X
您需要的产品资料:
选型配置
产品样品
使用说明
应用方案
公司录用
其他
个人信息:
提交

您好,欢迎您查看分析测试百科网,请问有什么帮助您的?

稍后再说 立即咨询
您现在所在的位置:首页 >> 仪器导购 >> 分子荧光光谱/荧光分光光度计>> HORIBA Ratio Master荧光比率显微测量系统

HORIBA Ratio Master荧光比率显微测量系统

tel: 400-6699-117 6216

堀场HORIBA分子荧光光谱/荧光分光光度计, 可以在毫秒范围内测量动态荧光比率。zl的DeltaRAMTM单色仪照明系统,实现波长切换速度<2ms,配合高速检测器,可......

在线客服



Lamp Specifications

Lamp Power Supply

PTI RatioMaster lamp power supplies are highly-regulated DC units that provides very stable power for xenon, mercury, and mercury/xenon compact arc lamps as well as tungsten-halogen lamps.

Lamp power capacity75 to 200 watts
Height100 mm (3.9 inches)
Width100 mm (3.9 inches)
Length210 mm (8.3 inches)
Weight1.9 kg (4.2 pounds)
Window diameter (D)65 mm

DeltaRAM X™ Random Access Monochromator

PTI RatioMaster's exciting new DeltaRAM X™ represents the next bold step in the evolution of light sources. The compact, proprietary (patented) single monochromator design permits the selection of any single wavelength in two milliseconds or less. It is ideally suited for multi-wavelength applications as well as excitation scanning. It is easily controlled via a single low voltage signal line. Includes a 2-meter liquid light guide, for use with most microscopes and other sample handling devices. DeltaRAM X™ delivers powerful excitation wavelength from 250–650 nm under synch-lock computer control. Synch-lock control, locks the DeltaRAM X™ monochromator to the camera exposure or frame readout. The DeltaRAM X™ saves you money by not requiring purchase of additional excitation filters for each dye you wish to use. Synch-lock allows accurate timing to be retained between camera and illuminator.

Systems not synch-locked can be plagued with synchronization problems or latency due to operating events or user clicking events. Try this in another imaging software package, click and drag a window, either the illuminator will stop moving, or images will stop being acquired until the mouse button is released. This does not happen with PTI RatioMaster's sync lock!

Excitation wavelength range250–650 nm
Optimum scanning range290–610 nm
Wavelength selection speed< 2 milliseconds point-to-point
Resolution< 1 nm
Accuracy+ 3/-1 nm
Wavelength bandwidthAdjustable from 0–24 nm
Stray light rejection> 104
Light delivery0.5 meter quartz fiber optic bundle
Liquid light guide2 meter length 2 mm core diameter
Microscope adapterUser specified

Liquid Light Guide

Spectral Transmission Curves

Specific Properties

SeriesDia.PropertiesRecommended Light SourcesApplicationsTemp Range
3002, 3 ,5 mmSuperior transmission of up to 5 W of UV radiation. Suitable for rugged environmentsHg and Xe short arc, Tungsten HalogenUV Epoxy curing and fluorescence inspection, at lengths up to 20 meters.-5 to +35°C
3802, 3, 5 mmExcellent transmission from NUV to far red, at lengths to 30 m. Suitable for rugged environmentsXe short arc, Tungsten Halogen, Metal HalideOutstanding white light illumination-5 to +35°C
20002, 3, 5 mmTransmission of high power NIR in the multi-watt range. Protection required from high power radiation below 420 nm. Integrated long pass dichroic filters availableXe short arc, Tungsten Halogen, Nd-YAG or diode lasersVisible or NIR illumination at lengths to 10 meters+5 to +35°C
8005 mmEnhanced flexibility, no losses even with small bend radius. Protection required from high-powered radiation below 420 nm. Integrated long pass dichroic filters availableTungsten Halogen, Xe short arcVery High NA white light illumination, excitation of HPD in medicine.+5 to +35°C

 

Mechanical Dimensional Information

Core DiameterD1D2D3L1L2
2 mm4 mm8 mm5.5 mm6.7 mm20 mm
3 mm5 mm9 mm7 mm20 mm24 mm
5 mm7 mm10 mm9.5 mm20 mm24 mm

Photometer

When you need to perform microscope photometry, what do you use? Most labs end up acquiring some microscope accessory intended for another purpose—such as photography.

Unfortunately, these devices are rarely up for the task. Microscope photometry requires absolute light-tightness. It also helps to have a device designed to accommodate a photomultiplier housing—or even two. Additionally, it should hold filters, have an adjustable iris, and provide a means to view the image being measured.

Our microscope photometers do all of this—and more. They are specifically designed for sensitive photometric measurements. And they couple easily to virtually any popular microscope.

The Model D-104B is a single-channel photometer. The D-104C is a dual-channel photometer that allows simultaneous measurements at two different wavelengths via a dichroic cube.

No system is complete without an analog/digital photon counting detector. In order to complete a PTI RatioMaster system, an analog/digital photon counting detector, selected from only our best quality and performing photo-multipliers, the 814 series. You may also select one of the excellent Red sensitive PMT's to complement the system.

Analog/Digital Photon Counting

Model 814 is a compact PMT housing for analog or digital (photon-counting) detection. The detection mode is switchable, and the built-in LCD can also selectively display high voltage or analog signal level. Features power on/off switch, high voltage adjust, LCD high voltage/analog signal display, detection mode and display mode switches, gain, time constant and offset adjustment controls, BNC signal output connection, BNC external high voltage adjust input connection, light-tight RF shielded case, internal direct anode output mode control, and socket for most 1-1/8 inch side-on photomultiplier tubes. Includes a separate wall-mount line voltage power supply. This detection system excels at applications like the following:

  • Live-cell imaging

  • High-speed emission ratio imaging

  • Quantitative FRET, FRAP, FISH

  • Luminescence

Analog Mode:

This mode can be used for medium to high levels of light intensity. The maximum PMT current is 10 microamperes. The output is a DC signal between +13 Volts and -13 Volts.

Photon-Counting (Digital) Mode:

This mode can be used for low to medium light levels up to 4 million counts per second. The output is a TTL level, active low signal. The signal line must be terminated at 50 ohms. The output is a frequency corresponding to the number of photons impinging on the photocathode.

Digital Photometer Specifications

Maximum count rate4 MHz
Pulse pair resolution250 ns
OutputTTL level active low pulse
Rise time20 ns
Fall time100 ns
Pulse width220 ns

Model 814 PMT Housing

Model 814 is a compact PMT housing for analog or digital (photon-counting) detection. The detection mode is switchable, and the built-in LCD can also selectively display high voltage or analog signal level.

Features power on/off switch, high voltage adjust, LCD high voltage/analog signal display, detection mode and display mode switches, gain, time constant and offset adjustment controls, BNC signal output connection, BNC external high voltage adjust input connection, light-tight RF shielded case, internal direct anode output mode control, and socket for most 1–1/8 inch side-on photomultiplier tubes. Includes a separate wall-mount line voltage power supply.

Analog Mode:

This mode can be used for medium to high levels of light intensity. The maximum PMT current is 10 microamperes. The output is a DC signal between +13 Volts and -13 Volts. This signal is usually measured with a voltmeter, a recorder, or the analog-to-digital converter in a general-purpose I/O board in a computer.

Photon-Counting (Digital) Mode: 

This mode can be used for low to medium light levels up to 4 million counts per second. The output is a TTL level, active low signal. The signal line must be terminated at 50 ohms. The output is a frequency corresponding to the number of photons impinging upon the photocathode, and is usually measured with a counter in a general-purpose I/O board in a computer.

Direct PMT Output Mode: 

This mode applies the signal from the photomultiplier anode directly to the output BNC. This is generally used only when the highest-speed response is desired. Internal digital or analog signal processing is completely bypassed. The peripheral equipment connected to the housing must be properly configured to accept the signal directly from the PMT itself.

High Voltage Power Supply Specifications

Input+/- 15 VDC, 250 mA
High voltage-200 to -1,100 VDC manually adjustable (LCD display indicates actual cathode voltage)
External high voltage adjust0 to +5 VDC (0 = -200 V, 5 = -1,100 V), continuously adjustable
Input regulation+/- 0.05% max. (for 15 V +/-1 V input)
Load regulation+/- 0.05% max.
Ripple100 mV p-p max.
Temperature coefficient+/- 0.01% max. (+5 to +40° C)
Drift+/- 0.03%/hr max. (after 15 minute warm-up)

PMT

Your choice of 2 PMTs

R 1527
Spectral Response185 to 680 nm
Photocathode MaterialLow noise bialkali
Effective Area of PMT8 x 24 mm
Supply Voltage1250 V dc

Cathode Sensitivity

Quantum Efficiency at 300 nm (Peak)

Luminous

Radiant 400 nm (Peak)

19 % typ.

60 µA/lm typ.

60 mA/W typ.

Anode Sensitivity

Luminous

Radiant 400 nm

400 A/lm typ.

4 x 105 A/W typ.

Gain6.7 x 106 typ.
Anode Dark Current 
(After 30minute Storage in the darkness)
0.1 nA

R 928
Spectral Response185 to 900 nm
Photocathode MaterialMultialkali
Effective Area of PMT8 x 24 mm
Supply Voltage1250 V dc

Cathode Sensitivity

Quantum Efficiency at 260 nm (Peak)

Luminous

Radiant 400 nm

25.4 % typ.

250 µA/lm typ.

74 mA/W typ.

Anode Sensitivity

Luminous

Radiant 400 nm

2500 A/lm typ.

7.4 x 105 A/W typ.

Gain1 x 107 typ.
Anode Dark Current 
(After 30minute Storage in the darkness)
3 nA

Analog PMT Specifications

Gain settings1, 0.1, 0.01, 0.001 µA = 1 V
Time constant settings0.05, 0.5, 5, 50 and 500 msec
Offset correction+/-50 nA
Inherent noise50 pA p-p typical, with 0.05 msec time constant
Dimensions (h x w x d)7.39 x 4.04 x 4.02 inches

Digital PMT Specifications

Maximum count rate4 MHz
Pulse pair resolution250 ns
OutputTTL level active low pulse
Rise time20 ns
Fall time100 ns
Pulse width220 ns
Dimensions (h x w x d)7.39 x 4.04 x 4.02 inches




厂家资料

地址:上海市天山西路1068号联强国际广场A栋1层D单元

电话:400-6699-117 转 6216

经销商

售后服务

我会维修/培训/做方法

如果您是一名工程师或者专业维修科学 仪器的服务商,都可参与登记,我们的平台 会为您的服务精确的定位并展示。

1该产品的品牌知名度如何?
2你对该产品的使用感受如何?
3该产品的性价比如何?
4该产品的售务如何?
查看
在线咨询

在线咨询时间:

周一至周五

早9:00 - 晚17:30

若您在周六周日咨询,请直接留言您所咨询的产品名称+联系人+电话