Features | Specifications |
Altitude | Up to 2000 m (6500 ft) |
Elution volume | QIAsymphony SP — 30–500 µl (application dependent) |
Features | Rotor-Gene Q — dynamic range, 10 orders of magnitude |
Heat dissipation/thermal load | Rotor-Gene Q — average, 0.183 kW (632 BTU/hour); peak, 0.458 kW (1578 BTU/hour) |
Humidity | QIAsymphony SP/AS — relative humidity of 15–75% (noncondensing); maximum 75% relative humidity for temperatures up to 31°C, decreasing linearly to 50% humidity at 32°C Rotor-Gene Q — relative humidity of 10–75% (noncondensing) |
Input volume | QIAsymphony SP — minimum input volume: 200 µl (application dependent) |
Instrument dimensions | QIAsymphony SP/AS — QIAsymphony SP, 128 x 103 x 73 cm; QIAsymphony AS, 59 x 103 x 73 cm; QIAsymphony SP/AS (integrated operation), 185 x 103 x 73 cm Rotor-Gene Q — width, 37 cm (14.6 in.); height, 28.6 cm (11.3 in.); depth (without cables), 42 cm (16.5 in.); depth (door open), 53.8 cm (21.2 in.) |
Kits or Application Packs designed for this instrument | QIAsymphony SP — QIAsymphony DSP Virus/Pathogen Kits and other QIAsymphony Kits; QIAsymphony AS — artus QS-RGQ Kits (not available in all countries), Rotor-Gene Kits and other QIAGEN real-time and end-point PCR kits Rotor-Gene Q — artus QS-RGQ Kits (not available in all countries), RG SYBR Green PCR Kits; RG SYBR Green RT-PCR Kit; RG Probe PCR Kits; RG Probe RT-PCR Kit; RG Multiplex PCR Kit |
Operating temperature | QIAsymphony SP/AS — 15–32°C (59–89.6ºF) Rotor-Gene Q — 18–30ºC (64–86ºF) |
Optical System | Rotor-Gene Q — up to 6 channels spanning UV to infra-red wavelengths; excitation sources: high energy light-emitting diodes; detector: photomultiplier; acquisition time: 4 s; the software allows to create new excitation/detection wavelength combinations |
Overvoltage category | II |
Place of operation | For indoor use only |
Pollution level | QIAsymphony SP/AS — 2 Rotor-Gene Q — 2; Environmental class 3K2 (IEC 60721-3-3) |
Power | QIAsymphony SP/AS — 100–240 V AC, 50–60 Hz, 1400 VA, mains supply voltage are not to exceed 10% of nominal supply voltages Rotor-Gene Q — 100–240 V AC, 50–60 Hz, 520 VA (peak); Power consumption 8 VA (standby); Mains supply voltage fluctuations are not to exceed 10% of the nominal supply voltages; F5A 250 V fuse |
Processing | QIAsymphony SP/AS — automated |
Protocols/main application on this instrument | QIAsymphony SP — purification of DNA, RNA, and bacterial and viral nucleic acids from a wide range of starting materials QIAsymphony AS — PCR setup Rotor-Gene Q — gene expression analysis, microRNA detection, virus detection, SNP genotyping, SNP genotyping, High Resolution Melt analysis (HRM) |
Samples per run (throughput) | QIAsymphony SP — 1–96 samples in batches of 24 Rotor-Gene Q — tubes 0.2 ml; strip tubes 0.1 ml (4 tubes); Rotor-Disc 72; Rotor-Disc 100; up to 100 samples per run using a Rotor-Disc 100 |
Software | Rotor-Gene Q — Rotor-Gene Q software, supplied on the provided installation CD |
Storage temperature | QIAsymphony SP/AS — 5–40°C (41ºF to 104ºF) in manufacturer's package Rotor-Gene Q — 15 to 30ºC (59ºF to 86ºF) in manufacturer’s package; max. 75% relative humidity (noncondensing); environmental class 1K2 (IEC 60721-3-1) |
Technology | QIAsymphony SP — QIAGEN magnetic-particles chemistry Rotor-Gene Q — real-time PCR cycler |
Thermal performance | Rotor-Gene Q — temperature range, 35 to 99ºC; temperature accuracy, ±0.5ºC (type, measured 30 seconds after clock start); temperature resolution, ±0.02ºC (smallest programmable increment); temperature uniformity, ±0.02ºC; ramp rate (peak ramp rates, air), >15ºC/s heating, >20ºC/s cooling |
Transportation conditions | QIAsymphony SP/AS — –25 to 70°C (–13ºF to 158ºF) in manufacturer's package Rotor-Gene Q — –25 to 60ºC (–13ºF to 140ºF) in manufacturer’s package; max. 75% relative humidity (noncondensing); environmental class 2K2 (IEC 60721-3-2) |
Typical run time | Rotor-Gene Q — 40 cycles in 45 min with the QIAGEN RG Kits (assay dependent) |
Warranty | Rotor-Gene Q — 1 year on instrument; lifetime guarantee on excitation LEDs |
Weight | QIAsymphony SP, 175 kg; QIAsymphony AS, 90 kg; QIAsymphony SP/AS (integrated operation), 265 kg; Rotor-Gene Q, 12.5 kg (27.6 lb.) (standard configuration) |
请扫描二维码查看详细参数
经销商
除厂家/中国总经销商外,我们找不到 QIAsymphony RGQ核酸提取纯化分析仪 的一般经销商信息,有可能该产品在中国没有其它经销商。
如果您是,请告诉我们,我们的邮件地址是:sales@antpedia.net 请说明: 1.产品名称 2.公司介绍 3.联系方式 |
核酸纯化系统/核酸提取仪
售后服务
我会维修/培训/做方法
如果您是一名工程师或者专业维修科学 仪器的服务商,都可参与登记,我们的平台 会为您的服务精确的定位并展示。