BS ISO 15724-2001
金属和其它无机涂层.钢的可扩散氢的电化测量.茗荷芥(Barnacle)电极法

Metallic and other inorganic coatings. Electrochemical measurement of diffusible hydrogen in steels. Barnacle electrode method


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 BS ISO 15724-2001 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
BS ISO 15724-2001
发布日期
2001年12月21日
实施日期
2001年12月21日
废止日期
中国标准分类号
A29
国际标准分类号
25.220.40
发布单位
GB-BSI
被代替标准
98/121309 DC-1998
适用范围
This International Standard describes a method that uses an electronic hydrogen detection instrument for measuring relative, diffusible hydrogen concentrations in bare steels or in plated steels after the coating has been removed. It is assumed that the hydrogen is uniformly distributed throughout a part. The method does not measure actual hydrogen concentration. However, oxidation current densities measured against time provide a useful indication of relative hydrogen concentrations and, therefore, the measurements can be used for comparison purposes. The method may be used as a quality control procedure as it does provide a quick means of measuring the effectiveness of pre- and/or post-plating heat treatments or of monitoring hydrogen uptake during plating or due to corrosion. It is important to note that the absence of failure in a particular test does not provide confirmation of complete elimination of hydrogen embrittlement because no one test method can provide all the data necessary to evaluate the degree of hydrogen degradation. For unplated parts the method is non-destructive; however, for plated parts the coating has to be removed prior to. measurement by a means proven not to damage the steel or to introduce hydrogen. This test method is limited to: — carbon and alloy steels, excluding austenitic stainless steels (see note 1); — flat specimens to which the cell can be attached (see note 2); — measurements at room temperature (25 ℃ ±1 ℃). NOTE 1 If this method is used for austenitic stainless steels and other face centred cubic (FCC) alloys, measurement times and interpretation of results will have to be determined because of the different kinetics involved. NOTE 2 For slightly curved surfaces it is essential to define an area that is reproducible. The area calculation will be different from that described in this International Standard. NOTE 3 The method can be applied to small parts, however, this necessitates some modification of the technique, procedure and interpretation of results.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号