23.040.50 (Pipes and fittings of other materials) 标准查询与下载



共找到 346 条与 相关的标准,共 24

1.1 This specification covers nonreinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts.1.2 This specification is the metric counterpart of Specification C 14.Note 18212;This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of pipe specified and provide for or require inspection at the construction site.

Standard Specification for Concrete Sewer, Storm Drain, and Culvert Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2005
实施

1.1 This specification covers requirements relating to asbestos-cement nonpressure sewer pipe, joints, and fittings suitable for use with gravity flow, intended for sewerage and drainage applications from point of use to point of treatment or disposal. It defines certain conditions of manufacture, classification, characteristics, and acceptance tests applicable to these products.1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are provided for information only. Note 1Rubber rings suitable for use with this pipe are covered in Specification D 1869.Note 2As general guidance to achieve safe and clean construction-site conditions when working with asbestos-cement pipe products, the procedures covered in AWWA No. M-16 shall be followed.Note 3This specification is issued for product standardization and purchasing purposes only, and does not include requirements for installation or the relationships between operating conditions and the strength characteristics of the various classifications of pipe. The purchaser is cautioned that he must correlate installation and operating conditions with the specified characteristics of the pipe.1.3 Warning-Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products minimize the dust that results. For information on the safe use of chrysoltile asbestos, refer to "Safe Use of Chrysotile: A Manual on Preventive and Control Measures."This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific safety hazard, see .

Standard Specification for Asbestos-Cement Nonpressure Sewer Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2005
实施

1.1 This specification covers nonreinforced concrete pipe with rubber gasket joints to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in Table 1.1.2 This specification is the SI counterpart of Specification C 505.Note 18212;This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation.

Standard Specification for Nonreinforced Concrete Irrigation Pipe With Rubber Gasket Joints [Metric]

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

1.1 This specification covers porous nonreinforced concrete pipe for use in underdrains.1.2 This specification is the metric counterpart of Specification C 654.

Standard Specification for Porous Concrete Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

1.1 This specification covers reinforced concrete pipe designed for specific D-loads and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 A complete metric companion to Specification C 655 has been developed-Specification C 655M; therefore, no metric equivalents are presented in this specification. Note 18212;Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.

Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

1.1 This specification covers reinforced concrete pipe designed for specific D-loads and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 A complete metric companion to Specification C 655 has been developed-Specification C 655M; therefore, no metric equivalents are presented in this specification. Note 18212;Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.

Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

1.1 This specification covers nonreinforced concrete pipe designed for specified strengths and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 This specification is the metric counterpart of Specification C985. Note 18212;This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load conditions and the designated strength of the pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the concrete pipe specified herein is cautioned that he must correlate the field requirements with the pipe strength specified and provide inspection at the construction site.

Standard Specification for Nonreinforced Concrete Specified Strength Culvert, Storm Drain, and Sewer Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q81
发布
2004
实施

1.1 This specification covers single-cell precast reinforced concrete box sections intended to be used for the construction of culverts and for the conveyance of storm water industrial wastes and sewage.1.2 This specification is the companion to inch-pound Specification C 1433.Note 18212;This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends upon the proper selection of the box section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete box sections specified herein is cautioned that he must properly correlate the loading conditions and the field requirements with the box section specified and provide for inspection at the construction site.

Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

1.1 This specification covers single-cell precast reinforced concrete box sections intended to be used for the construction of culverts and for the conveyance of storm water industrial wastes and sewage.1.2 This specification is the companion to inch-pound Specification C 1433.Note 18212;This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends upon the proper selection of the box section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete box sections specified herein is cautioned that he must properly correlate the loading conditions and the field requirements with the box section specified and provide for inspection at the construction site.

Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

Meaning and Suitability8212;The tests called for herein, from their results, indicate the suitability and acceptability of vitrified clay pipe for specifications acceptance, design purposes, regulatory statutes, manufacturing control, and research.1.1 These test methods cover the equipment for, and the techniques of, testing vitrified clay pipe prior to installation. Tests using whole pipe determines the resistance to crushing and hydrostatic forces. Tests using pipe fragments measure the amount of water absorption of the pipe body and the quantity of acid-soluble material that may be extracted from it. Note 18212;The following standards also apply to clay pipe and can be referenced for further information: Practice C 12 and Test Method C 828; Specifications C 425 and C 700. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Vitrified Clay Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q31
发布
2004
实施

1.1 This specification covers single-cell precast conventionally reinforced concrete three-sided structures intended to be used for the construction of culverts and for the conveyance of storm water.1.2 This specification is the metric counterpart of Specification C 1504; therefore, no imperial equivalents are presented in this specification.Note 18212;This specification is primarily a manufacturing and purchasing specification. The successful performance of this product depends upon the proper selection of the geometric section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete three-sided structure specified herein is cautioned that he must properly correlate the loading conditions and the field requirements with the geometric section specified and provide for inspection at the construction site.

Standard Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
发布
2004
实施

1.1 This specification covers reinforced concrete pipe designed for specific D-loads and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 This specification is the metric counterpart of Specification C 655. Note 18212;Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.

Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

1.1 These test methods cover testing of concrete pipe, manhole sections, and tile. The test methods described are used in production testing and acceptance testing to evaluate the properties provided for in the specifications.1.2 The test methods appear in the following order:SectionExternal Load Crushing Strength4Flat Slab Top5Core Strength6Absorption7Hydrostatic8Permeability9Manhole Step10Cylinder Strength111.3 The test specimens shall not have been exposed to a temperature below 40176;F for the 24 h immediately preceding the test.1.4 If any test specimen fails because of mechanical reasons such as failure of testing equipment or improper specimen preparation, it shall be discarded and another specimen taken.1.5 Specimens shall be selected in accordance with the specifications for the type of pipe or tile being tested.1.6 A complete metric companion to Test Methods C 497 has been developed8212;C 497M; therefore, no metric equivalents are presented in these methods.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Concrete Pipe, Manhole Sections, or Tile

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

1.1 This specification covers non-asbestos fiber-cement perforated and plain pipe intended for use in the conveyance of drainage water for the subsurface drainage of highways, airports, farms, foundations, and other similar drainage work. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Non-Asbestos Fiber-Cement Underdrain Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

Meaning and Suitability8212;The tests called for herein, from their results, indicate the suitability and acceptability of vitrified clay pipe for specifications acceptance, design purposes, regulatory statutes, manufacturing control, and research.1.1 These test methods cover the equipment for, and the techniques of, testing vitrified clay pipe prior to installation. Tests using whole pipe determines the resistance to crushing and hydrostatic forces. Tests using pipe fragments measure the amount of water absorption of the pipe body and the quantity of acid-soluble material that may be extracted from it.1.2 The values stated in inch-pound units are to be regarded as the standard. The values stated in parentheses are for information only.1.3 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note 18212;The following standards also apply to clay pipe and can be referenced for further information: Practice C 12 and Test Method C 828; Specifications C 425 and C 700.

Standard Test Methods for Vitrified Clay Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q31
发布
2004
实施

1.1 This specification covers non-asbestos fiber-cement perforated and plain pipe intended for use in the conveyance of drainage water for the subsurface drainage of highways, airports, farms, foundations, and other similar drainage work.1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Non-Asbestos Fiber-Cement Underdrain Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
发布
2004
实施

1.1 This specification covers reinforced concrete pipe designed for specific D-loads and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 This specification is the metric counterpart of Specification C 655. Note 18212;Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.

Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

1.1 These test methods cover testing of concrete pipe, manhole sections, and tile. The test methods described are used in production testing and acceptance testing to evaluate the properties provided for in the specifications.1.2 The test methods appear in the following order:SectionExternal Load Crushing Strength4Flat Slab Top5Core Strength6Absorption7Hydrostatic8Permeability9Manhole Step10Cylinder Strength111.3 The test specimens shall not have been exposed to a temperature below 4176;C for the 24 h immediately preceding the test.1.4 If any test specimen fails because of mechanical reasons such as failure of testing equipment or improper specimen preparation, it shall be discarded and another specimen taken.1.5 Specimens shall be selected in accordance with the specifications for the type of pipe or tile being tested.1.6 These methods are the metric companion of Test Methods C 497.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Concrete Pipe, Manhole Sections, or Tile [Metric]

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

1.1 This specification covers reinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts.1.2 A complete metric companion to Specification C 76 has been developed8212;C 76M; therefore, no metric equivalents are presented in this specification.Note 18212;This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.Note 28212;Attention is called to the specification for reinforced concrete D-load culvert, storm drain, and sewer pipe (Specification C 655).

Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
发布
2004
实施

1.1 This specification covers nonreinforced concrete pipe designed for specified strengths and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts.1.2 A complete companion to Specification C 985 has been developed, C 985M; therefore, no metric equivalents are presented in this specification. Note 1This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load conditions and the designated strength of the pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the concrete pipe specified herein is cautioned that he must correlate the field requirements with the pipe strength specified and provide inspection at the construction site.

Standard Specification for Nonreinforced Concrete Specified Strength Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved