产品规格 | - |
---|---|
准确度(光度) | 1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters traceable to NIST |
基线平坦度 | ±0.0010A, 200-800nm, 1.0nm SBW, smoothing |
射束几何形状 | Double-beam with Application Focused Beam Geometry |
认证/合规 | ISO 9001:2008 |
Data Interval | 10, 5, 2, 1.0, 0.5, 0.2, 0.1nm |
描述 | Evolution 260 Bio Spectrophotometer plus Tablet Control Module - International |
检测器类型 | Dual Silicon Photodiodes |
Dimensions (L x W x H) | 62.2 x 48.6 x 27.9 cm |
显示 | Touchscreen LCD panel; 800 x 480; 17.8 cm (7 in. diagonal) |
漂移 | <0.0005 A/hr, 500 nm, 1.0nm SBW, 1 hr warm-up |
Electrical Requirements | 100-240 V 50-60 Hz selected automatically150W maximum |
物品描述 | Evolution 260 Bio Spectrophotometer plus Tablet Control Module - International |
键盘 | Sealed membrane |
灯 | Xenon Flash Lamp, 3-year warranty (7 years typical lifetime) |
噪声 | 0A: <0.00015A 1A: <0.00025A 2A: <0.00080A 260nm, 1.0nm SBW, RMS |
操作系统 | Microsoft Windows™ XP embedded INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument |
光学设计 | Double Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator |
Pharmacopoeia Compliance Testing | (Guaranteed Performance Specifications) Resolution (toluene in Hexane): ≥1.8A Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line |
Photometric Accuracy Instrument | 1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters traceable to NIST |
Photometric Display | -0.3 - 4.0A |
Photometric Range | >3.5A |
Photometric Repeatability | ±0.0002A |
Scan Ordinate Modes | Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity |
扫描速度. | <1-6000nm/min, variable |
光谱带宽 | Variable: 1.0nm; 2.0nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized |
类型 | Evolution 260 Bio Spectrophotometer plus Tablet Control Module - International |
波长精度 | ±0.5nm (541.9, 546.1nm mercury lines) ±0.8nm (full range 190-1100nm) |
波长范围 | 190 - 1,100nm |
波长扫描速度 | <1 to 6,000 nm/min; variable |
重量(公制) | 14.4 kg |
Evolution 260 Bio本地控制光谱
准确度(光度) | 1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters traceable to NIST |
基线平坦度 | ± 0.0010A , 200-800纳米, 1.0纳米SBW ,平滑 |
射束几何形状 | Double-beam with Application Focused Beam Geometry |
认证/合规 | ISO 9001:2008 |
连接 | USB或RS- 232 |
Data Interval | 10, 5, 2, 1.0, 0.5, 0.2, 0.1nm |
深度(英制) | 10英寸 |
深度(公制) | 48.6 cm |
描述 | Evolution 260 Bio Local Control Spectrophotometer |
检测器类型 | Dual Silicon Photodiodes |
Dimensions (L x W x H) | 62.2 x 48.6 x 27.9 cm |
显示 | 7英寸(17.8 cm)液晶屏 |
漂移 | < 0.0005 /小时, 500纳米, SBW为1.0nm , 1小时热身 |
Electrical Requirements | 100-240 V 50-60 Hz selected automatically 150W maximum |
高度(英制) | 11英寸 |
高度(公制) | 27.9 cm |
赫兹 | 50-60 Hz |
物品描述 | 进化260 LC分光光度计 |
键盘 | Sealed membrane |
灯 | 氙气闪光灯 |
zei小数据间隔 | 1 nm |
噪声 | 0A: <0.00015A 1A: <0.00025A 2A: <0.00080A 260nm, 1.0nm SBW, RMS |
操作系统 | Microsoft Windows™ XP embedded INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument |
光学设计 | Double Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator |
路径长度(公制) | 可达100 mm比色皿 |
Pharmacopoeia Compliance Testing | (Guaranteed Performance Specifications) Resolution (toluene in Hexane): ≥1.8A Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line |
Photometric Accuracy Instrument | 1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters traceable to NIST |
Photometric Display | -0.3 - 4.0A |
Photometric Range | >3.5A |
Photometric Repeatability | ±0.0002A |
范围(光度) | > 3.5A |
分离度(甲苯/己烷) | > 1.6 (峰 - 谷比) |
Scan Ordinate Modes | Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity |
扫描速度 | 1-6000nm/min ,变 |
光谱带宽 | Variable: 1.0nm; 2.0nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized |
杂散光 | - |
类型 | Evolution 260 Bio Local Control Spectrophotometer |
电压 | 100-240 V |
瓦数 | 150 Wzei大 |
波长精度 | ± 0.8 nm |
波长范围 | 190 - 1100纳米 |
波长扫描速度 | <1到6000纳米/分钟;变量 |
波长回转速度 | 31,000纳米/分钟 |
重量(英制) | 32镑 |
重量(公制) | 14.4 kg |
宽度(英制) | 19英寸 |
宽度(公制) | 48.6 cm |
Warranty | 3年保修氙气灯 |
Evolution 260 Bio 计算机控制光谱 参数
准确度(光度) | 1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters traceable to NIST |
基线平坦度 | ± 0.0010A , 200 - 800nm的, SBW为1.0nm ,平滑 |
射束几何形状 | Double-beam with Application Focused Beam Geometry |
认证/合规 | ISO 9001:2008 |
连接 | USB或RS- 232 |
Data Interval | 10, 5, 2, 1.0, 0.5, 0.2, 0.1nm |
深度(英制) | 10英寸 |
深度(公制) | 48.6 cm |
描述 | Evolution 260 Bio Computer Control Spectrophotometer |
检测器类型 | Dual Silicon Photodiodes |
Dimensions (L x W x H) | 62.2 x 48.6 x 27.9 cm |
显示 | Touchscreen LCD panel; 800 x 480; 17.8 cm (7 in. diagonal) |
漂移 | < 0.0005A/hr , 500nm处, SBW为1.0nm , 1小时热身 |
Electrical Requirements | 100-240 V 50-60 Hz selected automatically 150W maximum |
高度(英制) | 11英寸 |
高度(公制) | 27.9 cm |
赫兹 | 50-60 Hz |
物品描述 | 进化260电脑分光光度计 |
键盘 | Sealed membrane |
灯 | 氙气闪光灯 |
zei小数据间隔 | 为1nm |
噪声 | 0A: <0.00015A 1A: <0.00025A 2A: <0.00080A 260nm, 1.0nm SBW, RMS |
操作系统 | Microsoft Windows™ XP embedded INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument |
光学设计 | Double Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator |
路径长度(公制) | 可达100 mm比色皿 |
Pharmacopoeia Compliance Testing | (Guaranteed Performance Specifications) Resolution (toluene in Hexane): ≥1.8A Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line |
Photometric Accuracy Instrument | 1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters traceable to NIST |
Photometric Display | -0.3 - 4.0A |
Photometric Range | >3.5A |
Photometric Repeatability | ±0.0002A |
范围(光度) | > 3.5A |
分离度(甲苯/己烷) | > 1.6 (峰 - 谷比) |
Scan Ordinate Modes | Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity |
扫描速度 | 1-6000nm/min ,变 |
光谱带宽 | Variable: 1.0nm; 2.0nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized |
杂散光 | - |
类型 | Evolution 260 Bio Computer Control Spectrophotometer |
电压 | 100 -240 V |
瓦数 | 150Wzei大 |
波长精度 | ± 0.8nm的 |
波长范围 | 190到1100nm的 |
波长扫描速度 | < 1 6000nm/min ;变量 |
波长回转速度 | 31,000纳米/分钟 |
重量(英制) | 32镑 |
重量(公制) | 14.4 kg |
宽度(英制) | 19英寸 |
宽度(公制) | 48.6 cm |
Warranty | 3年灯泡保修氙气灯 |