ISO 14253-2:2011
几何产品规范(GPS).工件和测量设备的测量检查.第2部分:几何产品规范测量中,测量设备校准中以及产品检验中不确定度评价指南

Geometrical product specifications (GPS) - Inspection by measurement of workpieces and measuring equipment - Part 2: Guidance for the estimation of uncertainty in GPS measurement, in calibration of measuring equipment and in product verification


标准号
ISO 14253-2:2011
发布
2011年
发布单位
国际标准化组织
替代标准
ISO 14253-2:2011/cor 1:2013
当前最新
ISO 14253-2:2011/cor 1:2013
 
 
引用标准
ISO 14253-1:1998 ISO 14660-1:1999 ISO/IEC Guide 98-3:2008 ISO/IEC Guide 99:2007
适用范围
This part of ISO 14253 gives guidance on the implementation of the concept of the “Guide to the estimation of uncertainty in measurement” (in short GUM) to be applied in industry for the calibration of (measurement) standards and measuring equipment in the field of GPS and the measurement of workpiece GPS characteristics. The aim is to promote full information on how to achieve uncertainty statements and provide the basis for international comparison of measurement results and their uncertainties (relationship between purchaser and supplier). This part of ISO 14253 is intended to support ISO 14253-1. Both parts are beneficial to all technical functions in a company in the interpretation of GPS specifications [i.e. tolerances of workpiece characteristics and values of maximum permissible errors (MPEs) for metrological characteristics of measuring equipment]. This part of ISO 14253 introduces the Procedure for Uncertainty MAnagement (PUMA), which is a practical, iterative procedure based on the GUM for estimating uncertainty of measurement without changing the basic concepts of the GUM. It is intended to be used generally for estimating uncertainty of measurement and giving statements of uncertainty for: ⎯ single measurement results; ⎯ the comparison of two or more measurement results; ⎯ the comparison of measurement results — from one or more workpieces or pieces of measurement equipment — with given specifications [i.e. maximum permissible errors (MPEs) for a metrological characteristic of a measurement instrument or measurement standard, and tolerance limits for a workpiece characteristic, etc.], for proving conformance or non-conformance with the specification. The iterative method is based basically on an upper bound strategy, i.e. overestimation of the uncertainty at all levels, but the iterations control the amount of overestimation. Intentional overestimation — and not underestimation — is necessary to prevent wrong decisions based on measurement results. The amount of overestimation is controlled by economical evaluation of the situation. The iterative method is a tool to maximize profit and minimize cost in the metrological activities of a company. The iterative method/procedure is economically self-adjusting and is also a tool to change/reduce existing uncertainty in measurement with the aim of reducing cost in metrology (manufacture). The iterative method makes it possible to compromise between risk, effort and cost in uncertainty estimation and budgeting.

ISO 14253-2:2011相似标准


推荐

86项不确定相关现行有效标准和文件大全!

GB/T 34876-2017真空技术真空计与标准真空计直接比较校准结果不确定评定GB/T 34879-2017产品几何技术规范(GPS)光学共焦显微镜计量特性及测量不确定评定导则GB/T 34881-2017产品几何技术规范(GPS)坐标测量检测不确定评估指南GB/Z 6113.401-2018无线电骚扰抗扰测量设备测量方法规范4-1部分不确定、统计学限值建模标准化EMC...

实验室检验检测设备--三坐标测量

发动机是由许多各种形状零部件组成,这些零部件制造质量直接关系到发动机性能寿命。因此,需要在这些零部件生产中进行非常精密检测,以保证产品精度及公差配合。在传统测量方法选择上,人们主要依靠两种测量手段完成对箱体类工件复杂几何形状工件测量,即:通过三坐标测量机执行箱体类工件检测;通过专用测量设备,例如专用齿轮检测仪、专用凸轮检测设备等完成具有复杂几何形状工件测量。...

如何选购三坐标测量仪器

需要考察关键部分一旦你确定了如何以及在何处使用测量机,有一些关键性能需要进行考察,这包括了测量不确定工作效率。 根据现行国际标准,对于测量不确定检测程序在ISO 10360进行了描述。A. 长度测量zui大允许示值误差 MPEE (ISO 10 360-2 )在测量空间任意7种不同方位,测量一组5种尺寸量块,每种量块长度分别测量3次。...

310项推荐性国家标准5项国家标准修改单公告