IEEE 1776-2008
额定电压为 15000 V 及以下的机器采用模绕预绝缘定子线圈的交流电机的未密封或密封绝缘系统的热评估推荐规程

Recommended Practice for Thermal Evaluation of Unsealed or Sealed Insulation Systems for AC Electric Machinery Employing Form- Wound Pre-Insulated Stator Coils for Machines Rated 15 000 V and Below


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 IEEE 1776-2008 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “购买” 按钮开始采购(由第三方提供)。

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
IEEE 1776-2008
发布
2008年
发布单位
IEEE - The Institute of Electrical and Electronics Engineers@ Inc.
当前最新
IEEE 1776-2008
 
 
适用范围
This recommended practice outlines test procedures for comparing two or more unsealed or sealed insulation systems in accordance with their expected life at rated temperature. The procedure is limited to insulation systems for AC electrical machines using form-wound pre-insulated stator coils rated 15 000 V and below. The intent of this test procedure is to evaluate unsealed insulation systems for use with air cooling under usual (normal) service conditions@ or sealed insulation systems for use under severe environmental conditions (where the insulation is exposed to conducting contaminants). This procedure does not cover special requirements@ such as those for machines enclosed in gas atmospheres or machines subjected to strong chemicals@ metal dust or submersion in liquid@ etc. The procedure includes instructions for testing candidate systems in comparison with known reference systems@ of the same type@ having a proven record of service experience and interpreting the results of these tests. Purpose The purpose of this procedure is to classify unsealed or sealed insulation systems for the machinery used in usual (normal) service or machinery used in severe environmental conditions (and falling within the scope of this recommended practice) in accordance with their temperature capabilities by test@ rather than by chemical composition. Data from such tests may be used to establish the temperature classification of new insulation systems before they are service-proven. In order to provide data from which a base of reference for temperature classification can be established@ service-proven (reference) unsealed or sealed systems should also be tested according to this test procedure. This document combines the procedures given in IEEE Std 275 TM-1992 (for unsealed systems) with those of IEEE Std 429 TM-1994 (for sealed systems).1 1 IEEE Std 275-1992 and IEEE Std 429-1992 are withdrawn

IEEE 1776-2008相似标准


推荐

收藏:污水处理常用机械设备故障对照表

、测量转子三项开路电压7、在机座外部向定子铁芯钻孔加固螺栓电子全部局部过热1、电机过载2、2、电源电压过高过低3、3、定子铁芯部分硅钢片之间绝缘不良铁芯有毛刺4、转子运转时和定子相摩擦致使定子局部过热5、电机冷却效果不好6、6、定子绕组中有断路接地故障7、重换线圈电机,由于接线错误匝数错误8、缺相9、接点接触不良脱焊1、降低负载换一台大电机2、2、调整电压-5--+10%3、检修定子铁芯...

干货来了!!!污水处理设备管理与维护手册大全!

、测量转子三项开路电压7、在机座外部向定子铁芯钻孔加固螺栓电子全部局部过热1、电机过载2、2、电源电压过高过低3、3、定子铁芯部分硅钢片之间绝缘不良铁芯有毛刺4、转子运转时和定子相摩擦致使定子局部过热5、电机冷却效果不好6、6、定子绕组中有断路接地故障7、重换线圈电机,由于接线错误匝数错误8、缺相9、接点接触不良脱焊1、降低负载换一台大电机2、2、调整电压-5--+10%3、检修定子铁芯...

污水处理设备管理与维护手册,看完果断收藏了!

、测量转子三项开路电压7、在机座外部向定子铁芯钻孔加固螺栓电子全部局部过热1、电机过载2、2、电源电压过高过低3、3、定子铁芯部分硅钢片之间绝缘不良铁芯有毛刺4、转子运转时和定子相摩擦致使定子局部过热5、电机冷却效果不好6、6、定子绕组中有断路接地故障7、重换线圈电机,由于接线错误匝数错误8、缺相9、接点接触不良脱焊1、降低负载换一台大电机2、2、调整电压-5--+10%3、检修定子铁芯...