23.060.10 球阀 标准查询与下载



共找到 232 条与 球阀 相关的标准,共 16

The document applies to water valves with nominal pressure 40 bar as used in mining as borrow pit for water for fire and dust suppression.

Watervalve, nominal pressure 40 - Dimensions and requirements

ICS
23.060.10
CCS
J16
发布
2001-08
实施

These requirements cover automatic drain valves that are intended to drain water from cavities in standpipe systems intended usually to be empty, such as those between a hose valve and hose rack, pipe sections between fire department connections and check valves, and the like. The valves covered by these requirements are intended for installation and use in accordance with the standards for the Installation of Sprinkler Systems, ANSI/NFPA 13, and Standpipe and Hose Systems, ANSI/NFPA 14.

UL Standard for Safety Automatic Drain Valves for Standpipe Systems Third Edition

ICS
23.060.10
CCS
J16
发布
2001-04-18
实施

Electrically operated valves

7/23/2001 (101p)

ICS
23.060.10
CCS
发布
2001-01-01
实施

The document specifies the fitness for purpose and certification requirements for float type air valves and purgers having nominal pressures of PN 6, PN 10, PN 16, PN 25 and all diamters as specified in prEN 1074-1 but limited to a maximum of DN 300.#,,#

Valves for water supply - Fitness for purpose requirements and appropriate verification tests - Part 4: Air valves; German version EN 1074-4:2000

ICS
23.060.10
CCS
J16
发布
2000-10
实施

This European Standard specifies the minimum fitness for purpose requirements for valves to be used in, or connected to, water supply pipe systems above or below ground (see EN 805), carrying water intended for human consumption. This standard specifies the design requirements, the performance requirements, and the conformity assessment method for valves, whatever their type and materials. This standard applies in priority to any other product or test standard: the requirements from other standards apply only when this standard refers to them. This standard deals with the requirements applicable to air valves with DN up to DN 300 and PFA 6 to PFA 25.

Valves for water supply - Fitness for purpose requirements and appropriate verification tests - Air valves

ICS
23.060.10
CCS
J16
发布
2000-09-15
实施
2000-09-15

The document specifies the fitness for purpose and certification requirements for float type air valves and purgers having nominal pressures of PN 6, PN 10, PN 16, PN 25 and all diamters as specified in prEN 1074-1 but limited to a maximum of DN 300

Valves for water supply - Fitness for purpose requirements and appropriate verification tests - Part 4: Air valves

ICS
23.060.10
CCS
发布
2000-07-01
实施

The purpose of this standard EN 1213 is to specify: - the requirements for the materials and the design of stopvalves; - the mechanical, hydraulic and acoustic requirements; - the test methods; - the marking requirements; for copper alloy stopvalves for use with drinking water supply in buildings. This standard applies primarily to copper alloy stopvalves, dimensions DN 10 to DN 100, for potable water supply in buildings up to PN 10 and a distribution temperature of 65 ℃. Occasional excursions up to 95 ℃ are permitted for a period of 1 h maximum. Other metallic materials can be used if it can be verified that they are suitable for the application. This standard applies also to stopvalves in combination with accessories in the same body. This standard does not apply to regulating or servicing valves, designed specially to isolate sanitary tapware or other sanitary appliances.

Building valves - Copper alloy stopvalves for potable water supply in buildings - Tests and requirements

ICS
23.060.10
CCS
J16
发布
2000-02-15
实施
2000-02-15

Electrically operated valves

11/27/2000 (2p)

ICS
23.060.10
CCS
发布
2000-01-01
实施

This Standard covers face-to-face and end-to-end dimensions of straightway valves, and center-to-face and center-to-end dimensions of angle valves. Its purpose is to assure installation interchangeability for valves of a given material, type, size, rating class, and end connection.

Face-to-Face and End-to-End Dimensions of Valves

ICS
23.060.10
CCS
J16
发布
2000
实施

This document specifies the characteristics of the materials and the design, the mechanical, hydraulic and acoustic requirements and the test method for copper alloy stop valves, dimensions DN 10 to DN 80 for potable water supply in buildings up to PN 10 and a distribution temperature of 65 ?#,,#

Building valves - Copper alloy stopvalves for potable water supply in buildings - Tests and requirements; German version EN 1213:1999

ICS
23.060.10
CCS
J16
发布
1999-12
实施

This International Standard specifies the requirements for bolted bonnet steel globe valves for general-purpose applications and having the following features: — bolted bonnets; — flanged, threaded, socket-welding (DN 65 and smaller) or butt-welding ends; — outside screw and yoke, inside screw and rising stem; — with metallic or soft obturator (disc, piston) or seat seals. It covers valves of the following nominal sizes, DN: — 10; 15; 20; 25; 32; 40; 50; 65; 80; 100; 125; 150; 200; 250; 300; 350; 400; and applies to valves of the following nominal pressures, PN: — 10; 16; 20; 25; 40; 50; 110.

Bolted bonnet steel globe valves for general-purpose applications

ICS
23.060.10
CCS
J16
发布
1999-09
实施

These requirements cover electrically operated general purpose and safety valves rated 600 volts or less and intended for the control of fluids, such as air, gases, oils, refrigerants, steam, water, and the like. Electrically operated valves, other than automotive fuel valves, covered by these requirements are intended to be used in other than hazardous locations as defined by the National Electrical Code, NFPA 70. These requirements also cover electrically operated valves intended to be factory installed on or in certain appliances as operating or safety controls. These requirements do not cover general purpose valves that are not intended to be used with a flammable or hazardous fluid and are intended only for connection to a low voltage circuit of limited power supplied by a primary battery or a separate external Class 2 transformer. However, if a high-voltage transformer with a low-voltage secondary is incorporated as an integral part of a valve, the assembly is covered by these requirements. These requirements do not cover valves for use in hydraulic fluid power systems. These requirements do not cover valves covered by the requirements in the Standard for Automatic Valves for Gas Appliances, IAS/AGA Z21.21.

Electrically operated valves

ICS
23.060.10
CCS
J16
发布
1999-03-23
实施

Details test and examination criteria for: 1.Temperature relief valves and combination temperature and pressure relief valves for use on storage tanks of hot water supply systems without heater input limitation; 2.Valves having only pressure relief featu

Relief Valves for Hot Water Supply Systems (same as CSA 4.4-1998)

ICS
23.060.10
CCS
Q83
发布
1999
实施

This specification covers the design, construction, testing, and operating requirements for pneumatic-operated, globe-style, control valves complete with actuators for various fluid systems (steam, gas, and liquid applications). The control valves with actuators may be procured under this specification complete with all associated pneumatic instrumentation necessary for the valve to function in the system application; however, complete and detailed requirements for air instrumentation are beyond the scope of this specification and thus are not included here. This specification is not intended to cover quarter-turn or multi-turn stem valves. The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

Specification for Pneumatic-Operated, Globe-Style, Control Valves

ICS
23.060.10
CCS
J16
发布
1999
实施

本标准适用于标称使用压力为 10kgf∕cm2 之青铜螺纹型球阀(以下简称阀),其适于流体之状态与最使用压力之关系如表 1 所示。注:本标准中,{ } 内之值为国际单位(SI),并记供参考。

Bronze Screwed Ball Valves (10 kgf/c㎡)

ICS
23.060.10
CCS
发布
1998-12-29
实施
1998-12-29

Interpretations to B16.34-1996 Valves - Flanged, Threaded, and Welding End Includes Interpretation No. 2

Interpretations to B16.34-1996 Valves - Flanged, Threaded, and Welding End (Includes Interpretation No. 2)

ICS
23.060.10
CCS
J16
发布
1998-07-01
实施

Hand-operated shut-off valves for welding, cutting and allied processes - Type of construction, safety requirements, tests

ICS
23.060.10
CCS
J33
发布
1998-07
实施
1998-07-01

Valves - Flanged, threaded, and welding end; Addenda

ICS
23.060.10
CCS
J16
发布
1998
实施

This International Standard specifies the constructive and qualitative criteria, test methods and marking for valves having a polyethylene (PE) body and intended for use with PE pipes and fittings for the supply of gaseous fuels. In addition, it specifies some general properties of the material from which these valves are made. It is applicable to bi-directional valves with spigot ends or electrofusion sockets conforming to ISO 8085-3 intended to be used with pipes conforming to ISO 4437 and with spigot fittings conforming to ISO 8085-2. This International Standard covers valves having a nominal outside diameter up to and including 225 mm and for which the service temperature lies between -20 ℃ and +40 ℃. Methods of test are given in normative annexes A to F inclusive.

Polyethylene (PE) valves for gas distribution systems

ICS
23.060.10
CCS
G33
发布
1997-12
实施

This specification covers the design, construction, testing, and operating requirements for hand operated, quick-change cartridge trim, in-line body and angle-body, globe style valves for use in gas (except oxygen gas), and hydraulic systems. These valves may be used for on-off, and/or throttling applications. The values stated in this specification in inch-pounds units are to be regarded as the standard. The SI equivalent shown in parenthesis are provided for information only.

Specification for Hand-Operated Globe-Style Valves for Gas (Except Oxygen Gas) and Hydraulic Systems

ICS
23.060.10
CCS
J16
发布
1997
实施