11.060.15 牙科植入物 标准查询与下载



共找到 145 条与 牙科植入物 相关的标准,共 10

Dentistry ― Membrane materials for guided tissue regeneration in oral and maxillofacial surgery ― Contents of a technical file

ICS
11.060.15
CCS
发布
2019-11-25
实施

Dentistry — Torsion test of implant body/connecting part joints of endosseous dental implant systems

ICS
11.060.15
CCS
发布
2019-11-25
实施

Dentistry — Screw loosening test using cyclic torsional loading for implant body/implant abutment connection of endosseous dental implants

ICS
11.060.15
CCS
发布
2019-11-25
实施

Dentistry — Implants — Dynamic loading test for endosseous dental implants

ICS
11.060.15
CCS
发布
2019-11-25
实施

Dentistry — Torsion test of implant body/connecting part joints of endosseous dental implant systems

ICS
11.060.15
CCS
发布
2019-11-25
实施

Dentistry ― Membrane materials for guided tissue regeneration in oral and maxillofacial surgery ― Contents of a technical file

ICS
11.060.15
CCS
发布
2019-11-25
实施

Dentistry — Minimal dental implant data set for clinical use

ICS
11.060.15
CCS
发布
2019-11-25
实施

Dentistry — Implants — Clinical performance of hand torque instruments

ICS
11.060.15
CCS
发布
2018-11-05
实施

Dentistry — Contents of technical file for dental implant systems

ICS
11.060.15
CCS
发布
2018-11-05
实施

Dentistry — Implants — Clinical performance of hand torque instruments

ICS
11.060.15
CCS
发布
2018-11-05
实施

Dentistry — Contents of technical file for dental implant systems

ICS
11.060.15
CCS
发布
2018-11-05
实施

This document specifies the classification, requirements, and test methods for artificial teeth such as ceramic teeth and polymer teeth that are industrially manufactured for use in dental prostheses.

Dentistry - Artificial teeth for dental prostheses (ISO 22112:2017); German version EN ISO 22112:2017

ICS
11.060.15
CCS
C33
发布
2017-11-01
实施

Dentistry - Implants - Dynamic loading test for endosseous dental implants (ISO 14801:2016); German version EN ISO 14801:2016

ICS
11.060.15
CCS
C33
发布
2017-03
实施

This Technical Specification establishes a method to determine the torsional yield strength and maximum torque of the implant body/connecting part joints of endosseous dental implant systems. This test is most appropriate for evaluating new types of joints and connecting parts, as well as new materials. This Technical Specification provides a protocol for torsional loading of an implant body/connecting part joint. It is not applicable for predicting the in vivo performance of an endosseous dental implant system and it is not derived from observations of clinical failure.

Dentistry -- Torsion test of implant body/connecting part joints of endosseous dental implant systems

ICS
11.060.15
CCS
发布
2016-12-22
实施

This International Standard specifies the minimal data set to be recorded for a patient receiving dental implant treatment. This will comprise the locations and types of dental implant bodies, connecting components and adjunctive devices, including grafting materials, placed in a patient’s jaw(s). This information will be recorded by the responsible clinician in the patient's file and should be made available to the patient by the clinician(s) who provided the care.

Dentistry -- Minimal dental implant data set for clinical use

ICS
11.060.15
CCS
发布
2016-12-22
实施

This International Standard gives the requirements for a technical file on the evaluation of the chemical, physical, mechanical, biological and clinical aspects and behaviour of membrane materials, whether resorbable, partially resorbable or non-resorbable, which are used — for guided tissue regeneration in oral and maxillofacial surgery to correct a morphological defect or abnormality, — in contact with teeth and/or dental implants, — for prevention of epithelial migration in periodontal surgery, — for the augmentation of bone prior to the planned insertion of dental implants, — and/or for augmentation of bone for stabilization of dental prostheses. This International Standard is not applicable to materials whose primary intended use is to deliver a medicinal product, autografts and allografts, or materials intended to act through pharmacological, immunological or metabolic means.

Dentistry -- Membrane materials for guided tissue regeneration in oral and maxillofacial surgery -- Contents of a technical file

ICS
11.060.15
CCS
发布
2016-12-22
实施

Operating procedures for the use of miniscrew implants in orthodontic treatment

ICS
11.060.15
CCS
C 33
发布
2016-12-09
实施
2017-03-01

Dentistry - Designation system for dental implants (ISO 19429:2015); German version EN ISO 19429:2016

ICS
11.060.15
CCS
发布
2016-12
实施

Dentistry. Implants. Dynamic loading test for endosseous dental implants

ICS
11.060.15
CCS
C33
发布
2016-11-30
实施
2016-11-30

This International Standard specifies a method of dynamic testing of single post endosseous dental implants of the transmucosal type in combination with their premanufactured prosthetic components. It is most useful for comparing endosseous dental implants of different designs or sizes. This International Standard is not a test of the fundamental fatigue properties of the materials from which the endosseous implants and prosthetic components are made. This International Standard is not applicable to dental implants with endosseous lengths shorter than 8 mm nor to magnetic attachments. While this International Standard simulates the functional loading of an endosseous dental implant under “worst case” conditions, it is not applicable for predicting the in vivo performance of an endosseous dental implant or dental prosthesis, particularly if multiple endosseous dental implants are used for a dental prosthesis.

Dentistry - Implants - Dynamic loading test for endosseous dental implants

ICS
11.060.15
CCS
C33
发布
2016-11
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号