UVE专用紫外衍射生化仪,它主要用于黄曲霉素的检测方法(GB/T18979-2003和GB/T18980-2004),其样品分离净化步骤采用“免疫亲和柱法”,后接高效液相色谱/柱后衍生技术/FLD相结合进行检测,方法简单、测定范围广泛(0-300ppb)等多项优点。
产品特点
1、专用于黄曲霉毒素检测的柱后衍生。
2、没有衍生化试剂消耗(通常柱后衍生均需要使用衍生化试剂,分析成本高,操作麻烦) 。
3、衍生化反应充分,方便,快捷。
Photochemical Reactor for the Derivatisation of Aflatoxins with UV-Light
Due to the low aflatoxins limits in food and low inherent fluorescence of aflatoxins B1 and G1, aflatoxin analysis needs to be optimised through derivatisation.
This is done photochemically with the UVE under UV light radiation at 254 nm.
Aflatoxins B1 and G1 are thereby hydroxilated and can then be measured through fluorescence spectrometry. The sensitivity of the measurement increases considerably.
Key advantage of using UVE over electrochemical bromination: the water, present in the eluent, is used as the reagent, hence neither iodine nor HNO3 / KBr are required. In addition, the detector will not be contaminated and no variation in derivatisation will occur. This method is accepted by the AOAC, has been used successfully in collaborative trials and is in use worldwide in accredited laboratories.
In Short, LCTech UVE
The UV lamp is designed for an operation of over several thousand hours.
No toxic reagents are necessary, because water is used as reagent.
Increase of fluorescence of Aflatoxin B1 and G1 by UV light.
Comparable to Cobra cell, but no reagents needed.
Can be used with any HPLC.
The HPLC system stays clean and is immediately ready for other applications; no more complex rinsing required.
Easy Plug and Play installation: connect UVE with HPLC and detector, then turn on; the unit is ready for operation. Compact device: 15 cm wide, 9 cm high, 27 cm deep
Low costs and maintenance
European CE certificate and DIN ISO certified
Easy and Effective
The UVE derivatization module allows easily analysing aflatoxins with HPLC. The reaction is a simple derivatization of B1 to B2a.
The application can be done easily. Simply place the UVE between the HPLC and the fluorescence detector, switch on the system – ready:
Up to now reagents had to be added for the derivatization – whereas the photochemical reactor directly uses the HPLC eluent as reagent. The HPLC system remains clean and can immediately be used for other methods. Any tedious and long lasting rinsing of the system is no longer necessary.
A confirmation analysis of the aflatoxins B1 and G1 can be performed by switching off the system without any displacement of the retention times.
The system is very robust and long-living.
References
Muscarella, M. et al., Food Additives and Contaminants, Vol. 26, No. 10, October 2009, 1402-1410, Validation of a confirmatory analytical method for the determination of aflatoxins B1, B2, G1 and G2 in foods and feed materials by HPLC with on-line photochemical derivatization and fluorescence detection
Papadopoulou-Bouraoui A., Stroka J., Anklam E., J., AOAC Int. Vol. 85, No. 2, 2002, 411-416, Comparison of two post-column derivatization systems, ultraviolet irradiation and electrochemical determination, for the liquid chromatographic determination of aflatoxins in food
FAPAS Proficiency Test 04148 Report, Aflatoxins B & G in Maize, October - November 2009
FAPAS Proficiency Test 04143 Report, Aflatoxins Analysis in Baby Food, July - August 2009
Barricelli M, Kupfer R, Börner B, Deutsche Lebensmittel-Rundschau Spezial, Validated Method for Simultaneous Determination of Aflatoxins and Ochratoxin A in Paprika and Chilli Powder, September 2010
除厂家/中国总经销商外,我们找不到
LC-Tech UVE衍生化仪 的一般经销商信息,有可能该产品在中国没有其它经销商。
如果您是,请告诉我们,我们的邮件地址是:sales@antpedia.net 请说明: 1.产品名称 2.公司介绍 3.联系方式 |
售后服务
我会维修/培训/做方法
如果您是一名工程师或者专业维修科学 仪器的服务商,都可参与登记,我们的平台 会为您的服务精确的定位并展示。