规格


Per 10-inch Cartridge
Filtration Area
Single Layer0.8 m²
Double Layer0.69 m²
Materials of Construction
ChemistryMixed Cellulose Esters (MCE)
Support MaterialPolyester
Device MaterialPolypropylene
Seal MaterialSilicone (SI)
Maximum Differential Pressure, bar (psid)3.5 bar (50 psid) @ 25 °C
Gravimetric Extractables
Standard Milligard® MediaThe extractables level was equal to or less than 50 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Low Protein Binding Milligard® Media, 0.2 µmThe extractables level was equal to or less than 100 mg per 10-inch cartridge after a 5 L flush and 24 hours in water at controlled room temperature.
Low Protein Binding Milligard® Media, 0.5 µmThe extractables level was equal to or less than 100 mg per 10-inch cartridge after a 5 L flush and 24 hours in water at controlled room temperature.
Low Protein Binding Milligard® Media, 1.2 µmThe extractables level was equal to or less than 250 mg per 10-inch cartridge after a 5 L flush and 24 hours in water at controlled room temperature.
Low Protein Binding Milligard® Media, 1.2/0.5 µmThe extractables level was equal to or less than 200 mg per 10-inch cartridge after a 5 L flush and 24 hours in water at controlled room temperature.
Low Protein Binding Milligard® Media, 1.2/0.5 µmThe extractables level was equal to or less than 350 mg per 10-inch cartridge after a 5 L flush and 24 hours in water at controlled room temperature.
Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
Sterilization10 autoclave cycles or SIP @ 121 °C for 30 min
Component Material ToxicityComponent materials meet the criteria of the USP <88> Reactivity Test for Class VI Plastics. These products meet the requirements of the USP <88> Safety Test, utilizing a 0.9% sodium chloride extraction.
Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Non-Fiber ReleasingComponent materials meet the “non-fiber releasing“ criteria as defined in 21 CFR 210.3 (b) (6).
Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.

Typical Clean Water Flow Rate vs Pressure Drop

Cartridge Legends Refer to Pore Size (nominal):
Milligard Media
CW03 = 0.2 µm
CW06 = 0.5 µm
CW19 = 1.2 µm
CWSC = 1.2/0.5 µm
CWSS = 0.5/0.2 µm
Milligard LPB Media
CWL3 = 0.2 µm
CWL6 = 0.5 µm
CWL9 = 1.2 µm
CWLC = 1.2/0.5 µm
CWLS = 0.5/0.2 µm


Cartridges with Milligard Media - 30-inch, Cartridge Code 0

Cartridges with Milligard Media - 30-inch, Cartridge Code 0

 


Cartridge with Milligard LPB Media - 30-inch, Cartridge Code 0

Cartridge with Milligard LPB Media - 30-inch, Cartridge Code 0