北京华瑞森科技发展有限公司 致力于核辐射检测仪器及辐射防护用品、辐射监测系统工程、射线防护材料、远红外线发射率检测仪器、 核医学仪器(井型NaI咖玛计数仪、多功能核放射性检测仪、活度计,个人剂量报警仪,Xγαβ辐射仪等)、医疗器械、实验仪器、环保核辐射仪器设备等研发销售,我们以科学严谨的工作态度,服务于科研、医疗教育、环保、检验检疫、疾控中心、军警、安防等诸多行业,服务于社会。...

Model 870 mA/mAs Meter With exposure time measurement

上一篇 / 下一篇  2011-06-15 10:17:34

Model 870 mA/mAs Meter With exposure time measurement

 

FEATURES

 Small hand held size

 Measure current from any x-ray

 Single phase

 Full wave

 Multiphase

 DC

 New High Accuracy Circuit

 Self-Resetting

Battery Operated

 Two Year Warranty

 Built in measurement of battery

 Use for Medical or Dental X-rays

 Use for digital x-ray

 Displays mA, mAs and exposure time for each reading

 Easy to use

 

DESCRIPTION

Measures tube current of x-ray generators.

 Calculates product of exposure time and mA for mAs.

 Connect two leads in series with tube current.

 Exposure time is measured in milliseconds.

 New improved circuit increases accuracy, reliability

 Provides automatic detection of AC / DC

 Eliminates need to reset.

 Stores and displays mA minimizing need for long x-ray exposure.

 Displays all information eliminating need for multiple exposures.

 

TYPICAL APPLICATIONS

 Check x-ray tube filament emission by measuring mAs value of exposure

 Check and adjust mA settings

 Verification of x-ray exposure time

 Calibration of x-ray timer

 Quality Assurance

 Measurement of exposure time

 Analyze x-ray malfunctions

 

SPECIFICATIONS FOR MODEL 870 mA / mAs METER

 

RANGE

200 mA Full Scale

0.1 mA Resolution (mA or mAs)

10 Ohms Input impedance

Measures 5 to 200 mA

2A Full Scale

1 mA Resolution (mA or mAs)

1 Ohm Input impedance

Meter automatically selects AC/DC

Select range via On / Off Switch

 

mA / mAs ACCURACY

1% +/- 2 mA on all ranges

 

CONNECTION

Tip Jacks

Test leads with two alligator clips

 

RECALIBRATION

Annually

 

OPERATING CONDITIONS

+10o to 40o C

50o to 104o F

 

 

KVp / mAs Meter And  Exposure Time Meter

Model 820 / Low Range 820L

 

 

FEATURES

Combines two instruments

KVp and mAs in one package

Easy to use

No need to set for AC/DC

mAs meter is self-resetting

mA is stored permitting short exposures

kVp is noninvasive

AC or DC x-rays

High accuracy

Measures kVp, mA, mAS, exposure time

Battery operated

Two year warranty

Custom carrying case option

Solid state digital design

Durable ABS plastic case

 

DESCRIPTION

Use as mAs Meter or kVp Meter

mA and mAs measure x-ray tube

current

KVp measures the peak x-ray

accelerating voltage from tungsten xray

generators.

Direct Measurement of peak kV from

the x-ray head, simply place 820(L) in

beam and take x-ray.

Push Mode button to display Exposure

Time.

Indicates x-ray waveform. type - e.g.

Half-wave, Full-wave or DC / 3 Phase.

Optimized for Dental x-rays, also works

on radiographic and fluoroscopic xrays.

Large display readable from outside

x-ray room.

Alphanumeric display provides easy to

understand status and error messages.

Plug in mAs cable to measure mA and

mAs.

Remove mAs cable to measure kVp

 

TYPICAL APPLICATIONS

Verification of peak x-ray voltage

Constancy checks

Calibration of x-ray

Quality assurance

Measurement of exposure time

Half value layer determination

Troubleshooting and repair of x-rays

Maintain quality of x-ray

 

SPECIFICATIONS FOR 820/820L kVp

RANGE

820: 45 to 125Kv

820L: 40 to 115Kv

KVP ACCURACY

2% +/- 1 kV, at 25 to 100 mA (820)

or 10 to 50 mA (820L) both

18 to 42 cm from head, for Tungsten

target x-ray tube with 1.5 mm Aluminum

equivalent filtration.

EXPOSURE TIME ACCURACY

1% +/- 2 millisecond (1/5 to 2 sec)

Minimum exposure time is 100

millisecond

MINIMUM EXPOSURE TIME

100 millisec -High Speed Mode

200 millisec -High Resolution Mode

MINIMUM CURRENT (mA)

7 mA (820) or 5 mA (820L) at 50 kV,

10 cm from x-ray, depending on focus

 

SPECIFICATIONS FOR 820/820L mAs

RANGE

200 mA Full Scale

0.1 mA Resolution (mA or mAs)

10 Ohms Input impedance

2A Full Scale

1 mA Resolution (mA or mAs)

1 Ohm Input impedance

Meter automatically selects AC/DC

Set Range via pushbutton switch

mAs ACCURACY

2% +/- 1 mA on both ranges

CONNECTION

Via 1 meter cable with two alligator

clips

 

ORDERING INFORMATION

Model 820 X-ray kVp /mAs / Exposure Time

Meter

Model 820L Low Range X-ray kVp / mAs /

Exposure Time Meter

Please note that the Model 815 X-ray

kVp/Exposure Time Meter is still available.

 

GENERAL SPECIFICATIONS

DISPLAY

0.4" (10.2mm) Liquid Crystal

8 Character Alphanumeric

CONTROLS/INDICATORS

ON/OFF Switch – Illuminated

push-button with green

power-on indication

MODE Switch - momentary

push-button

8 Character Liquid Crystal Display

No connections needed for kVp

measurement

POWER

4 AA batteries accessible from

bottom of case

Low battery indicator

BATTERY LIFE

48 hours continuous

Typically 9 months of normal use

WARRANTY

2 years from ship date

PHYSICAL SIZE

150 X 120 X 58.5 mm

5.9 X 4.7 X 2.3 inches

WEIGHT

0.7 kg, (1.5 lb)

 

 

 

Contact We:

 

Huaruison Science and Technology Development Co., Ltd.

AddressNo.16 guanghuaRoad,Tongzhou Development Zone Beijing 10100,P.R.China

Phone:0086-10-51266093QQ:1275041125

Fax:0086-10-51266093

E-mailhuaruison@yahoo.com.hk

http://www.huaruison.com

http://www.eccxray.com/zhongkao.html

http://www.xraytest.cn

 


TAG: exposuremetermodeltime870withmeasurement

 

评分:0

我来说两句

显示全部

:loveliness::handshake:victory::funk::time::kiss::call::hug::lol:'(:Q:L;P:$:P:o:@:D:(:)

Open Toolbar