400-6699-117转1000
您好,欢迎您查看分析测试百科网,请问有什么帮助您的?
分析测试百科网 认证会员,请放心拨打!
参考报价: | 面议 | 型号: | VCU |
品牌: | 哈佛仪器 | 产地: | 美国 |
关注度: | 7 | 信息完整度: | |
样本: | 典型用户: | 暂无 | |
供应商性质 | 生产商 | 产地类别 | 进口 |
400-6699-117转1000
电子颅脑损伤仪(ecc
电子大脑皮质挫伤撞击仪( electric Cortical Contusion Impactor)主要针对脑皮质挫伤模型是神经损伤研究
机构最受欢迎的损伤模型制作工具。动物平台可以和驽种立体定位仪掊配使用。
由vCU大学设计制作的电子大脑皮质挫伤撞击仪,主要针对脑皮质挫伤模型。其组件有:坚固的铝架
物平台、撞击控制器和撞击头。动物平台可以和督种立体定位仪掊配使用。由高级线性马达驱动的撞击
可以由控制器来控制撞击参数,实现不同程度的损伤。撞击头含有感应器,可以确定谏率、撞击深度
与传統 Feeney's自由落体硬膜外撞击方法相比有以下优点可精确连续地控制撞击速度并获得实际撞击深
度和停留时间等参数而非重量差异很大的撞击。可精确重复制作挫伤损伤模型减少动物死亡,使实验过程
更加直观,可控
Celectric Cortical Contusion Impactor
The eccl is constructed with a sturdy aluminum frame to maximize rigidity, thereby ensuring impact
accuracy. The support base, animal platform and impactor head are anodized to prevent oxidation and
assure equipment longevity
Product assembly includes the base and support frame, and adjustable animal positioner with an
aluminum animal platform to be used in conjunction with a variety of stereotactic mounts. This model
utilizes the enhanced linier motor driven impactor and controller. The enhanced impact head also houses
a photo-optic sensor to determine velocity, impact depth and dwell, and is extremely reproducible.
细胞颅脑损伤仪(cIc
2cell Injury Controller ll
缩气体送到每个 culture wells,以造成培养组织牵张性的损伤,损伤的严重程度是依据气体在密闭的
culture wel进出的量,细胞损伤控制仪(CC是可以搭配Fex@29.45cm2 culturing trays I(针对vcU早期
的细胞损伤控制仪和BiFe5775cm2 culturing trays。因为根据所採用的纽胞种羹、损伤的程度、培
的狀况,受损后的细胞或许会因为上述因素死掉或要修护,所以∨CU的细胞损伤控制仪(CC)很適合应
用在下列领域细胞受损、修护,死亡,药物介入的反应
Depending on the cell type, the degree of injury and the culture conditions, the injured cells may die
epair. Therefore, the system can be employed to study the responses to trauma, including cell injury
epair, death or pharmacologic intervention
The CIC ll has been designed for use with a patented, commercially available tissue culture system from
Flexcell Intemational Corp in Hillsborough, N.C. Tissue cultures are grown in culturing wells with
stretchable Silastic membrane bottoms. The CIC ll regulates the flow of compressed gas to rapidly
pressurize individual culture wells, causing a radial stretch injury to the culture. Injury severity is
ermined by controlling t
gas in and out of the sealed culture well and the peak pressure
captured to provide an accurate indicator of radial stretch
The CIC ll accepts both the Flex l@ 29.45cm2 culturing trays, which were used with the earlier CIC
Model 94A, and the BioFlex@e 57.75cm2 culturing trays
动物颅脑损伤仪VCU信息由香港友诚生物科技有限公司为您提供,如您想了解更多关于动物颅脑损伤仪VCU报价、型号、参数等信息,欢迎来电或留言咨询。
注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途