1.1 This specification covers the manufacture and acceptance of precast concrete pipe designed to conform to the owner''s design requirements and to ASCE 15-93 or an equivalent design specification.1.2 This specification is the companion to SI Specification C 1417M; therefore, no SI equivalents are presented in this specification.

Standard Specification for Manufacture of Reinforced Concrete Sewer, Storm Drain, and Culvert Pipe for Direct Design

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

1.1 This specification establishes the criteria for the manufacture, quality assurance testing, inspection, installation, field acceptance testing, and product marking of vitrified clay pipe to be used in microtunneling, sliplining, pipe bursting, in casings, and in tunnels for the conveyance of sewage, industrial wastes, and storm water.1.1.1 Sections 3 through 7 and 9 of this specification contain manufacturing, quality assurance testing, inspection, and product marking criteria which are applicable to vitrified clay pipe prior to installation.1.1.2 Section 8 of this specification contains criteria for the installation and field acceptance testing of vitrified clay pipe.1.2 This specification also covers materials and test requirements for jointing of the pipe.1.3 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Vitrified Clay Pipe and Joints for Use in Microtunneling, Sliplining, Pipe Bursting, and Tunnels

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
发布
2004
实施

1.1 This specification covers nonreinforced concrete pipe designed for specified strengths and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts.1.2 A complete companion to Specification C 985 has been developed, C 985M; therefore, no metric equivalents are presented in this specification. Note 1This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load conditions and the designated strength of the pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the concrete pipe specified herein is cautioned that he must correlate the field requirements with the pipe strength specified and provide inspection at the construction site.

Standard Specification for Nonreinforced Concrete Specified Strength Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

p>1.1 This specification covers concrete drain tile with internal diameters from 100 to 900 mm, that are intended to be used for surface and subsurface drainage.1.2 This specification is the metric counterpart of Specification C 412.Note 18212;This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of drain tile. However, experience has shown that the successful performance of the product depends upon the proper selection of the class of drain tile, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of drain tile specified and provide for or require inspection at the construction site.

Standard Specification for Concrete Drain Tile (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

1.1 This specification covers nonreinforced concrete pipe designed for specified strengths and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts.1.2 This specification is the metric counterpart of Specification C 985. Note 1This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load conditions and the designated strength of the pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the concrete pipe specified herein is cautioned that he must correlate the field requirements with the pipe strength specified and provide inspection at the construction site.

Standard Specification for Nonreinforced Concrete Specified Strength Culvert, Storm Drain, and Sewer Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

1.1 This specification covers single-cell precast conventionally reinforced concrete three-sided structures intended to be used for the construction of culverts and for the conveyance of storm water.1.2 A complete metric companion to Specification C 1504 has been developed8212;C 1504M; therefore, no metric equivalents are presented in this specification.Note 18212;This specification is primarily a manufacturing and purchasing specification. The successful performance of this product depends upon the proper selection of the geometric section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete three-sided structure specified herein is cautioned that he must properly correlate the loading conditions and the field requirements with the geometric section specified and provide for inspection at the construction site.

Standard Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
发布
2004
实施

1.1 This specification covers nonreinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts.1.2 This specification is the metric counterpart of Specification C 14.Note 18212;This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of pipe specified and provide for or require inspection at the construction site.

Standard Specification for Concrete Sewer, Storm Drain, and Culvert Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

1.1 This specification covers nonreinforced concrete pipe designed for specified strengths and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 A complete companion to Specification C985 has been developed, C985M; therefore, no metric equivalents are presented in this specification. Note 18212;This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load conditions and the designated strength of the pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the concrete pipe specified herein is cautioned that he must correlate the field requirements with the pipe strength specified and provide inspection at the construction site.

Standard Specification for Nonreinforced Concrete Specified Strength Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q81
发布
2004
实施

1.1 This specification covers nonreinforced concrete pipe designed for specified strengths and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts.1.2 This specification is the metric counterpart of Specification C 985. Note 1This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load conditions and the designated strength of the pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the concrete pipe specified herein is cautioned that he must correlate the field requirements with the pipe strength specified and provide inspection at the construction site.

Standard Specification for Nonreinforced Concrete Specified Strength Culvert, Storm Drain, and Sewer Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2004
实施

1.1 This specification covers perforated concrete pipe intended to be used for underdrainage. 1.2 This specification is the SI companion to Specification C 444. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Perforated Concrete Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2003
实施

1.1 This specification covers nonreinforced concrete pipe with rubber gasket joints to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in Table 1.1.2 This specification is the SI counterpart of Specification C 505. Note 18212;This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation.

Standard Specification for Nonreinforced Concrete Irrigation Pipe With Rubber Gasket Joints [Metric]

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2003
实施

1.1 This specification covers porous nonreinforced concrete pipe for use in underdrains.1.2 This specification is the metric counterpart of Specification C 654.

Standard Specification for Porous Concrete Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2003
实施

1.1 This specification covers nonreinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts.1.2 A complete metric companion to Specification C 14 has been developed8212;C 14M; therefore, no metric equivalents are presented in this specification. Note 18212;This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load conditions and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of pipe specified and provide for or require inspection at the construction site.

Standard Specification for Concrete Sewer, Storm Drain, and Culvert Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2003
实施

1.1 This specification covers the minimum material requirements and describes the procedures for installing concrete pavements and linings in corrugated steel pipes and structural plate structures in the field. Specific designs with additional or greater requirements shall be detailed in the contract documents. This specificaiton is applicable to paving or lining new pipes and for rehabilitating existing structures. The pipe to be paved or lined is described in Specifications A 760/A 760M, A 761/A 761M, and A 762/A 762M. 1.2 This specification covers pipes 48 in. (1 200 mm) and larger for pavements and 24 in. (600 mm) and larger for full linings. 1.3 New pipes are to be designed in accordance with Practice A 796 and installed in accordance with Practice A 798 for factory-made pipes and Practice A 807 for structural plate structures. Structures to be rehabilitated shall be structurally stable. 1.4 Pipes with plant installed concrete pavements and linings are covered under Specification A 849. 1.5 This specification is applicable to product in either inch/pound units as A 979 or in SI units as A 979M. Inch/pound units and SI units are not necessarily equivalent. SI units are shown in brackets in the text for clarity, but they are the applicable values when materials are orderd to A 979M. 1.6 This standard may involve hazardous materials, operations and equipment. The standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Concrete Pavements and Linings Installed in Corrugated Steel Structures in the Field

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
发布
2003
实施

1.1 This specification covers perforated concrete pipe intended to be used for underdrainage.1.2 This specification is the metric counterpart of Specification C 444.

Standard Specification for Perforated Concrete Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2003
实施

1.1 This specification covers concrete drain tile with internal diameters from 4 to 36 in. that are intended to be used for surface and subsurface drainage.1.2 A complete metric companion to Specification C 412 has been develop8212;-C 412M; therefore, no metric equivalents are presented in this specification. Note 18212;This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of drain tile. However, experience has shown that the successful performance of the product depends upon the proper selection of the class of drain tile, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of drain tile specified and provide for or require inspection at the construction site.

Standard Specification for Concrete Drain Tile

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2003
实施

1.1 This specification covers nonreinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts.1.2 This specification is the metric counterpart of Specification C 14. Note 18212;This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of pipe specified and provide for or require inspection at the construction site.

Standard Specification for Concrete Sewer, Storm Drain, and Culvert Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2003
实施

1.1 This practice covers procedures for testing the joints of installed precast concrete pipe sewer lines, when using either air or water under low pressure to demonstrate the integrity of the joint and the construction procedures. This practice is used for testing 675-mm and larger diameter precast concrete sewer lines utilizing rubber gasket sealed joints.1.2 This practice is the metric companion of Practice C 1103. Note 18212;The owner shall specify the following: who will conduct, observe, and furnish labor, material, and measuring devices and pay for the tests; who is responsible for determining local ground conditions; and whether an air or water test is to be used.Note 28212;The user of this practice is advised that test criteria presented in this practice are similar to those in general use. Pipe 600-mm diameter and smaller shall be accepted by infiltration or exfiltration testing utilizing Practice C 969M or by low pressure air testing utilizing Practice C 924M. Pipe greater than 600-mm diameter shall be accepted by infiltration or exfiltration testing utilizing C 969M.Note 38212;The user is advised that no correlation has been found between air loss and water leakage.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific safety precautions are given in Section 6.

Standard Practice for Joint Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2003
实施

1.1 This specification covers nonreinforced concrete pipe with rubber gasket joints to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in .1.2 A complete metric companion to Specification C 505 has been developed8212;C 505M; therefore, no SI equivalents are presented in this specification. Note 18212;This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation.

Standard Specification for Nonreinforced Concrete Irrigation Pipe With Rubber Gasket Joints

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2003
实施

1.1 This specification covers porous nonreinforced concrete pipe for use in underdrains. 1.2 A complete metric companion to this specification has been developed8212;C654M; therefore, no metric equivalents are presented in this specification.

Standard Specification for Porous Concrete Pipe