您好,欢迎您查看分析测试百科网,请问有什么帮助您的?

稍后再说 立即咨询
奥谱天成(厦门)光电有限公司
400-6699-117转1000
热门搜索:
分析测试百科网 > 奥谱天成 > 便携式 > 奥谱天成 ATR2110 便携式拉曼光谱仪 用于制药工程

奥谱天成 ATR2110 便携式拉曼光谱仪 用于制药工程

参考报价: ¥98000 RMB(人民币) 型号: ATR2110
品牌: 奥谱天成 产地: 福建
关注度: 752 信息完整度:
样本: 典型用户: 暂无
价格范围¥5万-10万应用场景便携台式
光谱重复性<0.5cm-1最低波数250 cm-1
光谱范围250-2700 cm-1空间分辨率 横向1um,纵向1um
光谱分辨率 6cm-1仪器种类便携/手持式拉曼光谱仪
咨询留言 在线咨询

400-6699-1171000

AI问答
可以做哪些实验,检测什么? 可以用哪些耗材和试剂?

生物制药是指运用微生物学、生物学、医学、生物化学等的研究成果,从生物体、生物组织、细胞、器官、体液等,综合利用微生物学、化学、生物化学、生物技术、药学等科学的原理和方法制造的一类用于预防、治疗和诊断的制品。

GENERALDESCRIPTION

ATR2110 portable Ramanspectrometer is suitable for field operation. The outstanding reliability makesthe detection result much accurate. The excellent low stray light conditionsthat enable the spectrometer has a wide range of application, especially in thebiochemical analyzer, food safety, pharmaceutical engineering. Themulti-function software facilitated the spectral analysis process inapplication. The remote experiment through internet access makes the bald testitem much easier.

FEATURES

  • linear CCD with TEC cooling;

  • low noise circuit;

  • Powerful embedded software;

  • Fluorescent background eliminate;

  • Peak searching and indicating;

  • 10.1’’ LCD;

  • Android Operation System;

  • USB 2.0;

  • Touch screen  and Keyboard input;

  • Friendly HMI;

  • Battery Endurance > 5 hours;

  • Remote control via LAN;

  • IP67 case;


    APPLICATIONS

  • Biological science

  • Pharmaceuticalengineering

  • Forensic analysis

  • Agriculture and food safety

  • Gemstone

  • Environmentalscience

ATR2110 System


Interface

USB 2.0/LAN

Spectral region

250-2700 cm-1

Spectral resolution

6cm-1  (按美国国标方法测定)

Signal-to-Noise

>400:1 (918 cm-1 of Acetonitrile,10s accumulation, 200mW)

Exciting Laser


Center Wavelength

785nm (+/-1nm)

FWHM

0.1 nm

Output power

≥450 mW


High Reliability

  Figure 3.1 and Figure 3.2 showed thetemperature reliability testing results of fives ATR2110 portable Ramanspectrometers. The testing temperature range was from 5 oC to 40 oC.The spectrometer was kept more than 1 hour at every temperature spots.Acetonitrile was used as the standard sample in the testing. The testingresults were calculated using 918 cm-1 of acetonitrile. Thewavenumber shift was 1 cm-1 or less(as show in Fig. 3.1). The peakintensity variation was less than 10% (as show in Fig. 4).


Temperature range: 5-40 centigradeWavenumber shift: < 1 cm-1

Fig. 3.1 Wavenumber shift results testing from 5 oC to 40oC of fives ATR2110 portable Raman spectrometers

 

Temperature range: 5-40 centigrade

Spectral intensity variation: < 10%

Fig.3.2 Intensity variation testing from 5 oC to 40 oC offives ATR2110 portable Raman spectrometers

4 订购信息

型号波长(nm)功率(mW)波数范围cm-1ATR2110-473473100150-4000ATR2110-532532100150-4000ATR2110-785-27785600250-2700ATR2110-785-40150-4000ATR2110-830830600150-4000ATR2110-10641064600150-4000其他波长可定制


奥谱天成 ATR2110 便携式拉曼光谱仪 用于制药工程信息由奥谱天成(厦门)光电有限公司为您提供,如您想了解更多关于奥谱天成 ATR2110 便携式拉曼光谱仪 用于制药工程报价、型号、参数等信息,欢迎来电或留言咨询。