI Basic Reference Model in guiding the development of data-link protocols for time-critical communications. A secondary objective is to provide migration paths from previously-existing industrial communications protocols. This specification may be used as the basis for formal DL-Programming-Interfaces. Nevertheless, it is not a formal programming interface, and any such interface will need to address implementation issues not covered by this specification, including a) the sizes and octet ordering of various multi-octet service parameters, and b) the correlation of paired request and confirm, or indication and response, primitives. • Conformance This standard does not specify individual implementations or products, nor does it constrain the implementations of data-link entities within industrial automation systems. There is no conformance of equipment to this data-link layer service definition standard. Instead, conformance is achieved through implementation of the corresponding data-link protocol that fulfills the Type 17 data-link layer services defined in this standard.

Industrial communication networks — Fieldbus specifications — Part 3-17: Data-link layer service definition — Type 17 elements

ICS
35.100.20;35.160;35.240.50
CCS
L79;M10
发布
2009-01-31
实施
2009-01-31

This part of IEC 61158 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term “time-critical” is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. This standard defines in an abstract way the externally visible services provided by the Type 4 fieldbus data-link layer in terms of a) the primitive actions and events of the services; b) the parameters associated with each primitive action and event, and the form which they take; and c) the interrelationship between these actions and events, and their valid sequences. The purpose of this standard is to define the services provided to ? the Type 4 fieldbus application layer at the boundary between the application and data-link layers of the fieldbus reference model; ? systems management at the boundary between the data-link layer and systems management of the fieldbus reference model. The principal objective of this standard is to specify the characteristics of conceptual data-link layer services suitable for time-critical communications, and thus supplement the OSI Basic Reference Model in guiding the development of data-link protocols for time-critical communications. A secondary objective is to provide migration paths from previously-existing industrial communications protocols. This specification may be used as the basis for formal DL-Programming-Interfaces. Nevertheless, it is not a formal programming interface, and any such interface will need to address implementation issues not covered by this specification, including a) the sizes and octet ordering of various multi-octet service parameters; b) the correlation of paired request and confirm, or indication and response, primitives. This standard does not specify individual implementations or products, nor does it constrain the implementations of data-link entities within industrial automation systems. There is no conformance of equipment to this data-link layer service definition standard. Instead, conformance is achieved through implementation of the corresponding data-link protocol that fulfills the Type 1 data-link layer services defined in this standard.

Industrial communication networks - Fieldbus specifications - Part 3-4: Data-link layer service definition - Type 4 elements

ICS
35.100.20;35.160;35.240.50
CCS
L79;M10
发布
2009-01-31
实施
2009-01-31

This part of IEC 61158 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term “time-critical” is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. This standard defines in an abstract way the externally visible service provided by the Type 1 fieldbus data-link layer in terms of a) the primitive actions and events of the service; b) the parameters associated with each primitive action and event, and the form which they take; and c) the interrelationship between these actions and events, and their valid sequences. The purpose of this standard is to define the services provided to ? the Type 1 fieldbus application layer at the boundary between the application and data-link layers of the fieldbus reference model; ? systems management at the boundary between the data-link layer and systems management of the fieldbus reference model. The principal objective of this standard is to specify the characteristics of conceptual data-link layer services suitable for time-critical communications, and thus supplement the OSI Basic Reference Model in guiding the development of data-link protocols for time-critical communications. A secondary objective is to provide migration paths from previously existing industrial communications protocols. This specification may be used as the basis for formal DL-Programming-Interfaces. Nevertheless, it is not a formal programming interface, and any such interface will need to address implementation issues not covered by this specification, including a) the sizes and octet ordering of various multi-octet service parameters; b) the correlation of paired request and confirm, or indication and response, primitives. This standard does not specify individual implementations or products, nor does it constrain the implementations of data-link entities within industrial automation systems. There is no conformance of equipment to this data-link layer service definition standard. Instead, conformance is achieved through implementation of the corresponding data-link protocol that fulfills the Type 7 data-link layer services defined in this standard.

Industrial communication networks - Fieldbus specifications - Part 3 : Data-link layer service definition - Type 3 elements

ICS
35.100.20;35.160;35.240.50
CCS
L79;M10
发布
2009-01-31
实施
2009-01-31

This part of IEC 61158 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term “time-critical” is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. This standard defines in an abstract way the externally visible service provided by the Type 8 fieldbus data-link layer in terms of a) the primitive actions and events of the service; b) the parameters associated with each primitive action and event, and the form which they take; and c) the interrelationship between these actions and events, and their valid sequences. The purpose of this standard is to define the services provided to • the Type 8 fieldbus application layer at the boundary between the application and data-link layers of the fieldbus reference model, and • systems management at the boundary between the data-link layer and systems management of the fieldbus reference model. The principal objective of this standard is to specify the characteristics of conceptual data-link layer services suitable for time-critical communications, and thus supplement the OSI Basic Reference Model in guiding the development of data-link protocols for time-critical communications. A secondary objective is to provide migration paths from previously-existing industrial communications protocols. This specification may be used as the basis for formal DL-Programming-Interfaces. Nevertheless, it is not a formal programming interface, and any such interface will need to address implementation issues not covered by this specification, including a) the sizes and octet ordering of various multi-octet service parameters, and b) the correlation of paired request and confirm, or indication and response, primitives. This standard does not specify individual implementations or products, nor does it constrain the implementations of data-link entities within industrial automation systems. There is no conformance of equipment to this data-link layer service definition standard. Instead, conformance is achieved through implementation of the corresponding data-link protocol that fulfills the Type 8 data-link layer services defined in this standard.

Industrial communication networks — Fieldbus specifications — Part 3-8: Data-link layer service definition — Type 8 elements

ICS
35.100.20;35.160;35.240.50
CCS
M11
发布
2009-01-31
实施
2009-01-31

This part of IEC 61158 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term “time-critical” is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. This standard defines in an abstract way the externally visible service provided by the Type 14 fieldbus data-link layer in terms of a) the primitive actions and events of the service; b) the parameters associated with each primitive action and event, and the form which they take; and c) the interrelationship between these actions and events, and their valid sequences. The purpose of this standard is to define the services provided to ? the Type 14 fieldbus application layer at the boundary between the application and datalink layers of the fieldbus reference model, and ? systems management at the boundary between the data-link layer and systems management of the fieldbus reference model. The principal objective of this standard is to specify the characteristics of conceptual data-link layer services suitable for time-critical communications, and thus supplement the OSI Basic Reference Model in guiding the development of data-link protocols for time-critical communications. A secondary objective is to provide migration paths from previously-existing industrial communications protocols. This specification may be used as the basis for formal DL-Programming-Interfaces. Nevertheless, it is not a formal programming interface, and any such interface will need to address implementation issues not covered by this specification, including a) the sizes and octet ordering of various multi-octet service parameters, and b) the correlation of paired request and confirm, or indication and response, primitives. This standard do not specify individual implementations or products, nor do they constrain the implementations of data-link entities within industrial automation systems. There is no conformance of equipment to this data-link layer service definition standard. Instead, conformance is achieved through implementation of the corresponding data-link protocol that fulfills the Type 14 data-link layer services defined in this standard.

Industrial communication networks — Fieldbus specifications — Part 3-14: Data-link layer service definition — Type 14 elements

ICS
35.100.20;35.160;35.240.50
CCS
M11
发布
2009-01-31
实施
2009-01-31

This part of IEC 61158 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term “time-critical” is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. This standard defines in an abstract way the externally visible service provided by the Type 3 fieldbus data-link layer in terms of a) the primitive actions and events of the service; b) the parameters associated with each primitive action and event, and the form which they take; and c) the interrelationship between these actions and events, and their valid sequences. The purpose of this standard is to define the services provided to ? the Type 3 fieldbus application layer at the boundary between the application and data-link layers of the fieldbus reference model, and ? systems management at the boundary between the data-link layer and systems management of the fieldbus reference model. The principal objective of this standard is to specify the characteristics of conceptual data-link layer services suitable for time-critical communications, and thus supplement the OSI Basic Reference Model in guiding the development of data-link protocols for time-critical communications. A secondary objective is to provide migration paths from previously existing industrial communications protocols. This specification may be used as the basis for formal DL-Programming-Interfaces. Nevertheless, it is not a formal programming interface, and any such interface will need to address implementation issues not covered by this specification, including a) the sizes and octet ordering of various multi-octet service parameters, and b) the correlation of paired request and confirm, or indication and response, primitives. This standard does not specify individual implementations or products, nor do they constrain the implementations of data-link entities within industrial automation systems. There is no conformance of equipment to this data-link layer service definition standard. Instead, conformance is achieved through implementation of the corresponding data-link protocol that fulfills the Type 1 data-link layer services defined in this standard.

Industrial communication networks - Fieldbus specifications - Part 3-3: Data-link layer service definition - Type 3 elements

ICS
35.100.20;35.160;35.240.50
CCS
L79;M10
发布
2009-01-31
实施
2009-01-31

This part of IEC 61158 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term “time-critical” is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. This standard defines in an abstract way the externally visible service provided by the Type 7 fieldbus data-link layer in terms of a) the primitive actions and events of the service; b) the parameters associated with each primitive action and event, and the form which they take; and c) the interrelationship between these actions and events, and their valid sequences. The purpose of this standard is to define the services provided to • the Type 7 fieldbus application layer at the boundary between the application and data-link layers of the fieldbus reference model, and • systems management at the boundary between the data-link layer and systems management of the fieldbus reference model. The principal objective of this standard is to specify the characteristics of conceptual data-link layer services suitable for time-critical communications, and thus supplement the OSI Basic Reference Model in guiding the development of data-link protocols for time-critical communications. A secondary objective is to provide migration paths from previously-existing industrial communications protocols. This specification may be used as the basis for formal DL-Programming-Interfaces. Nevertheless, it is not a formal programming interface, and any such interface will need to address implementation issues not covered by this specification, including a) the sizes and octet ordering of various multi-octet service parameters, and b) the correlation of paired request and confirm, or indication and response, primitives. This standard does not specify individual implementations or products, nor does it constrain the implementations of data-link entities within industrial automation systems. There is no conformance of equipment to this data-link layer service definition standard. Instead, conformance is achieved through implementation of the corresponding data-link protocol that fulfills the Type 7 data-link layer services defined in this standard.

Industrial communication networks — Fieldbus specifications — Part 3-7: Data-link layer service definition — Type 7 elements

ICS
35.100.20;35.160;35.240.50
CCS
M10;L79
发布
2009-01-31
实施
2009-01-31

This part of IEC 61158 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term “time-critical” is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. This standard defines in an abstract way the externally visible service provided by the Type 2 fieldbus data-link layer in terms of a) the primitive actions and events of the service; b) the parameters associated with each primitive action and event, and the form which they take; and c) the interrelationship between these actions and events, and their valid sequences. The purpose of this standard is to define the services provided to: ? the Type 2 fieldbus application layer at the boundary between the application and data-link layers of the fieldbus reference model; ? systems management at the boundary between the data-link layer and systems management of the fieldbus reference model. Type 2 DL-service provides both a connected and a connectionless subset of those services specified in ISO/IEC 8886. The principal objective of this standard is to specify the characteristics of conceptual data-link layer services suitable for time-critical communications and thus supplement the OSI Basic Reference Model in guiding the development of data-link protocols for time-critical communications. A secondary objective is to provide migration paths from previously-existing industrial communications protocols. This specification may be used as the basis for formal DL-Programming-Interfaces. Nevertheless, it is not a formal programming interface, and any such interface will need to address implementation issues not covered by this specification, including: a) the sizes and octet ordering of various multi-octet service parameters; b) the correlation of paired request and confirm, or indication and response, primitives. This standard does not specify individual implementations or products, nor does it constrain the implementations of data-link entities within industrial automation systems.

Industrial communication networks - Fieldbus specifications - Part 3-2: Data-link layer service definition - Type 2 elements

ICS
35.100.20;35.160;35.240.50
CCS
L79;M10
发布
2009-01-31
实施
2009-01-31

This standard provides common elements for basic time-critical messaging communications between devices in an automation environment. The term “time-critical” is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. This standard defines in an abstract way the externally visible service provided by the Type 19 fieldbus data-link layer in terms of a) the primitive actions and events of the service; b) the parameters associated with each primitive action and event, and the form which they take; and c) the interrelationship between these actions and events, and their valid sequences. The purpose of this standard is to define the services provided to ? the Type 19 fieldbus application layer at the boundary between the application and datalink layers of the fieldbus reference model, and ? systems management at the boundary between the data-link layer and systems management of the fieldbus reference model. The principal objective of this standard is to specify the characteristics of conceptual data-link layer services suitable for time-critical communications, and thus supplement the OSI Basic Reference Model in guiding the development of data-link protocols for time-critical communications. A secondary objective is to provide migration paths from previously-existing industrial communications protocols. This standard may be used as the basis for formal DL-Programming-Interfaces. Nevertheless, it is not a formal programming interface, and any such interface will need to address implementation issues not covered by this specification, including: a) the sizes and octet ordering of various multi-octet service parameters, and b) the correlation of paired request and confirm, or indication and response, primitives. This standard does not specify individual implementations or products, nor do they constrain the implementations of data-link entities within industrial automation systems. There is no conformance of equipment to this data-link layer service definition standard. Instead, conformance is achieved through implementation of the corresponding data-link protocol that fulfills the Type 19 data-link layer services defined in this standard.

Industrial communication networks - Fieldbus specifications - Data-link layer service definition - Type 19 elements

ICS
35.100.20;35.160;35.240.50
CCS
L79;M10
发布
2009-01-31
实施
2009-01-31

1.1 Overview This part of IEC 61158 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term “time-critical” is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. This standard defines in an abstract way the externally visible service provided by the Type 8 fieldbus data-link layer in terms of a) the primitive actions and events of the service; b) the parameters associated with each primitive action and event, and the form which they take; and c) the interrelationship between these actions and events, and their valid sequences. The purpose of this standard is to define the services provided to • the Type 8 fieldbus application layer at the boundary between the application and data-link layers of the fieldbus reference model, and • systems management at the boundary between the data-link layer and systems management of the fieldbus reference model. 1.2 Specifications The principal objective of this standard is to specify the characteristics of conceptual data-link layer services suitable for time-critical communications, and thus supplement the OSI Basic Reference Model in guiding the development of data-link protocols for time-critical communications. A secondary objective is to provide migration paths from previously-existing industrial communications protocols. This specification may be used as the basis for formal DL-Programming-Interfaces. Nevertheless, it is not a formal programming interface, and any such interface will need to address implementation issues not covered by this specification, including a) the sizes and octet ordering of various multi-octet service parameters, and b) the correlation of paired request and confirm, or indication and response, primitives. 1.3 Conformance This standard does not specify individual implementations or products, nor does it constrain the implementations of data-link entities within industrial automation systems. There is no conformance of equipment to this data-link layer service definition standard. Instead, conformance is achieved through implementation of the corresponding data-link protocol that fulfills the Type 8 data-link layer services defined in this standard.

Industrial communication networks - Fieldbus specifications - Part 3-8: Data-link layer service definition - Type 8 elements (IEC 61158-3-8:2007); English version EN 61158-3-8:2008, only on CD-ROM

ICS
35.100.20;35.160;35.240.50
CCS
N18;P76
发布
2008-09
实施
2008-09-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号