Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan ) and d.c. resistivity (IEC 60247:2004); German version EN 60247:2004

ICS
29.040.10
CCS
K15
发布
2005-01
实施
2005-01-01

During this test, insulating oil in an evacuated cell is subjected to a high voltage discharge between two electrodes. The discharge generates free electrons. These electrons collide with the oil molecules causing many of them to become electronically excited. Some of these molecules lose this energy as a quanta of light emitting fluorescent radiation. Some of the other excited molecules decompose into gases, ionized molecules and free radicals. These changes can provide an indication of the stability of oils under the conditions of this test method. The measures of these changes are the increase of the pressure in the test cell and the increase in the dissipation factor of the test specimen. During the test, the gas content increases in the cell and the concentration of charge carriers increases in the oil.1.1 This test method covers a laboratory technique that measures the stability of new, used, or reclaimed insulating oils, similar to those described in Specification D 3487 in the presence of a controlled electric discharge. When subjected to this type of discharge, insulating oils absorb energy and produce gases as well as ionized molecules (charge carriers). The quantity of these decay products can be measured and can provide an indication of the stability of oils under the conditions of this test.1.2 The gases are retained in the discharge cell and their pressure measured. The charge carriers remain in the test specimen. The change in the dissipation factor before and after the discharge is determined.1.3 The values stated in SI units are to be regarded as the standard. The values stated in parentheses are for information only.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific cautionary statements are given in and .

Standard Test Method for Stability of Insulating Oils of Petroleum Origin Under Electrical Discharge

ICS
29.040.10
CCS
E38
发布
2005
实施

Unused hydrocarbon-based insulating liquids - Test methods for evaluating the oxidation stability.

ICS
29.040.10
CCS
K15
发布
2004-09-01
实施
2004-09-20

This European Standard describes three test methods using the same apparatus for evaluating the oxidation stability of mineral insulating oils and of hydrocarbon-based insulating liquids.

Unused hydrocarbon-based insulating liquids - Test methods for evaluating the oxidation stability

ICS
29.040.10
CCS
发布
2004-08-13
实施
2004-07-06

Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear.

ICS
29.040.10
CCS
K15
发布
2004-08-01
实施
2004-08-20

This part of IEC 62021 describes the procedure for the determination of the acidity of unused and used electrical mineral insulating oils. The method may be used to indicate relative changes that occur in a mineral insulatin oil during use under oxidizing conditions regardless of the colour or other properties of the resulting mineral oil. The acidity can be used in the quality control of unused mineral oil. As a varity of oxidation products present in used mineral oil contribute to acidity and these products vary widely in their corrosion properties, the test cannot be used to predict corrosiveness of a mineral oil under service conditions.

Insulating liquids - Determination of acidity - Part 1: Automatic potentiometric titration

ICS
29.040.10
CCS
发布
2004-07-07
实施
2004-06-09

Insulating liquids - Determination of acidity - Part 1: Automatic potentiometric titration (IEC 62021-1:2003); German version EN 62021-1:2003

ICS
29.040.10
CCS
E38
发布
2004-06
实施
2004-06-01

This International standard describes methods for the determination of the dielectric dissipation factor (tan δ), relative permittivity and d.c. resistivity of any insulating liquid material at the test temperature. The methods are primarily intended for making reference tests on unused liquids. They can also be applied to liquids in service in transformers, cables and other electrical apparatus. However the method is applicable to a single phase liquid only. When it is desired to make routine determinations, simplified procedures, as described in Annex C, may be adopted. With insulating liquids other than hydrocarbons, alternative cleaning procedures may be required.

Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan ) and d.c. resistivity

ICS
29.040.10
CCS
K15
发布
2004-04-26
实施
2004-04-26

This is Amendment 1 to IEC 61125-1992 (Unused hydrocarbon-based insulating liquids - Test methods for evaluating the oxidation stability)

Unused hydrocarbon-based insulating liquids - Test methods for evaluating the oxidation stability; Amendment 1

ICS
29.040.10
CCS
E38
发布
2004-04
实施
2018-01-17

本标准规定了在试验温度卜液体绝缘材料的介质损耗因数、相对电容率和直流电阻率的测量方法。 本标准主要是对未使川过的液体做参考性试验,但也适用于在运行中的变压器、电缆和其他电工设 备中的液体。然而,本标准只适用于单相液体,当做例行测量时可以采用简化方法和附录C所述的 方法。 对于非碳氢化合物绝缘液体,则要求采用其他清洗方法。

Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan ) and d.c. resistivity

ICS
29.040.10
CCS
K15
发布
2004-02
实施

Testing methodology for wipers used in electrical insulating oil

ICS
29.040.10
CCS
发布
2003-12-28
实施
2003-12-28

This part of IEC 62021 describes the procedure for the determination of the acidity of unused and used electrical mineral insulating oils. NOTE 1 In unused and used mineral insulating oils, the constituents that may be considered to have acidic characteristics include organic acids, phenolic compounds, some oxidation products, resins, organometallic salts and additives. The method may be used to indicate relative changes that occur in a mineral insulating oil during use under oxidizing conditions regardless of the colour or other properties of the resulting mineral oil. The acidity can be used in the quality control of unused mineral oil. As a variety of oxidation products present in used mineral oil contribute to acidity and these products vary widely in their corrosion properties, the test cannot be used to predict corrosiveness of a mineral oil under service conditions. NOTE 2 The acidity results obtained by this test method may or may not be numerically the same as those obtained by colorimetric methods, but they are generally of the same magnitude.

Insulating liquids - Determination of acidity - Automatic potentiometric titration

ICS
29.040.10
CCS
K15
发布
2003-12-23
实施
2003-12-23

Covers specifications and test methods for unused mineral insulating oils. It applies to oil delivered to the agreed point and time of delivery, intended for use in transformers, switchgear and similar electrical equipment in which oil is required as an

Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear

ICS
29.040.10
CCS
E38
发布
2003-11
实施
2012-02-21

Petroleum products-Electrical insulating oils-Detection of corrosive sulfur

ICS
29.040.10
CCS
发布
2003-09-06
实施

Describes the procedure for the determination of the acidity of unused and used electrical mineral insulating oils. The method may be used to indicate relative changes that occur in a mineral insulating oil during use under oxidizing conditions regardles

Insulating liquids - Determination of acidity - Part 1: Automatic potentiometric titration

ICS
29.040.10
CCS
E38
发布
2003-06
实施
2003-06-25

Sediment in insulating oil may deposit on transformer parts and interfere with heat transfer and may choke oil ducts; thus hindering oil circulation and heat dissipation. Inorganic sediment usually indicates contamination of some type and organic sediment indicates either deterioration of the oil or contamination. Soluble sludge indicates deterioration of the oil, presence of contaminants, or both. It serves as a warning that formation of sediment may be imminent. The determination of sediment and soluble sludge in a used insulating oil assists in deciding whether the oil may continue to be used in its existing condition or should be replaced, reclaimed, or reconditioned.1.1 This test method covers the determination of sediment and soluble sludge in service-aged insulating oils of petroleum origin. Also, provision is made for determining organic and inorganic content of the sediment. The method is intended primarily for oils of comparatively low viscosity; for example 5.7 to 13.0 cSt (mm2/s) at 40°C (104°F). Suitability for high viscosity oils have not been determined. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Sediments and Soluble Sludge in Service-Aged Insulating Oils

ICS
29.040.10
CCS
E38
发布
2003
实施

This test method uses a ratio turbidimetric optical system to measure the turbidity of insulating oils relative to turbidity standards. Cloudiness or turbidity is attributed to matter whose diameter is approximately 20 % of the wavelength of the incident light. Increasing turbidity signifies increasing transformer fluid contamination, either from external sources or internal chemical reactions (such as oxidation) that produce fine particulate matter. Other turbidity sources, such as water droplets or gas bubbles, are not of interest in this evaluation of insulating oils. The elimination of these interferences is described in 6.2 and 6.6. This test method quantifies changes which may not be apparent to the unaided human eye.1.1 This test method covers the laboratory procedure that ascertains the quantity of suspensions in insulating oils of petroleum origin using a nephelometric measurement technique to determine the fluid''s turbidity. This test method is designed to reveal changes that may occur to these oils.1.2 This test method is applicable for turbidities in the range of 0.1 to 500 Nephelometric Turbidity Units (NTU).1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Measurement of Turbidity in Mineral Insulating Oil of Petroleum Origin

ICS
29.040.10
CCS
E38
发布
2003
实施

SOFT MAGNETIC IRON BARS

ICS
29.040.10
CCS
发布
20021130
实施
20021130

SOFT MAGNETIC IRON PLATES

ICS
29.040.10
CCS
发布
20021130
实施
20021130

MAGNETIC IRON OXIDE POWDER

ICS
29.040.10
CCS
发布
2002-11-30
实施