11.060.15 牙科植入物 标准查询与下载



共找到 145 条与 牙科植入物 相关的标准,共 10

This International Standard specifies a method of dynamic testing of single post endosseous dental implants of the transmucosal type in combination with their premanufactured prosthetic components. It is most useful for comparing endosseous dental implants of different designs or sizes. This International Standard is not a test of the fundamental fatigue properties of the materials from which the endosseous implants and prosthetic components are made. This International Standard is not applicable to dental implants with endosseous lengths shorter than 8 mm nor to magnetic attachments. While this International Standard simulates the functional loading of an endosseous dental implant under “worst case” conditions, it is not applicable for predicting the in vivo performance of an endosseous dental implant or dental prosthesis, particularly if multiple endosseous dental implants are used for a dental prosthesis.

Dentistry - Implants - Dynamic loading test for endosseous dental implants

ICS
11.060.15
CCS
C33
发布
2016-11
实施

Dentistry - Designation system for dental implants

ICS
11.060.15
CCS
发布
2016-09-30
实施
2016-09-30

Dentistry - Preclinical evaluation of dental implant systems - Animal test methods

ICS
11.060.15
CCS
发布
2016-07-00
实施

Diese Internationale Norm beschreibt ein System, das die Position des Implanatkörpers im Kiefer bezeichnet und das zur Anwendung mit dem in ISO 3950 beschriebenen Schema vorgesehen ist. Es zeigt nicht selbst an, ob das Produkt in der Mundhöhle sichtbar ist oder das Vorhandensein transmukosaler Bestandteile oder Implantatrestaurationen. Weil das System Positionen beschreibt, jedoch keine Restaurationsformen, ist es nicht notwendig die Quadranten Bezeichnungsnummern 5 bis 8, die angewandt werden, um einen Milchzahn anzugeben, zu verwenden. Diese Angaben sollten vom zuständigen Kliniker in der Patientenakte aufgezeichnet werden und vom/von den Kliniker(n) der die Behandlung durchführt dem Patienten zur Verfügung gestellt werden.

Dentistry - Designation system for dental implants

ICS
11.060.15
CCS
C33
发布
2016-06
实施

Dentistry. Screw loosening test using cyclic torsional loading for implant body/implant abutment connection of endosseous dental implants

ICS
11.060.15
CCS
发布
2016-05-31
实施
2016-05-31

Dentistry - Screw loosening test using cyclic torsional loading for implant body/implant abutment connection of endosseous dental implants

ICS
11.060.15
CCS
C33
发布
2016-05-01
实施

  Scope is not provided for this standard

Dentistry -- Implantable materials for bone filling and augmentation in oral and maxillofacial surgery -- Contents of a technical file

ICS
11.060.15
CCS
发布
2015-12-21
实施

ISO 14801:2007 specifies a method of fatigue testing of single post endosseous dental implants of the transmucosal type and their premanufactured prosthetic components. It is most useful for comparing endosseous dental implants of different designs or sizes. While it simulates the functional loading of an endosseous dental implant body and its premanufactured prosthetic components under “worst case” conditions, ISO 14801:2007 is not applicable for predicting the in vivo performance of an endosseous dental implant or prosthesis, particularly if multiple endosseous dental implants are used for a prosthesis.

Dentistry -- Implants -- Dynamic fatigue test for endosseous dental implants

ICS
11.060.15
CCS
发布
2015-12-21
实施

  Scope is not provided for this standard

Dentistry -- Contents of technical file for dental implant systems

ICS
11.060.15
CCS
发布
2015-12-21
实施

  Scope is not provided for this standard

Dentistry -- Implants -- Clinical performance of hand torque instruments

ICS
11.060.15
CCS
发布
2015-12-21
实施

  Scope is not provided for this standard

Dentistry -- Preclinical evaluation of dental implant systems -- Animal test methods

ICS
11.060.15
CCS
发布
2015-12-21
实施

Dentistry - Magnetic attachments - Amendment 1 (ISO 13017:2012/Amd 1:2015)

ICS
11.060.15
CCS
C33
发布
2015-12
实施

Dentistry. Designation system for dental implants

ICS
11.060.15
CCS
发布
2015-10-31
实施
2015-10-31

This International Standard provides a system for designating the location of an implant body within a jaw, and is intended for use with the scheme described in ISO 3950. It does not in itself indicate whether the device is visible within the oral cavity or the presence of transmucosal components or implant restorations. Since the system describes location but not restoration form, it is not necessary to use the quadrant designation numbers 5 to 8 which are employed when indicating a primary tooth. This information should be recorded by the responsible clinician in the patient’s file and made available to the patient by the clinician(s) who provided the care.

Dentistry - Designation system for dental implants

ICS
11.060.15
CCS
C33
发布
2015-10
实施

Dentistry — Orthodonticmetallic mini screw — Test methods of torque and multiangularpull-out strength

ICS
11.060.15
CCS
C48
发布
2015-07-31
实施

Dentistry — Orthodonticmetallic mini screw — Test methods of torque and multiangularpull-out strength

ICS
11.060.15
CCS
发布
2015-07-31
实施

Dentistry-Preclinical evaluation of dental implant systems-Animal test methods

ICS
11.060.15
CCS
发布
2014-12-01
实施
2014-12-01

Dentistry-Preclinical evaluation of dental implant systems-Animal test methods

ICS
11.060.15
CCS
发布
2014-12-01
实施

Dynamic fatigue test method for endosseous dental implants

ICS
11.060.15
CCS
C33
发布
2013-09-01
实施

Contents of technical file for dental implant systems

ICS
11.060.15
CCS
C33
发布
2013-09-01
实施