产品参数
波长范围:190nm-900nm(自动设定)
波长准确度:±0.15nm
波长重复性:≤0.10nm
狭缝:0.1,0.2.0.7,1.4nm四档(自动换档)
单色器类型:C-T型单色器
焦距:350nm;
光栅:1200条/nm;
闪烁波长:250nm;
稳定性:Cu324.7nm≤0.004Abs/30min
分辨力:<30%(Mn双线,波谷)
检出极限:CuO.007ug/ml
外光路:全反射单光路镜片涂有保护膜
D2灯背景扣除:背景校正能力>30倍
四灯转塔,同时点二灯(自动点灯换灯及寻峰
火焰类型:空气/乙炔,笑气/乙炔
数据处理模式灵活:连续读数,积分平均,标尺变换,斜率重置,标准加入法,显示工作曲线及测定曲线。同时测峰高峰面积(可事后重现、重组、重算,寻找最佳方案),浓度直读,多种线性、非线性回归曲线,多达8点的标样校正。工作曲线可反复使用
特别申明:⑴本网站所列价目,如厂方有变动,请以厂家新价格为准。
⑵批发优惠幅度因各厂情况不同,请来电咨询。
Analytical Instruments Co., Ltd. Shanghai Jinpeng excellent chemical and biological laboratory equipment and foreign manufacturing experience exclusively produced AA370MC atomic absorption spectrophotometer, systematic Xiangjie to quickly check the latest products, quotes, pictures, technical parameters, or product performance comparison, very convenient to use.
AA370MC-type atomic absorption spectrophotometer ● Fully automatic: automatically adjusted according to the selected element of the factory's recommended conditions of work or transferred out according to the last measurement, and allows you to modify the original conditions of (), to confirm, press Enter, then the high-pressure, light current and slit, the wavelength and lamp position (including the lighthouse rotation) and precise optical adjustment step in place, no longer need to manually fine-tuning
● be able to Memory: boot can remember working conditions for each measurement, the working curve and more than 2000 measured data so that the next call or print (not a battery)
● Quick start in place: after booting the state is confirmed, that is able to quickly access the best position, not of a long time for calibration
● The most streamlined operation of gas control design: ignition / flame with a key, the flame type switch with a key (any occasion available), only one knob to adjust the ignition after the acetylene flow rate. (Such as the conditions remain unchanged, the next time the ignition is not required to re-adjust)
● the most secure: all gases have flow meters for visual monitoring, timely detection of a variety of reasons can be caused by gas breakdown. Special safety devices to ensure a fail-safe switching of the gas. And have power outages, breathe, undervoltage, burning head judge, tempering protection (and with a light control) and other safety measures, can be automatically cut off the gas supply. Modular design of the gas line, small size and good reliability
● new combustion head: rapid thermal balance, long life, the whole cast titanium with a heat sink
● advanced optical system: non-glare color single-beam optical system. Automatically eliminate wavelength errors
● a new type of display devices: ultra-thin large screen LCD backlight characters Mu round display, menu-style operation, showing the working curve and determination of real-time curves, the different functions of different executable images (including maintenance)
● Tip-type determination of operation: to avoid misoperation beginners
● High Accuracy: wavelength accuracy of ± 0.15nm, wavelength repeatability is less than 0.10nm
● Multi-function: atomic absorption, flame emission, Hydride / on-line enrichment, graphite furnace, D2 lamp background deduction. Inspection and maintenance of factory index with diagnostic functions (full-time maintenance engineer and the factory-specific) and Paperless Recorder features
● a variety of print specifications: the same element in different samples or the same sample determination of different elements in the report, Chinese / English selectable. And a screen copy function
There RS232C interfaces with external computer communication; peripherals: Imported ink-jet printers, graphite furnace and hydride / on-line enrichment flow injection analyzer; sets of: host, printers, air compressor, copper, gas bottle valve, and all external pipes, tools, etc.
Usage
In biological research or bio-industrial experiments
Product parameter
Wavelength range: 190nm-900nm (automatically set)
Wavelength Accuracy: ± 0.15nm
Wavelength repeatability: ≤ 0.10nm
Slit: 0.1,0.2.0.7,1.4 nm fourth gear (automatic transmission)
Monochromator Type: C-T-type monochromator
Focal length: 350nm;
Grating: 1200 / nm;
Scintillation wavelength: 250nm;
Stability: Cu324.7nm ≤ 0.004Abs/30min
Resolution: <30% (Mn wire, trough)
Detection limit: CuO.007ug/ml
Outside the light path: ATR single optical lens coated with protective film
D2 lamp background deduction: background correction capability “30 times
4 lamp turret at the same time points, 2 light (automatic lighting for lights and look for peaks
Flame Type: Air / acetylene, nitrous oxide / acetylene
A flexible data processing mode: continuous readings, integral average, gauge transformation, the slope of reset, the standard addition method, display working curve and the determination of curves. At the same time measuring the peak area of peak (which can subsequently reproduce, restructuring, re-calculation to find the best option), the concentration of direct-reading, multi-linear, non-linear regression curve, up to 8 of the standard sample calibration. Working curve can be used repeatedly
In particular that: ⑴ prices listed on this site, such as a change in the factory, please factory new price shall prevail.