ASTM C1777-2015
采用比色计快速测定细骨料或矿物填料亚甲蓝值的标准试验方法

Standard Test Method for Rapid Determination of the Methylene Blue Value for Fine Aggregate or Mineral Filler Using a Colorimeter


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 ASTM C1777-2015 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
ASTM C1777-2015
发布日期
2015
实施日期
废止日期
国际标准分类号
91.100.15
发布单位
US-ASTM
适用范围

5.1x00a0;This test method is used to determine rapidly the amount of methylene blue adsorbed by a specimen of fine aggregate or mineral filler. The result is reported as a methylene blue value in units of mg of methylene blue adsorbed per g of fine aggregate or mineral filler. The methylene blue value is a function of the amount and characteristics of clay minerals present in the test specimen. High methylene blue values indicate increased potential for diminished fine aggregate or mineral filler performance in a cementitious mixture due to the presence of clays.

Note 1:x00a0;Results from this test method are not expected to be correlated with those obtained using AASHTO T 330 or EN 933-9. These three test methods are likely to give very different numerical values even though the units are the same. The AASHTO T 330 test is performed only on the fraction of an aggregate passing the 75 x03bc;m sieve, the EN 933-9 test is performed only on the fraction finer than 2 mm, and this test is performed on the fraction finer than the 4.75 mm sieve. Therefore, when testing the same fine aggregate source, the AASHTO test method would give the highest methylene blue value because any clay present in the specimen would be concentrated in the fraction finer than the 75 x03bc;m sieve. The AASHTO and EN test methods do not take into account the amount of material passing the 75 x03bc;m sieve or 2 mm sieve, respectively. For example, a fine aggregate with high methylene blue value measured by the AASHTO method but low percentage passing the 75 x03bc;m sieve may have less effect on concrete performance than a fine aggregate with low methylene blue value measured by the AASHTO method but a high percentage passing the 75 x03bc;m sieve. In contrast, this test method expresses methylene blue value based on the entire fine aggregate or mineral filler specimen. Additionally, the AASHTO and EN test methods use titration to determine the amount of methylene blue of known concentration that is adsorbed by a specimen and require the operator to visually determine the end point of the test. In contrast, this test method uses a colorimeter to detect the change in concentration of methylene blue solution before and after being mixed with the fine aggregate or mineral filler specimen.

Note 2:x00a0;Recommendations for maximum methylene blue values for specific applications are not provided in this test method. Maximum methylene blue values should be established based on successful performance of fine aggregate or mineral filler in the applications under consideration.

1.1x00a0;This test method provides a rapid test to determine the amount of methylene blue adsorbed by a specimen of fine aggregate or mineral filler and can be used both in the laboratory and in the field.

1.2x00a0;The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3x00a0;This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health pract......





Copyright ©2007-2016 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号