IEC 62387-1:2007
辐射防护测量仪.环境和个人监测用无源集成放射量测定系统.第1部分:一般特性和性能要求

Radiation protection instrumentation - Passive integrating dosimetry systems for environmental and personal monitoring - Part 1: General characteristics and performance requirements


标准号
IEC 62387-1:2007
发布
2007年
发布单位
国际电工委员会
当前最新
IEC 62387-1:2007
 
 
代替标准
IEC 62387:2012
适用范围
This part of IEC 62387 applies to all kinds of passive dosimetry systems that are used for measuring the personal dose equivalents Hp(10) or Hp(0,07) or the ambient dose equivalent H*(10). It applies to dosimetry systems that measure external photon or beta radiation in the dose range between 0,01 mSv and 10 Sv and in the energy ranges given in the following Table. All the energy values are mean energies with respect to the prevailing dose quantity. The dosimetry systems usually use electronic devices for the data evaluation and thus are often computer controlled. NOTE 1 In this standard, “dose” means personal or ambient dose equivalent, unless otherwise stated. NOTE 2 For Hp(10) and H*(10) no beta radiation is considered. Reasons: 1) Hp(10) and H*(10) are a conservative estimate for the effective dose which is not a suitable quantity for beta radiation. 2) No conversion coefficients are available in ICRU 56, ICRU 57 or ISO 6980. This standard is intended to be applied to dosimetry systems that are capable of evaluating doses in the required quantity and unit (Sv) from readout signals in any quantity and unit. The only correction that may be applied to the evaluated dose (indicated value) is the one resulting from natural background radiation using extra dosemeters. NOTE The correction due to natural background may be made before or after the dose calculation. In this standard, requirements are stated for minimal ranges of influence quantities, for example 80 keV to 1,25 MeV for photon energy (see Tables 3 to 5). A dosimetry system shall at least fulfil the requirements stated for these minimal ranges. However, the manufacturer may state larger ranges for the different influence quantities, for example 60 keV to 7 MeV. These larger ranges are called rated ranges. In such cases, the dosimetry systems must fulfil the requirements stated for these rated ranges. Thus, dosimetry systems can be classified by stating a set of ranges (for dose, energy, temperature etc.) within which the requirements stated in this standard are met (Capabilities of the system, see Clause 7). In addition, usage categories are given in Annex D with respect to different measuring capabilities.

IEC 62387-1:2007相似标准


推荐

医院射线诊断机与治疗机机房辐射防护工程建设

l        参考标准与文献(1) GJB2725-96校准测试实验室通用要求(2) GB16368-96生产使用密封的检验仪表放射防护要求(3) GB12162-90校准仪器参考辐射(4) 《电离辐射防护防护辐射源安全基本标准》GB18871-2002(5) 《中华人民共和国职业病防护法》2001(6) 卫生部、公安部16号令《放射管理办法》(7) 卫生部17号令《放射工作卫生防护管理办法...

检定/校验/校正/校准/内校/外校,分不清楚的看过来

电离辐射防护仪:射线监测仪、照射率仪、放射性表面污染仪、个人剂量计; 39. 活度计:活度计; 40. 激光能量、功率计(含医用激光源):激光能量计、激光功率计、医用激光源; 41. 超声功率计(含医用超声源):超声功率计、医用超声源; 42. 声级计:声级计; 43. 听力计:听力计; 44....

如何防核辐射

体表及衣服上放射性污染的测量要采用各种体表污染监测仪。   体内污染的测量可通过尿、血中的放射性含量的分析,再通过模式计算确定内照射剂量;还可直接通过全身计数器直接测定体内放射性核素的分布。   采用常规的外周血染色体及微核测定方法等生物剂量的测量方法可以推算人体的受照剂量。   在处置核与辐射突发事件的应急响应中,个人受照剂量检测是十分重要的,尤其是最早到达现场的人员的个人剂量监测。...

疾控局发布《疾病预防控制机构实验室仪器设备配置管理》等18项疾控标准

(CR)性能检测设备√√291中子剂量当量测量仪√√292中子射线个人剂量测量装置√293放射防护器材防护性能检测设备√294石材样品粉碎设备√295放射性气溶胶粒径测量装置√296全身计数器√297固体径迹探测装置√298微量铀分析仪√299人员放射性污染洗消装置√√300蛋白纯化仪√√301通风式试剂柜√√√302制冰机√√303紫外线照度测定仪√√√A  类B  类A  类B  ...