您好,欢迎您查看分析测试百科网,请问有什么帮助您的?

稍后再说 立即咨询
福禄克测试仪器(上海)有限公司
400-6699-117转1000
热门搜索:
分析测试百科网 > 福禄克 > 压力检定和校准 > 福禄克 Fluke 712B RTD Calibrator

福禄克 Fluke 712B RTD Calibrator

参考报价: 面议 型号: Fluke 712B RTD Calibrator
品牌: 福禄克 产地: 北京
关注度: 276 信息完整度:
样本: 典型用户: 暂无
仪器种类压力校验仪应用场景便携
咨询留言 在线咨询

400-6699-1171000

AI问答
可以做哪些实验,检测什么? 可以用哪些耗材和试剂?

For the temperature calibration professional that wants a highly accurate, easy-to-use, single function RTD temperature calibrator the Fluke 712B is the ideal test tool.

Features at a Glance

  • The 712B can measure and simulate (13) different RTD types and resistance

  • Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal Hanging tool designed in and included with every unit

  • Configurable 0 % and 100 % source settings for quick 25 % linearity checks

  • Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings

  • Dual inputs and backlit display for easy interpretation of measurements

  • Power down settings remembered at power up for easy restart of tests

  • 1-year and 2-year specifications and traceable certification of calibration

DC mA Measurement
Resolution0-24 mA
Range0.001 mA
Accuracy (% of reading + counts)0.010% + 2 μA
Temperature coefficient± (0.002% of reading + 0.002% of range) /°C ( <18 °C or >28 °C)
Ohms Measurement
Ohms rangeAccuracy (% of reading +counts)
0.00 Ω to 400.00 Ω0.015% + 0.05 Ω
400.0 Ω to 4000.0 Ω0.015% + 0.5 Ω
Note: Read accuracy is based on 4-wire input. For 3-wire ohm measurements, assuming all three leads are matched, add 0.05 Ω (0.00 Ω~400.00 Ω), 0.2 Ω (400.0 Ω~4000.0 Ω) to the specifications.
Temperature coefficient± (0.002% of reading + 0.002% of range) /°C ( <18 °C or >28 °C)
Ohms Source
Ohms range1.0 Ω to 400.0 Ω
1.00 Ω to 400.00 Ω
400.0 Ω to 1500.0 Ω
1500.0 Ω to 4000.0 Ω
Excitation current from measurement device0.1 mA to 0.5 mA
0.5 mA to 3 mA
0.05 mA to 0.8 mA
0.05 mA to 0.4 mA
Accuracy (% of reading + counts)0.015% + 0.1 Ω
0.015% + 0.05 Ω
0.015% + 0.5 Ω
0.015% + 0.5 Ω
Resolution0.00 Ω to 400.00 Ω0.01 Ω
400.0 Ω to 4000.0 Ω0.1 Ω
Temperature coefficient± (0.002% of reading + 0.002% of range) /°C ( <18 °C or >28 °C)
Supports pulsed transmitters and PLCs with pulse times as short as 5 ms
RTD Input and Output
RTD Type (α)Range (°C)Measure (°C)Source (°C)
1-year2-yearSource current1-year2-year
10Ω Pt(385)-200 to 100 °C1.5 °C3 °C1 mA1.5 °C3 °C
100 to 800 °C1.8 °C3.6 °C1 mA1.8 °C3.6 °C
50Ω Pt(385)-200 to 100 °C0.4 °C0.7 °C1 mA0.4 °C0.7 °C
100 to 800 °C0.5 °C0.8 °C1 mA0.5 °C0.8 °C
100 Ω Pt(385)-200 to 100 °C0.2 °C0.4 °C1 mA0.2 °C0.4 °C
100 to 800 °C0.015% 
+0.18 °C
0.03%
+0.36 °C
1 mA0.015%
+0.18 °C
0.03%
+0.36 °C

200 Ω Pt(385)-200 to 100 °C0.2 °C0.4 °C500 μA0.2 °C0.4 °C
100 to 630 °C0.015%
+0.18 °C
0.03%
+0.36 °C
500 μA0.015%
+0.18 °C
0.03%
+0.36 °C

500 Ω Pt(385)-200 to 100 °C0.3 °C0.6 °C250 μA0.3 °C0.6 °C
100 to 630 °C0.015%
+0.28 °C
0.03% 
+0.56 °C
250 μA0.015%
+0.28 °C
0.03% 
+0.56 °C

1000 Ω Pt(385)-200 to 100 °C0.2 °C0.4 °C250 μA0.2 °C0.4 °C
100 to 630 °C0.015%
+0.18 °C
0.03%
+0.36 °C
250 μA0.015%
+0.18 °C
0.03%
+0.36 °C

100 Ω Pt(3916)-200 to 100 °C0.2 °C0.4 °C1 mA0.2 °C0.4 °C
100 to 630 °C0.015%
+0.18 °C
0.03%
+0.36 °C
1 mA0.015%
+0.18 °C
0.03%
+0.36 °C

100 Ω Pt(3926)-200 to 100 °C0.2 °C0.4 °C1 mA0.2 °C0.4 °C
100 to 630 °C0.015%
+0.18 °C
0.03%
+0.36 °C
1 mA0.015%
+0.18 °C
0.03%
+0.36 °C

10 Ω Cu(427)-100 to 260 °C1.5 °C3 °C1 mA1.5 °C3 °C
120 Ω Ni(672)-80 to 260 °C0.15 °C0.3 °C1 mA0.15 °C0.3 °C
50 Ω Cu(427)-180 to 200 °C0.4 °C0.7 °C1 mA0.4 °C0.7 °C
100 Ω Cu(427)-180 to 200 °C0.2 °C0.4 °C1 mA0.2 °C0.4 °C
YSI40015 to 50 °C0.2 °C0.4 °C250 μA0.2 °C0.4 °C
  1. Sensor inaccuracies not included.

  2. Resolution: 0.1 °C.

  3. Read accuracy is based on 4-wire input. For 3-wire RTD measurements, assuming all three RTD leads are matched, add 1.0 °C (Pt10 and Cu10), 0.6 °C (Pt50 and Cu50), 0.4 °C (Other RTD types) to the specifications.

  4. Source Accuracy in source mode is based on 0.5 mA~3 mA (1.00 Ω~400.00 Ω), 0.05 mA~0.8 mA (400.0 Ω~1500.0 Ω), 0.05 mA~0.4 mA (1500.0 Ω ~4000.0 Ω), excitation current (0.25 mA for Pt1000 range).

  5. Temperature Coefficient: ±0.05 °C /°C for measure, ± 0.05 °C /°C (<18 °C or >28 °C) for source.

  6. Supports pulsed transmitters and PLCs with pulse times as short as 5 ms.


General Specifications
Maximum voltage applied between any terminal and earth ground or between any two terminals30 V
Operating temperature-10 °C to 50 °C
Storage temperature-30 °C to 60 °C
Operating altitude2,000 meters
Storage altitude12,000 meters
Relative humidity (% RH operating without condensation)Non condensing
90% (10 °C to 30 °C)
75% (30 °C to 40 °C)
45% (40 °C to 50 °C)
(Without condensation)
Vibration requirementsMIL-T-28800E, Class 2
Drop text requirements1 meter
IP RatingIEC 60529: IP52
Electromagnetic environmentIEC 61326-1, Portable
SafetyIEC 61010-1, Max 30 V to earth, Pollution Degree 2
Power supply4 AA NEDA 1.5A IEC LR6 batteries
Size (H x W x L)52.5 mm x 84 mm x 188.5 mm
Weight515 g


福禄克 Fluke 712B RTD Calibrator信息由福禄克测试仪器(上海)有限公司为您提供,如您想了解更多关于福禄克 Fluke 712B RTD Calibrator报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途

移动版: 资讯 直播 仪器谱

Copyright ©2007-2024 ANTPEDIA, All Rights Reserved

京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号