Specifications for filling in the original record form of lightning protection device testing and compiling the report

ICS
13.260
CCS
K 09
发布
2023-05-16
实施
2023-07-16

Standard Terminology Relating to Electrical Protective Equipment for Workers

ICS
13.260
CCS
发布
2023-05-01
实施

1.1 This specification covers insulating rods and foam-filled tubes made from fiberglass-reinforced plastic (FRP) that are intended for use in live line tools. 1.2 This specification does not include insulating foamfilled tubes and rods from other materials. Specifications for fittings and attachments to rods and foam-filled tubes for complete tools are not covered in this specification. 1.3 This specification establishes the technical characteristics that the tubes and rods must satisfy. 1.4 The following safety hazards caveat pertains only to the test method portion, Section 12, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Fiberglass-Reinforced Plastic (FRP) Rod and Tube Used in Live Line Tools 

ICS
13.260
CCS
发布
2022-12-01
实施

IEC 60364-5-52:2009 deals with the selection and erection of wiring systems. This third edition cancels and replaces the second edition, published in 2001, and constitutes a technical revision. The main changes with respect to the previous edition are as follows: - Subclause 521.4 introduces minor changes with regard to busbar trunking systems and powertrack systems. - Subclause 523.6 introduces minor changes with regard to the sizing of cables where harmonic currents are present. - A new sublause 523.9 concerning single-core cables with a metallic covering has been introduced. - Clause 525 introduces changes in the maximum value of voltage drop permitted between the origin of the consumer's installation and the equipment which should not be greater than that given in the relevant annex. - Clause 526 introduces minor changes to electrical connections including additional exceptions for inspection of connections and additional notes. - Clause 528 introduces additional requirements with regard to proximity of underground power and telecommunication cables. - Clause 529 introduces minor changes to selection and erection of wiring systems in relation to maintainability, including cleaning.

Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems

ICS
13.260
CCS
发布
2022-11-25
实施
2023-02-25 (7)

1.1 This test method is used to determine the heat attenuation factor (HAF), the effective heat attenuation factor (EHAF), and the shields mechanical strength (SMS) of a shield attached on live line tools or racking rods intended for protection of workers exposed to electric arcs. 1.2 The materials used in this test method of worker protection are in the form of a shield attached on live line tools or on the racking rods. 1.3 The protective shield described in this test method shall be transparent and shall be easily attached and removed from live line tools or from racking rods. 1.4 The protective shield described in this test method has 24-in. (0.61-m) diameter and can be used for most applications, however for special cases, the shield can have different sizes to suit the protective requirements of the application. 1.5 This standard shall be used to measure and describe the properties of materials, products, or assemblies in response to incident energies (thermal-convective, and radiant and pressure wave) generated by an electric arc under controlled laboratory conditions and does not purport to predict damage from light, resultant pressure impact other than the pressure and thermal aspects measured. 1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.7 This standard shall not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire assessment, which takes into account all of the factors, which are pertinent to an assessment of the fire hazard of a particular end use. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.For specific precautions, see Section 7. 1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Determining the Protective Performance of a Shield Attached on Live Line Tools or on Racking Rods for Electric Arc Hazards

ICS
13.260
CCS
发布
2022-11-01
实施

Standard Terminology Relating to Electrical Protective Equipment for Workers

ICS
13.260
CCS
发布
2022-11-01
实施

1.1 This guide provides recommendations for in-service inspection, maintenance, and electrical testing of hand-held insulating live-line tools. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Guide for In-Service Inspection, Maintenance, and Electrical Testing of Hand-Held Live-Line Insulating Tools (Fiberglass-Reinforced Plastic (FRP))

ICS
13.260
CCS
发布
2022-11-01
实施

以维护社会公共安全为目的,运用安全防范产品和其他相关产品所构成的入侵报警系统、视频安防监控系统、出入口控制系统、防爆安全检查系统等;或由这些系统为子系统组合或集成的电子系统或网络。

Technical specification for isolated lightning protection and grounding device for security protection system

ICS
13.260
CCS
I6540
发布
2022-08-05
实施
2022-08-08

1.1 This practice identifies protocols for use in conducting arc testing on finished products intended for use as thermal protection by workers who may be exposed to electric arc hazards. 1.1.1 The practice is also used for other components which can be exposed to electric arc, but which do not require an arc rating. 1.1.1.1 If items are tested and they do not meet the appropriate standard, it is the responsibility of the specimen submitter to provide this information for indication in the test report. 1.2 Arc Rated protective items are typically tested using this practice to evaluate the performance of the interface area between the product and the other arc flash PPE or to evaluate zippers and other findings. 1.3 This practice does not establish an arc rating for any product. Other ASTM test methods are to be used when applicable such as ASTM F1959/F1959M, F2178, and F2675. 1.4 This practice is not intended to produce an arc rating and does not replicate in all types of arc exposures. 1.5 This practice is used with the following standards: 1.5.1 Protective fabric materials receive arc ratings from Test Method F1959/F1959M. 1.5.2 Face protective products receive arc ratings from Test Method F2178. 1.5.3 Gloves receive arc ratings from Test Method F2675. 1.5.4 Rainwear materials, findings and closures are specified by Specification F1891. 1.5.5 Garments are specified by Specification F1506. 1.6 The test specimens used in this practice are typically in the form of arc-rated finished products. These arc-rated finished products may include, but are not limited to, single layer garments, multi-layer garments or ensembles, cooling vests, gloves, sleeves, chaps, rainwear, balaclavas, faceshields, and hood assemblies with hood shield windows. Non-arc rated finished products may be included when part of a flameresistant system, or for evaluating heat transmission through the finished product for incident reenactment, or for evaluation of products needed but not available as arc rated (such as respirators, etc.) 1.7 The arc rated finished product specimens are new products as sold or products which have been used for the intended purpose for a designated time. 1.8 This practice is used to determine the response characteristics or design integrity of arc-rated materials, products, or assemblies in the form of finished products when exposed to radiant and convective energy generated by an electric arc under controlled laboratory conditions. 1.9 This practice can be used to determine the integrity of closures and seams in arc exposures, the protective performance of arc-rated products in areas where garment overlap occurs or where heraldry reflective trim or other items are used, and response characteristics such as afterflame time, melting, dripping, deformation, shrinkage, ignition, or other damage, or combination thereof, of fabrics, systems of fabrics, flammable undergarments when included as part of a system, sewing thread, findings, and closures. 1.10 This practice can be used for incident reenactment, training demonstrations, and material/design comparisons. 1.11 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined. 1.12 This standard shall not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire assessment, which takes into account all of the factors, which are pertinent to an assessment of the fire hazard of a particular end use. 1.13 This standard does not purport to describe or appraise the effect of the electric arc fragmentation explosion and subsequent molten metal splatter, which involves the pressure 1 This practice is under the jurisdiction of ASTM Committee F18 on Electrical Protective Equipment for Workers and is the direct responsibility of Subcommittee F18.65 on Wearing Apparel. Current edition approved April 1, 2022. Published May 2022. Originally approved in 2006. Last previous edition approved in 2021 as F2621 – 21. DOI: 10.1520/F2621_F2621M-22. Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. 1 wave containing molten metals and possible fragments of other materials except to the extent that evidence of projectile damage is assessed and reported. 1.14 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautions, see Section 7. 1.15 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Evaluating Response Characteristics of Safety Products in an Electric Arc Exposure

ICS
13.260
CCS
发布
2022-04-01
实施

Low-voltage electrical installations -- Part 4-41: Protection for safety -- Protection against electric shock

ICS
13.260
CCS
发布
2022-03-22
实施

1.1 This performance specification identifies minimum performance requirements to determine the (a) arc rating of fabrics, (b) flame resistance of fabrics and subassemblies, (c) mechanical durability of the fabrics and subassemblies, (d) the minimum garment construction and performance requirements, and (e) the garment labeling requirements for the completed protective clothing worn by workers exposed to flames and electric arcs. 1.1.1 The minimum requirements for garment labeling are intended to provide end users with adequate information to select garments with the appropriate arc rating. 1.1.2 End users are required to perform an assessment to determine the level of hazard and the required arc rating of the protective clothing for their individual hazards. 1.1.2.1 The end user risk assessments are outside the scope of this standard. 1.2 This performance specification does not address coated or laminated protective clothing commonly used for rainwear applications in an arc hazard environment. Performance requirements related to this category of protective clothing are detailed in Specification F1891. 1.3 This performance specification does not address hand protection. Performance and test requirements related to hand protection are detailed in OSHA 1910.138, Specification D120, and Test Method F2675/F2675M. 1.4 The care and maintenance requirements for laundering electric arc flash protective clothing are outside the scope of this standard. Refer to Guides F1449 or F2757 related to industrial or home laundering. 1.5 This standard should be used to evaluate and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions. It should not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions. 1.5.1 The results of this evaluation may be used as elements of a fire-risk assessment that takes into account all of the factors that are pertinent to an assessment of the fire hazard of a particular end use. 1.6 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.7 The following precautionary caveat pertains only to the test methods portion, Section 7, of this performance specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Performance Specification for Flame Resistant and Electric Arc Rated Protective Clothing Worn by Workers Exposed to Flames and Electric Arcs

ICS
13.260
CCS
发布
2022-03-01
实施

本文件规定了文物建筑雷击风险评估的术语和定义、基本要求、雷电环境评价、评估模型、风险分析计算方法、评估过程。 本文件适用于古建筑、近现代代表性建筑、革命旧址的单体文物建筑和多个单体文物建筑构成的建筑群的雷击风险评估。

Technical specification for lightning risk assessment of historical and cultural relic buildings

ICS
13.260
CCS
M7410
发布
2022-02-18
实施
2022-02-18

1.1 This specification covers the in-service care, inspection, testing, and use voltage of insulating blankets for protection of workers from accidental contact with live electrical conductors, apparatus, or circuits. The product requirements and acceptance testing are as shown in Specification D1048. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.See Section 6 and 8.2 for specific precautionary statements. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for In-Service Care of Insulating Blankets

ICS
13.260
CCS
发布
2022-02-01
实施

1.1 This specification covers manufacturing and testing of rubber insulating gloves for protection of workers from electrical shock. 1.2 Two types of gloves are provided and are designated as Type I, non-resistant to ozone, and Type II, resistant to ozone. 1.3 Six classes of gloves, differing in electrical characteristics, are provided and are designated as Class 00, Class 0, Class 1, Class 2, Class 3, and Class 4. 1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard. See IEEE/ASTM SI 10. 1.5 The following safety hazards caveat pertains only to the test method portion, Sections 16, 17, 18, and 19, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific warning statement, see 18.2. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Rubber Insulating Gloves

ICS
13.260
CCS
发布
2022-02-01
实施

Standard Practice for Determining Response Characteristics and Design Integrity of Arc Rated Finished Products and Evaluating other Products in an Electric Arc Exposure

ICS
13.260
CCS
发布
2021-11-01
实施

Live working - Conductive clothing ((IEC 60895:2020) EN IEC 60895:2020) (german version)

ICS
13.260
CCS
发布
2021-10-01
实施
2021-10-01

Power Distribution Room Safety Management Specifications

ICS
13.260
CCS
K09
发布
2021-09-24
实施
2022-01-01

High-voltage switchgear and controlgear. Phase comparator used with VDIS

ICS
13.260
CCS
发布
2021-09-09
实施
2021-09-09

Live working – Methods for assessment of defects and verification of performance applicable to tools, devices and equipment

ICS
13.260
CCS
发布
2021-09-03
实施
2021-09-03

High-voltage switchgear and controlgear – Part 215: Phase comparator used with VDIS

ICS
13.260
CCS
发布
2021-09-03
实施
2021-09-03