Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria (IEC 61952:2008); German version EN 61952:2008

ICS
29.080.10
CCS
K48
发布
2009-06
实施
2009-06-01

Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1000 V - Definitions, test methods and acceptance criteria (IEC 61109:2008); German version EN 61109:2008

ICS
29.080.10
CCS
K48
发布
2009-06
实施
2009-06-01

Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1000 V. Definitions, test methods and acceptance criteria

ICS
29.080.10
CCS
发布
2009-03-31
实施
2009-03-31

This International Standard applies to composite suspension/tension insulators consisting of a load-bearing cylindrical insulating solid core consisting of fibres – usually glass – in a resinbased matrix, a housing (outside the insulating core) made of polymeric material and end fittings permanently attached to the insulating core. Composite insulators covered by this standard are intended for use as suspension/tension line insulators, but it should be noted that these insulators can occasionally be subjected to compression or bending, for example when used as phase-spacers. This standard can be applied in part to hybrid composite insulators where the core is made of a homogeneous material (porcelain, resin), see Clause 8. The object of this standard is to – define the terms used, – prescribe test methods, – prescribe acceptance criteria. This standard does not include requirements dealing with the choice of insulators for specific operating conditions.

Insulators for overhead lines — Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V — Definitions, test methods and acceptance criteria

ICS
29.080.10
CCS
K48
发布
2009-03-31
实施
2009-03-31

Applies to insulator strings and sets comprising string insulator units of ceramic material, glass or composite material for use on a.c. overhead lines and traction lines with a nominal voltage above 1 000 V and a frequency between 15 Hz and 100 Hz. Also

Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests

ICS
29.080.10
CCS
K48
发布
2009-02-20
实施

Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria (IEC 61109:2008)

ICS
29.080.10
CCS
发布
2009-01-30
实施
2009-01-30

Guide for test methods and procedures to evaluate the electrical performance of insulators in freezing conditions

ICS
29.080.10
CCS
K48
发布
2009
实施

The guide specifies procedures for testing equipment when external insulation of the test object is subjected to combinations of contamination, ice, snow or cold fog. The methods are applicable only to tests on equipment with a rated voltage above 1 kV.

Guide for Test Methods and Procedures to Evaluate the Electrical Performance of Insulators in Freezing Conditions

ICS
29.080.10
CCS
K48
发布
2009
实施

Insulators of ceramic material or glass for overhead lines with a nominal voltage greater than 1 000 V - Impulse puncture testing in air

ICS
29.080.10
CCS
发布
2009
实施

This International Standard applies to composite suspension/tension insulators consisting of a load-bearing cylindrical insulating solid core consisting of fibres – usually glass – in a resinbased matrix, a housing (outside the insulating core) made of polymeric material and end fittings permanently attached to the insulating core.Composite insulators covered by this standard are intended for use as suspension/tension line insulators, but it should be noted that these insulators can occasionally be subjected to compression or bending, for example when used as phase-spacers.This standard can be applied in part to hybrid composite insulators where the core is

Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria

ICS
29.080.10
CCS
发布
2008-12-01
实施
2008-12-01

IEC 61467:2008 applies to insulator strings and sets comprising string insulator units of ceramic material, glass or composite material for use on a.c. overhead lines and traction lines with a nominal voltage above 1 000 V and a frequency between 15 Hz and 100 Hz. This standard also applies to insulator strings or sets of similar design used in substations. This standard establishes a standard test procedure for power arc tests on insulator sets. It also establishes a standard test procedure for power arc tests on short strings. This standard does not apply to insulator sets mounted on non-metallic poles or towers. This edition cancels and replaces IEC/TR 61467, which was published as a technical report in 1997. It constitutes a technical revision and now has the status of an International Standard.

Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests

ICS
29.080.10
CCS
发布
2008-11-28
实施
2009-02-01 (7)

Applies to ceramic and glass hollow insulators intended for general use in electrical equipment and ceramic hollow insulators intended for use with a permanent gas pressure in switchgear and controlgear.

Characteristics of hollow pressurised and unpressurised ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V

ICS
29.080.10
CCS
K48
发布
2008-09-05
实施

Applies to composite line post insulators consisting of a load-bearing cylindrical insulating solid core consisting of fibres - usually glass - in a resin-based matrix, a housing (outside the insulating core) made of polymeric material and end fittings p

Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria

ICS
29.080.10
CCS
K48
发布
2008-09-05
实施

Applies to composite suspension/tension insulators consisting of a load-bearing cylindrical insulating solid core consisting of fibres - usually glass - in a resin-based matrix, a housing (outside the insulating core) made of polymeric material and end f

Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria

ICS
29.080.10
CCS
K48
发布
2008-09-05
实施

Characteristics of hollow pressurised and unpressurised ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V

ICS
29.080.10
CCS
K48
发布
2008-06-30
实施
2008-06-30

Characteristics of hollow pressurised and unpressurised ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V

ICS
29.080.10
CCS
发布
2008-06-30
实施
2008-06-30

Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1000 V - Definitions, test methods, acceptance criteria and design recommendations (IEC 61462:2007); German version EN 6

ICS
29.080.10
CCS
K48
发布
2008-06
实施
2008-06-01

This Technical Specification applies to - ceramic and glass hollow insulators intended for general use in electrical equipment; - ceramic hollow insulators intended for use with a permanent gas pressure in switchgear and controlgear. They are intended for indoor and outdoor use in electrical equipment, operating on alternating current with a rated voltage greater than 1 000 V and a frequency not greater than 100 Hz or for use in direct current equipment with a rated voltage greater than 1 500 V. This specification specifies the dimensional and mechanical characteristics of the hollow insulator, which are essential for interchangeability of the hollow insulator of the same type. It is not the object of this specification to prescribe electrical characteristics because they are dependent on the apparatus of which the hollow insulator ultimately forms a part. However, standard lightning impulse withstand voltage which is provided in IEC 60071-1 is described only for reference for classification purpose. This specification applies to hollow insulators for use in electrical equipment in clean areas or lightly polluted areas, where seismic qualification is not required. For use in areas characterised by heavy pollution levels and for other particular or extreme environmental conditions such as seismic force, it may be necessary for certain dimensions to be changed. The hollow insulators covered by this specification are: a) straight type hollow insulators with metal fittings on both ends; b) taper type hollow insulators with metal fittings on both ends; c) straight type hollow insulators without metal fittings; d) taper type hollow insulators without metal fittings. The hollow insulators are intended for use in electrical equipment, for example: - circuit-breakers; - instrument transformers; - surge arresters; - bushings; - cable sealing ends; - switch-disconnectors; - disconnectors; - earthing switches; - capacitors. There may be some cases that hollow insulators whose design can strongly be influenced by other components of specific equipment, for example, active parts of circuit-breakers. For such cases, the hollow insulators can be separately designed, depending on respective requirements of such equipment and not be covered by this specification. NOTE 1 Hollow insulators not prescribed in this specification can also be applied to electrical equipment, depending on specific requirements of the equipment. However, if similar insulators are available in this specification, it is preferable to apply them. NOTE 2 For general recommendations for design and tests of the hollow insulators, see IEC 62155 NOTE 3 For characteristics of hollow insulators for use in polluted areas, reference can be made to IEC 60815- 1and IEC 60815-2.

Characteristics of hollow pressurised and unpressurised ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V

ICS
29.080.10
CCS
K48
发布
2008-05
实施

This International Standard applies to composite line post insulators consisting of a load- bearing cylindrical insulating solid core consisting of fibres - usually glass - in a resin-based matrix, a housing (outside the insulating core) made of polymeric material and end fittings permanently attached to the insulating core. Composite line post insulators covered by this standard are subjected to cantilever, tensile and compressive loads, when supporting the line conductors. They are intended for use on a.c. overhead lines with a rated voltage greater than 1 000 V and a frequency not greater than 100 Hz. The object of this standard is - to define the terms used, - to prescribe test methods, - to prescribe acceptance or failure criteria. This standard does not include requirements dealing with the choice of insulators for specific operating conditions.

Insulators for overhead lines - Composite line post insulators for a.c. systems with a nominal voltage greater than 1000 V - Definitions, test methods and acceptance criteria

ICS
29.080.10
CCS
K48
发布
2008-05
实施
2008-06-03

This International Standard applies to composite suspension/tension insulators consisting of a load-bearing cylindrical insulating solid core consisting of fibres - usually glass - in a resin- based matrix, a housing (outside the insulating core) made of polymeric material and end fittings permanently attached to the insulating core. Composite insulators covered by this standard are intended for use as suspension/tension line insulators, but it should be noted that these insulators can occasionally be subjected to compression or bending, for example when used as phase-spacers. This standard can be applied in part to hybrid composite insulators where the core is made of a homogeneous material (porcelain, resin), see Clause 8. The object of this standard is to - define the terms used, - prescribe test methods, - prescribe acceptance criteria. This standard does not include requirements dealing with the choice of insulators for specific operating conditions.

Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1000 V - Definitions, test methods and acceptance criteria

ICS
29.080.10
CCS
K48
发布
2008-05
实施
2008-05-31