This European Standard specifies safety, health and functional requirements for 12 V direct current (DC) extra low voltage (ELV) electrical installations for habitation aspects of motor caravans. It applies only to installations which are electrically connected with the electrical installation of the base vehicle or which can be electrically connected with it by means of change-over devices. This European Standard also specifies the ELV output requirements of low voltage (LV) equipment that may be used to provide an ELV supply but it does not specify safety, technical and functional requirements for LV appliances and installations. Requirements for LV installations are specified in HD 60364-7-721.
Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations - Part 2: Motor caravans; German version EN 1648-2:2018
This European Standard specifies safety, health and functional requirements for 12 V direct current (DC) extra low voltage (ELV) electrical installations for habitation aspects of caravans. It covers the design and integration of the caravan system with the towing vehicle system. It does not apply to commercial trailers; nor does it include requirements for ELV road lighting and signalling lamps and their installations, except for safety requirements for the routing of cables in LPG storage compartments. This European Standard also specifies the ELV output requirements of low voltage (LV) equipment that may be used to provide an ELV supply but it does not specify safety, technical and functional requirements for LV appliances and installations. Requirements for LV installations are specified in HD 60364-7-721.
Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations - Part 1: Caravans; German version EN 1648-1:2018
Leisure accommodation vehicles. 12 V direct current extra low voltage electrical installations. Motor caravans
Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations - Part 1: Caravans
Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations - Part 2: Motor caravans
Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations - Part 2: Motor caravans; German version EN 1648-2:2012
Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations - Part 2 : motor caravans.
Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations - Part 1 : caravans.
Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations - Part 1: Caravans; German version EN 1648-1:2012
Leisure accommodation vehicles. 12 V direct current extra low voltage electrical installations. Caravans
Leisure accommodation vehicles. 12 V direct current extra low voltage electrical installations. Motor caravans
This European Standard specifies safety, health and functional requirements for 12 V direct current (DC) extra low voltage (ELV) electrical installations for habitation aspects of motor caravans. It applies only to installations which are electrically connected with the electrical installation of the base vehicle or which can be electrically connected with it by means of change-over devices. This European Standard also specifies the ELV output requirements of low voltage (LV) equipment that may be used to provide an ELV supply but it does not specify safety, technical and functional requirements for LV appliances and installations. Requirements for LV installations are specified in HD 60364-7-721.
Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations - Part 2: Motor caravans
This document specifies safety, health and functional requirements for 12 V direct current (DC) extra low voltage (ELV) electrical installations for habitation aspects of motor caravans. It applies only to installations which are electrically connected with the electrical installation of the base vehicle or which can be electrically connected with it by means of change-over devices. This document also specifies the ELV output requirements of low voltage (LV) equipment that may be used to provide an ELV supply but it does not specify safety, technical and functional requirements for LV appliances and installations. Requirements for LV installations are specified in HD 384-7-708 S1.
Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations - Motor caravans
This document specifies safety, health and functional requirements for 12V direct current (DC) extra low voltage (ELV) electrical installations for habitation aspects of caravans. It covers the design and integration of the caravan system with the towing vehicle system. It does not apply to commercial trailers, nor does it include requirements for ELV road lighting and signalling lamps and their installations, except for safety requirements for the routing of cables in LPG storage compartments. This document also specifies the ELV output requirements of low voltage (LV) equipment that may be used to provide an ELV supply but it does not specify safety, technical and functional requirements for LV appliances and installations. Requirements for LV installations are specified in HD 384-7-708.S1.
Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations - Caravans
This document specifies safety, health and functional requirements for 12V direct current (DC) extra low voltage (ELV) electrical installations for habitation aspects of caravans. It covers the design and integration of the caravan system with the towing vehicle system. It does not apply to commercial trailers, nor does it include requirements for ELV road lighting and signalling lamps and their installations, except for safety requirements for the routing of cables in LPG storage compartments. This document also specifies the ELV output requirements of low voltage (LV) equipment that may be used to provide an ELV supply but it does not specify safety, technical and functional requirements for LV appliances and installations. Requirements for LV installations are specified in HD 384-7-708.S1.
Leisure accommodation vehicles-12 V direct current extra low voltage electrical installations-Part 1:Caravans
Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations - Part 1 : caravans.
Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations - Part 2 : motor caravans.
Leisure accomodation vehicles. 12 V direct current extra low voltage electrical installations. Part 1 : caravans.
Leisure accomodation vehicles. 12 V direct current extra low voltage electrical installations. Part 2 : motor caravans.
Specifies safety and functional requirements for 12 V installations and includes an annex that gives means of determining the minimum cross-sectional area of cables. Does not apply the commercial trailers or motor caravans, nor does it include requirements for ELV road lighting and signalling lamps and their installations.