29.120.20 连接装置 标准查询与下载



共找到 913 条与 连接装置 相关的标准,共 61

UL Standard for Safety Metallic Outlet Boxes (Eleventh Edition; Reprint with Revisions Through and Including August 11@ 2017)

ICS
29.120.20
CCS
K36
发布
2017-8-14
实施
0000-00-00

This document sets the general and dimensional interchangeability requirements for plugs, socket-outlets, connectors and appliance inlets with arcuate contacts of standardized configurations (hereinafter referred to as accessories), with a rated operating voltage not exceeding 600 V AC at a frequency of 50 Hz and 60 Hz and with rated currents of 20 A and 30 A, primarily intended for commercial use indoors, in conditions where the presence of water is negligible. This document applies to accessories for use when the ambient temperature is normally within the range of -25 °C to +40 °C. These accessories are intended to be connected to cables of copper or copper alloy only. Interchangeability requirements are defined for IP20 accessories. NOTE The conditions of use indoors are based on the limitations given by IEC 60364-5-51:2005, Table 51A, AD1. Socket-outlets or appliance inlets incorporated in or fixed to electrical equipment are within the scope of this document.

Plugs, socket-outlets and couplers with arcuate contacts

ICS
29.120.20
CCS
发布
2017-09-00
实施
2017-09-30

Cable cleats for electrical installations

ICS
29.120.20
CCS
K13
发布
2016-05-06
实施
2016-05-06

Cable cleats for electrical installations

ICS
29.120.20
CCS
K13
发布
2016-03-31
实施
2016-03-31

Glands for electrical cables - Cables screw bushings

ICS
29.120.20
CCS
K15
发布
2016-03
实施

IEC 61914:2015 is available as IEC 61914:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61914:2015 specifies requirements and tests for cable cleats and intermediate restraints used for securing cable in electrical installations. Cable cleats provide resistance to electromechanical forces where declared. This standard includes cable cleats that rely on a mounting surface specified by the manufacturer for axial and/or lateral retention of cables. This second edition cancels and replaces the first edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Additional declaration and test for lateral load retention depending on cleat mounting orientation with associated new figures; b) Additional declaration of the distance between the cable centres in any short-circuit test and associated new figures; c) Specification of the cable to be used in short-circuit testing and relaxation of the ambient temperature limits for the test; d) Additional requirement to photograph the short-circuit test arrangement before and after the test and to record more complete details of the cable used; e) Revised parameters for the test of resistance to UV light. This edition also includes the following editorial changes with respect to the previous edition: f) Revised and updated normative references and bibliography; g) Editorial clarification of definitions; h) Editorial clarification of procedures for selection of test samples and the testing of cleats designed for more than one cable; i) Relaxation of some mandrel material requirements; j) Clarification of the inspection requirements following a short-circuit test and adding the option of either a.c. or d.c. voltage testing following a second short-circuit; k) Clarification that the resistance to corrosion test applies to all types of fixing; l) New cleat example illustration; m) Limitations of use of the formulae in Annex B added.

Cable cleats for electrical installations

ICS
29.120.20
CCS
发布
2016-02-12
实施
2016-03-28 (7)

本标准规定了250V及以下免剥皮快速电线连接器的术语和定义、一般要求、产品分类、产品型号与表示方法、性能要求、检验方法、检验规则、标签和标志、包装、运输及贮存。 本标准适用于0.5mm2 ~6.0mm2 250V及以下免剥皮快速电线连接器,不适用于防水,不能重复使用。

250V and below non-stripping fast wire connector

ICS
29.120.20
CCS
L23
发布
2015-11-05
实施
2016-02-05

Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV; German version EN 50393:2015

ICS
29.120.20
CCS
K13;L24
发布
2015-10
实施

This part of IEC 60999 applies to screw-type and screwless-type clamping units for connecting devices, either as separate entities or as integral parts of equipment, for the connection of electrical copper conductors (complying with IEC 60228), rigid (solid or stranded) and/or flexible, having a cross-sectional area of 0,2 mm² up to and including 35 mm² and equivalent AWG sizes with a rated voltage not exceeding 1 000 V a.c. with a frequency up to and including 1 000 Hz, and 1 500 V d.c. It applies to clamping units primarily suitable for connecting unprepared conductors. This standard does not apply to clamping units a) for connection by crimping or soldering; b) for data and signalling circuits; c) for flat quick-connect terminations, insulation-piercing connecting devices and twist-on connecting devices, which are covered by IEC 61210 [3]1), IEC 60998-2-3 [1] and IEC 60998-2-4 [2] respectively.

Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included)

ICS
29.120.20
CCS
发布
2015-09-03
实施

This part of IEC 60352 is applicable to insulation piercing connections made with stranded wires and tinsel-wire, flat conductors and flat flexible circuitries for use in telecommunication equipment and in electronic devices employing similar techniques. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. The object of this standard is to – determine the suitability of insulation piercing connections under specified mechanical, electrical, and atmospheric conditions; – provide a means of comparing test results when the tools used to make the connections are of different designs or manufacture. There are different designs and materials for insulation piercing terminations in use. For this reason only fundamental parameters of the termination, the performance requirements of the conductor and the complete connection are specified in this standard.

Solderless connections - Part 6: Insulation piercing connections - General requirements, test methods and practical guidance

ICS
29.120.20
CCS
发布
2015-09-03
实施

This part of IEC 61995, which is to be read in conjunction with IEC 61995-1, applies to devices for the connection of luminaires (DCL) 250 V, 6 A a.c. intended for household and similar purposes, for the electrical connection to final circuits rated not more than 16 A, without providing mechanical support for the luminaire.

Devices for the connection of luminaires for household and similar purposes - Part 2: Standard sheets for DCL

ICS
29.120.20
CCS
发布
2015-09-03
实施

Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV

ICS
29.120.20
CCS
L24
发布
2015-02-28
实施
2015-02-28

Tubular end-sleeves with plastic sleeve, Corrigendum to DIN 46228-4:1990-09

ICS
29.120.20
CCS
L24
发布
2015-02
实施

This International Standard applies to non-insulated flat quick-connect terminations consisting of a male tab of size 2,8 mm, 4,8 mm, 6,3 mm or 9,5 mm with hole or dimple detents and a mating female connector for use as either an incorporated or an integrated part of an equipment or of a component, or as a separate entity. This standard establishes uniform requirements for the dimensions, performance characteristics and test program. The connected electrical copper conductors shall be flexible or rigid stranded, having a crosssectional area up to and including 6 mm2 or rigid solid having a cross-sectional area up to and including 2,5 mm2. This standard shall not be used for connecting aluminum conductors. The rated voltage shall not exceed 1 000 V a.c. with a frequency up to and including 1 000 Hz, and 1 500 V d.c., and having the temperature limits applicable to materials used within this standard. NOTE 1 This standard, where applicable, may be used for conductors made of material other than copper. NOTE 2 For reasons of safety, it is recommended that flat quick-connect terminations beyond the scope of this standard should not be interchangeable with those of this standard. NOTE 3 This standard does not apply to female connectors with positive locking means. NOTE 4 The flat quick-connect terminations covered by this standard are not intended to be disconnected by pulling on the cable. NOTE 5 Annex D provides additional information on non international units.

Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements

ICS
29.120.20
CCS
发布
2014-12-25
实施

Replacement: This International Standard applies to twist-on connecting devices for connecting two or more unprepared rigid and/or flexible copper conductors having a cross-sectional area of 0,5 mm2 up to and including 16 mm2 and complying with IEC 60228, the total cross-sectional area of the connected conductors not exceeding 35 mm2. It covers low voltage circuits up to 1 000 V a.c. and 1 500 V d.c. where electrical energy is utilized for household and similar purposes. This standard covers TOCDs primarily designed for application by hand. However, certain TOCDs, for example for large cross-sections, may require the use of a tool designed for that particular TOCD. NOTE In the UK, TOCDs must also be suitable for connecting 2 or more unprepared flexible cables, including a flexible cable having a cross sectional area of 1,25 mm2 complying with BS 6500. Wires and cables in the USA do not presently comply to IEC 60228.

Connecting devices for low-voltage circuits for household and similar purposes - Part 2-4: Particular requirements for twist-on connecting devices

ICS
29.120.20
CCS
发布
2014-12-25
实施

This clause of Part 1 is applicable. Addition: This standard applies to connecting devices with screwless-type clamping units primarily suitable for connecting unprepared conductors. In this standard, screwless-type terminals are referred to as terminals. NOTE This standard does not include insulation piercing connecting devices (IEC 60998-2-3), twist-on connecting devices (IEC 60998-2-4) and flat, quick-connect terminations (IEC 60998-2-5).

Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units

ICS
29.120.20
CCS
发布
2014-12-25
实施

This clause of IEC 60320-1 is replaced as follows: This standard is applicable to two-pole appliance couplers for a.c. only, with or without earthing contact, with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A, for household and similar general purposes and intended for incorporation or integration within electric appliances or other electric equipment of multi-part construction for 50 Hz or 60 Hz supply which depend on the weight of the appliance to ensure correct engagement. NOTE 1 Appliance couplers complying with this standard are suitable for use in appliances which are used in an ambient temperature not normally exceeding 25 °C but occasionally reaching 35 °C. However the ambient temperature surrounding the appliance coupler may exceed these figures and is to be declared by the manufacturer. It is possible that the maximum working ambient temperature for the appliance inlet and for the connector may be different. NOTE 2 Appliance couplers dependent on appliance weight for engagement may be subject to spillage of liquid in normal use. They are classified according to whether protection against liquid spillage is provided, when installed in accordance with the manufacturer’s installation instructions. NOTE 3 If appliance inlets according to this standard are used with appliances or other equipment which may be subject to spillage of liquid affecting the appliance inlet when the functioning part of the appliance or equipment is seated on its power base, then protection against moisture is to be provided by the equipment. NOTE 4 References to standard sheets within IEC 60320-1 do not apply to appliance couplers dependent on appliance weight for engagement. NOTE 5 Special constructions may be required: – in locations where special conditions may prevail, for example, in ships, vehicles and the like; – in hazardous locations, for example, where explosions are likely to occur.

Appliance couplers for household and similar general purposes - Part 2-4: Couplers dependent on appliance weight for engagement

ICS
29.120.20
CCS
发布
2014-12-25
实施

This clause of Part 1 is applicable except as follows: Addition: This standard applies to connecting devices with insulation piercing clamping units primarily suitable for connecting insulated unprepared conductors. In the connecting operation the insulation of the conductor is pierced, bored through, cut through, removed, displaced or made ineffective in some other manner at the point or points of contact. NOTE In the text of this standard, connecting devices with insulation piercing clamping units are referred to as IPCDs (insulation-piercing connecting devices).

Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units

ICS
29.120.20
CCS
发布
2014-12-25
实施

This clause of Part 1 is applicable except as follows: Addition: This standard applies to connecting devices with screw-type clamping units primarily suitable for connecting unprepared conductors.

Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units

ICS
29.120.20
CCS
发布
2014-12-25
实施

This International Standard applies to screw-type and screwless-type clamping units of any material for connecting devices, either as separate entities or as integral parts of products, for the connection of unprepared electrical aluminium (bare or plated) and copper-clad aluminium conductors (complying with IEC 228), rigid (solid and stranded), having a cross-sectional area of 2,5 mm2 up to and including 50 mm2, and equivalent AWG conductors,with a rated voltage not exceeding 1 000 V a.c. up to and including 1 000 Hz, and 1 500 V d.c. This standard also applies to aluminium bodied clamping units for the connection of rigid (solid and stranded) and flexible copper conductors (complying with IEC 228), 0,5 mm 2 up to and including 35 mm2 and equivalent AWG conductors. It contains the minimum requirements applicable to clamping units primarily suitable for connecting conductors. This standard does not apply to clamping units: a) for connection by crimping, brazing, soldering or welding; b) for data and signalling circuits; c) for flat quick-connect terminations, insulation piercing-type connections or twist-on connecting devices, for which separate pa rts exist or are under consideration. NOTES 1 In the USA and Canada, subclause 5.5.2 covering treatment of the specimens and conductors to be tested is not acceptable. 2 Flexible aluminium conductors are not covered by this standard. Upon the development of such conductors their inclusion will be considered.

Connecting devices - Devices for the connection of aluminium conductors in clamping units of any material and copper conductors in aluminium bodied clamping units

ICS
29.120.20
CCS
发布
2014-12-25
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号