SPECIFICATIONS:
PINNACLE PCX SPECIFICATIONS
Dimensions: (h x w x d): 54 x 26.7 x 46.4 cm
(21.25 x 10.5 x 18.25 inches)
Weight: 54.4 lbs (24.7 Kg) – Duplex
Electrical: 100-120 V, 50/60 Hz, 1.7 A, 200 W or 200-240 V, 50/60 Hz, 0.8 A, 200 W
Mains voltage ± 10 % of nominal
Installation (over voltage) category II, pollution degree 2
Indoor use only
Environmental: Altitude up to 6500 ft
Ambient Temperature 15 °- 25 °C
Relative humidity up to 80 % at 31 °C
REAGENT PUMPS
True pulse-free syringe pump
Single piece ceramic barrel
Completely inert flow path
Maximum operating pressure 500 psi
Programmable flow rate
Flow range: 50 μL to 1500 μL/minute
Flow Accuracy 3 %
Flow Precision 0.5 % RSD
Refill cycle of 60 seconds
Automatic piston wash
Automatic reagent flush cycle
No check valves
CONTROL
Computer controlled
Windows PC with XP, Vista or Windows 7
USB connection or network
REACTOR
Heated reactor for temperature from 5 °C above ambient to 130 °C
Easy replacement reactor coil cartridges
Range of reactor dwell volumes; 0.1 mL to 3.5 mL
Reaction coil withstands up to 42 bar (600 psi) inlet pressure at 130 °C
Thermal safety switch limits temperature to 150 °C to prevent damage
Fast response
SAFEGUARDS
In-line check valve: Prevents reagent back flow into the column when HPLC pressure drops
Post-column system over pressure: A pre-calibrated relief valve opens at 35 bar (500 psi) to prevent rupture of the post-column reactor tubing in the event of down-stream blockage
Back-pressure regulator: Applies 7 bar (100 psi) to the detector flow cell outlet (waste) to prevent detector noise and precipitation due to out-gassing or boiling
COLUMN HEATER AND REACTOR CONTROLLER
Heater accepts up to 6 or 8 mm OD (0.25 or 0.31 inch) x 50-250 mm in length (column and guard)
Programmable temperature gradient
Power cooling capability
Temperature holds within ± 0.4 °C from the set point. Can be set with 1 °C resolution from 5 °C above ambient to 75 °C
Easy column access
INSTRUMENT PACKAGE AND FLOW PATH
Advanced fluidics valve management system
Easy access to internal components
Standard fittings
Post-column pressure relief valve
Side panels easily removed for service access
Integrated reagent reservoir tray
Corrosion proof pan and panels
DISPLAY
Backlit LCD
Real time temperature and pressure display
System status icons
Simple system control interface
GAS PRESSURE MANIFOLD AND REGULATOR
Panel mount manifold
Regulator maintains 0.3 bar (3-5 psi) on reagent reservoirs with 3-5 bar (45-75 psi) source pressure
Safety pressure relief valve opens at 1 bar (14 psi)
Manifold has two 1/4-28 tubing connections
Gas lines with anti-syphon valves
PRESSURIZED REAGENT RESERVOIR
One liter capacity (2 L reservoirs available)
Maintained under inert gas pressure to inhibit oxidation of oxygen-sensitive reagents
Valve built into reservoir cap permits sparging during reagent preparation
Reagent reservoirs fitted with 3.1 mm (1/8”) OD, oxygen-impermeable Air Barrier tubing for oxygen-sensitive reagents
售后服务
我会维修/培训/做方法
如果您是一名工程师或者专业维修科学 仪器的服务商,都可参与登记,我们的平台 会为您的服务精确的定位并展示。