07.100.10 医学微生物学 标准查询与下载



共找到 194 条与 医学微生物学 相关的标准,共 13

1.1 These test methods cover the determination of the nutrient-holding capacity and the toxic or nutritive effect on bacterial growth of organisms retained on a membrane filter, when the absorbent pad being tested is used as a nutrient reservoir and medium supply source for the retained bacteria. 1.2 The tests described are conducted on 47-mm diameter disks, although other size disks may be employed for bacterial culture techniques. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Evaluating Absorbent Pads Used with Membrane Filters for Bacteriological Analysis and Growth (Withdrawn 2020)

ICS
07.100.10
CCS
发布
2011-06-01
实施

The technique produces a chemical-precipitation reaction between the phencyclidine or its analogues and the precipitating reagent. The habit and the aggregation of the crystals formed may be used to distinguish phencyclidine or its analogues from other drugs. The technique can be utilized on phencyclidine or its analogues present in either the salt or free base form. The technique does not distinguish between salt and free base forms.1.1 This guide describes some standard procedures applicable to the analysis of phencyclidine and its analogues using microcrystal tests (1-8). 1.2 These procedures are applicable to phencyclidme and its analogues which are present in solid dosage form or in a liquid form. They are not typically applicable to the analysis of phencyclidine and its analogues in biological samples. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard cannot replace knowledge, skill, or ability acquired through appropriate education, training, and experience and should be used in conjunction with sound professional judgment. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Guide for Microcrystal Testing in the Forensic Analysis of Phencyclidine and Its Analogues

ICS
07.100.10
CCS
发布
2011-03-01
实施

This standard applies to cultural investigations for the detection of mycobacteria.

Medical microbiology - Diagnosis of tuberculosis - Part 3: Detection of mycobacteria by culture methods; Text in German and English

ICS
07.100.10
CCS
C05
发布
2011-03
实施

The standard applies to the handling of control strains of the mycobacteria genus. Control strains are used for the purposes of quality assurance. Thus, this standard is used in all mycobacteriological diagnostic laboratories in accordance with DIN 58956-1 or in laboratories in which equipment, culture media, reagents, tst components, test kits and other diagnostic agents for the detection of mycobacteria are examined.

Medical microbiology - Quality management in medical microbiology - Part 17: Requirements for the use of control strains for the examination of mycobacteria; Text in German and English

ICS
07.100.10
CCS
C05
发布
2011-03
实施

This standard applies to the molecular-biological differentiation of cultures of tubercle bacilli (M. tuberculosis complex). It does not cover the application on direct materials.

Medical microbiology - Diagnosis of tuberculosis - Part 5: Molecularbiological identification and differentiation of tubercle bacilli; Text in German and English

ICS
07.100.10
CCS
C05
发布
2011-03
实施

The project applies to microscopic examinations for the purpose of detecting mycobacteria in human specimens.

Medical microbiology - Diagnosis of tuberculosis - Part 32: Detection of mycobacteria by microscopic methods; Text in German and English

ICS
07.100.10
CCS
C05
发布
2011-03
实施

Medical microbiology - Diagnosis of tuberculosis - Part 4: Primary samples for the diagnosis of tuberculosis and mycobacteria - Qualitative and quantitative requirements, extraction, transport and storage - Supplement 1: Prevention of contaminations of cl

ICS
07.100.10
CCS
C05
发布
2011-03
实施

Biosafety Cabinetry: Design, Construction, Performance and Field Certification

ICS
07.100.10
CCS
C50
发布
2011
实施

Biosafety Cabinetry: Design, Construction, Performance and Field Certification

ICS
07.100.10
CCS
C50
发布
2011
实施

Biosafety Cabinetry: Design, Construction, Performance and Field Certification

ICS
07.100.10
CCS
C50
发布
2011
实施

4.1 This test method is useful for assessing the cytotoxic potential of new materials and formulations and as part of a quality control program for established medical devices and components. 4.2 This test method assumes that assessment of cytotoxicity provides useful information to aid in predicting the potential clinical applications in humans. Cell culture methods have shown good correlation with animal assays and are frequently more sensitive to cytotoxic agents. 4.3 This cell culture test method is suitable for incorporation into specifications and standards for materials to be used in the construction of medical devices that are to be implanted into the human body or placed in contact with tissue fluids or blood on a long-term basis. 4.4 Some biomaterials with a history of safe clinical use in medical devices are cytotoxic. This test method does not imply that all biomaterials must pass this assay to be considered safe for clinical use (Practice F748). 1.1 This test method is appropriate for materials in a variety of shapes and for materials that are not necessarily sterile. This test method would be appropriate in situations in which the amount of material is limited. For example, small devices or powders could be placed on the agar and the presence of a zone of inhibition of cell growth could be examined. 1.1.1 This test method is not appropriate for leachables that do not diffuse through agar or agarose. 1.1.2 While the agar layer can act as a cushion to protect the cells from the specimen, there may be materials that are sufficiently heavy to compress the agar and prevent diffusion or to cause mechanical damage to the cells. This test method would not be appropriate for these materials. 1.2 The L-929 cell line was chosen because it has a significant history of use in assays of this type. This is not intended to imply that its use is preferred, only that the L-929 is an established cell line, well characterized and readily available, that has demonstrated reproducible results in several laboratories. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Agar Diffusion Cell Culture Screening for Cytotoxicity

ICS
07.100.10
CCS
发布
2011
实施

Medical microbiology - Susceptibility testing of pathogens to antimicrobial agents - Part 4: Evaluation classes of the minimum inhibitory concentration; Supplement 1: MIC-breakpoints of antibacterial agents

ICS
07.100.10
CCS
C05
发布
2010-05
实施

Biosafety Cabinetry: Design, Construction, Performance, and Field Certification

ICS
07.100.10
CCS
Y80
发布
2010
实施

Biosafety Cabinetry: Design, Construction, Performance, and Field Certification

ICS
07.100.10
CCS
C44
发布
2010
实施

NSF/ANSI - 49 - Biosafety Cabinetry: Design, Construction, Performance and Field Certification

ICS
07.100.10
CCS
C44
发布
2010
实施

Biosafety Cabinetry: Design, Construction, Performance, and Field Certification

ICS
07.100.10
CCS
C04
发布
2010
实施

The purpose of these specifications is to allow for comparable (i.e. repeatable and reproducible) results to be obtained when determining the minimum bactericidal concentration by means of microdilution.

Medical microbiology - Susceptibility testing of microbial pathogens to antimicrobial agents - Part 7: Determination of the minimum bactericidal concentration (MBC) with the method of microbouillondilution; Text in German and English

ICS
07.100.10
CCS
C05
发布
2009-08
实施

Describes a method to determine the bacteriostatic efficacy of water miscible liquids.

Bacteriostatic efficacy of water miscible liquids

ICS
07.100.10
CCS
Y43
发布
2009-04-17
实施

Describes a method to determine the antibacterial efficacy of solid and semi-solid antiseptics.

Antibacterial efficacy of solid and semi-solid antiseptics

ICS
07.100.10
CCS
G70
发布
2009-04-17
实施

This standard applies to the determination of the drug susceptibility of tubercle bacilli whose growth on the culture medium used is sufficient for evaluation. This standard specifies a method that is considered to be the reference method and to which other methods for the determination of the drug susceptibility of tubercle bacilli shall be adjusted.

Medical microbiology - Diagnosis of tuberculosis - Part 8: Methods for the determination of susceptibility of tubercle bacilli to chemotherapeutic agents; Text in German and English

ICS
07.100.10
CCS
C05
发布
2009-04
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号