3730 基因分析仪技术参数:
Number of Capillaries: | 48 Capillaries |
Capacity: | 16 sample plates (96-well or 384-well) |
Throughput: | StdSeq: 1152 samples/day (775 Kbases), FastSeq: 1152 samples/day (800 Kbases), LongSeq: 576 samples/day (490 Kbases), RapidSeq: 1920 samples/day (1050 Kbases), GeneMapper® Software: 2112 samples/day (46,000 genotypes), XLRseq: 384 samples/day (345 Kbases) |
Performance: | FastSeq: 50cm - 700 QV20 base/60 min, GeneMapper® Software: 36cm - up to 500 bp res w/ 0.15 bp precision in 34 min, RapidSeq: 36cm - 550 QV20 bases/36 min, XLRseq: 50cm - 900 QV20 base/360 min, LongSeq: 50cm - 850 QV20 base/120 min, StdSeq: 36cm - 700 QV20 base/60 min |
Read Length: | 400 - 900 bases (varies depending on run module) |
Capillary Length: | 36 cm or 50 cm |
Compatible Polymers: | POP Conformational Analysis Polymer, POP-7 |
Polymer Consumption: | 36 cm: 100µl⁄run, 50 cm: 125µl⁄run |
Platform: | 3730 DNA Analyzer |
Format: | 384-well plate, 96-well plate |
Dimensions: | 100 cm (W) x 73 cm (D) x 89 cm (H) |
Weight: | 180 kg (computer - 30 kg) |
Product Size: | 1 system |
Plate Handling: | Internal bar code reader, Plate Seal: Automatic on-board piercing (septa or polypropylene heat seal), Integrated auto sampler and plate stacker |
Sample Volume: | 5-30 µl for 384-well plate, 10-50 µl for 96-well plate |
External Computer: | Computer and Flat Panel Monitor |
Operating System: | Windows 2000, Windows XP |
Memory: | 1 GB 400MHz RAM |
Optics: | Backside-thinned CCD for maximum optical sensitivity, In-capillary detection by dual-side illumination, Multiple Filter Sets: Z, E, G5, G5-RCT, Any4Dyeset, Any5Dyeset and S (optional) |
Frequency: | 50⁄60 Hz |
Plan Duration: | 1 Year Limited Warranty on Parts and Labor |
System Upgrade: | Upgradeable to 96 capillaries (3730xl) |
Reagent Handling: | Simultaneous injection of 48 samples, On-board reagents for up to 48 hrs unattended operation (with certain run modules), Automated polymer replenishment pump for increased throughput |
Temperature Range: | Temperature-controlled oven (18-70°C range) and detection cell heater |
Power Requirements: | Power Dissipated: About 2000 watts, Current: 15 amps max. Requires 30 amp receptacle w/in 3 m (10 ft) of instrument back., Voltage: 200-220 V or 230-240 V ±10% |
Regulatory Statement: | For Research Use Only. Not for use in diagnostic procedures. |
Operating Environment: | Humidity: 20%-80% (non-condensing), Temperature: 18°C-30°C |
High Throughput Compatibility: | High Throughput-Compatible |
3730 xl 基因分析仪技术参数
Number of Capillaries: | 96 Capillaries |
Capacity: | 16 sample plates (96-well or 384-well) |
Throughput: | GeneMapper® Software: 4224 samples per day (92,000 genotypes), FastSeq: 2304 samples/day (1600 Kbases), RapidSeq: 3840 samples per day (2100 Kbases), XLRseq: 768 samples per day (690 Kbases), LongSeq: 1152 samples/day (980 Kbases), StdSeq: 2304 samples/day (1550 Kbases) |
Performance: | GeneMapper® Software: 36cm - up to 500 bp res. w/ 0.15 bp sizing precision in 34 min, FastSeq: 50cm - 700 QV20 bases/1 hour, RapidSeq: 36cm - 550 QV20 bases/36 min, XLRseq: 50cm - 900 QV20 bases/3 hours, LongSeq: 50cm - 850 QV20 bases/2 hours, StdSeq: 36cm - 700 QV20 bases/1 hour |
Read Length: | 400 - 900 bases (varies depending on run module) |
Capillary Length: | 36 cm or 50 cm |
Compatible Polymers: | POP-7, POP Conformational Analysis Polymer |
Polymer Consumption: | 36 cm: 200µl⁄run, 50 cm: 250µl⁄run |
Platform: | 3730xl DNA Analyzer |
Format: | 384-well plate, 96-well plate |
Dimensions: | 100 cm (W) x 73 cm (D) x 89 cm (H) |
Weight: | 180 kg (computer - 30 kg) |
Product Size: | 1 system |
Plate Handling: | Internal bar code reader, Plate Seal: Automatic on-board piercing (septa or polypropylene heat seal), Integrated auto sampler and plate stacker |
Sample Volume: | 5-30 µl for 384-well plate, 10-50 µl for 96-well plate |
External Computer: | Computer and Flat Panel Monitor |
Operating System: | Windows 2000, Windows XP |
Memory: | 1 GB 400MHz RAM |
Optics: | Backside-thinned CCD for maximum optical sensitivity, Multiple Filter Sets: Z, E, G5, G5-RCT, Any4Dyeset, Any5Dyeset and S (optional), In-capillary detection by dual-side illumination |
Plan Duration: | 1 Year Limited Warranty on Parts and Labor |
Reagent Handling: | Automated polymer replenishment pump for increased throughput, On-board reagents for up to 48 hrs unattended operation (with certain run modules), Run modules: 5 sequencing, 1 fragment analysis and optional SNPlex™ |
Temperature Range: | Temperature-controlled oven (18-70°C range) and detection cell heater |
Power Requirements: | Power Dissipated: About 2000 watts, Current: 15 amps max. Requires 30 amp receptacle w/in 3 m (10 ft) of instrument back., Voltage: 200-220 V or 230-240 V ±10% |
Regulatory Statement: | For Research Use Only. Not for use in diagnostic procedures. |
Operating Environment: | Humidity: 20%-80% (non-condensing), Temperature: 18°C-30°C |
High Throughput Compatibility: | High Throughput-Compatible |
规格指标:
激光:氩离子激光光源,激发波长为488nm和514.5nm
电泳电压:高达20kV
运行温度:18℃到70℃
计算机要求
硬件: PentiumⅣ处理器
操作系统:Windows ®2000
内存: 1GB
硬盘: 72GB硬盘
显示器:17寸彩色显示器
运行环境
室温:18-30℃
湿度:20%-80%
主电源
电压:200-220伏或230-240伏+/-10% 50/60HZ +/-10%|
电流:zei大15安培
zei大电源功率:2000瓦
仪器尺寸
宽度:100cm
深度:73cm
高度:89cm
重量:180kg
请扫描二维码查看详细参数
经销商
除厂家/中国总经销商外,我们找不到 3730 & 3730xl DNA 基因分析仪/测序仪 的一般经销商信息,有可能该产品在中国没有其它经销商。
如果您是,请告诉我们,我们的邮件地址是:sales@antpedia.net 请说明: 1.产品名称 2.公司介绍 3.联系方式 |
基因/DNA测序仪
售后服务
我会维修/培训/做方法
如果您是一名工程师或者专业维修科学 仪器的服务商,都可参与登记,我们的平台 会为您的服务精确的定位并展示。