Electrical accessories — Circuit-breakers for overcurrent protection for household and similar installations —Part 3: Circuit-breakers for DC operation

ICS
29.120.50
CCS
发布
2021-07-01
实施

IEC 62873-3-1:2016(E) applies to RCDs equipped with screwless terminals, for current not exceeding 20 A primarily suitable for connecting unprepared (see 3.5) copper conductors of cross-section up to 4 mm2. This part of IEC 62873 cannot be used alone but it is intended to be applied together with an RCD product standard (IEC 61008-1 or IEC 61009-1) if an RCD is equipped with screwless terminals.

Residual current operated circuit-breakers for household and similar use - Part 3-1: Particular requirements for RCDs with screwless-type terminals for external copper conductors

ICS
29.120.50
CCS
发布
2021-07-01
实施

IEC 62873-3-2:2016(E) applies to RCDs equipped with flat quick-connect terminations consisting of a male tab (see 3.2) with nominal width 6,3 mm and thickness 0,8 mm, to be used with a mating female connector for connecting electrical copper conductors according to the manufacturer's instructions, for rated currents up to and including 16 A.

Residual current operated circuit-breakers for household and similar use - Part 3-2: Particular requirements for RCDs with flat quick-connect terminations

ICS
29.120.50
CCS
发布
2021-07-01
实施

IEC 63024:2017 applies to automatic reclosing devices (ARDs) for household and similar uses, for rated voltage not exceeding 440 V AC, and which are intended to be used in combination with circuit-breakers, RCCBs and RCBOs, and designed either for factory assembly or for assembly on site. These devices are intended to reclose main protective devices (MPDs) such as circuit-breakers complying with IEC 60898-1 and/or IEC 60898-2, RCCBs complying with IEC 61008-1 and/or IEC 62423, and RCBOs complying with IEC 61009-1 and/or IEC 62423 after tripping of those devices in order to re-establish continuity of service.

Requirements for automatic reclosing devices (ARDs) for circuit breakers, RCBOs-RCCBs for household and similar uses

ICS
29.120.50
CCS
发布
2021-07-01
实施

Electrical accessories — Circuit-breakers for overcurrent protection for household and similar installations —Part 3: Circuit-breakers for DC operation

ICS
29.120.50
CCS
发布
2021-07-01
实施

Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses; Corrigendum 1

ICS
29.120.50
CCS
K31
发布
2021-07-01
实施

IEC 60127-8:2018 relates to fuse resistors with particular overcurrent protection rated up to AC 500 V and/or DC 500 V for printed circuits and other substrate systems, used for the protection of electric appliances, electronic equipment and component parts thereof, normally intended to be used indoors. It does not apply to fuse resistors with particular overcurrent protection for appliances intended to be used under special conditions, such as in a corrosive or explosive atmosphere. The object of this part of IEC 60127 is a) to establish uniform requirements for fuse resistors with particular overcurrent protection so as to protect appliances or parts of appliances in the most suitable way; b) to define the performance of the fuse resistors with particular overcurrent protection, so as to give guidance to manufacturers of electrical appliances and electronic equipment and to ensure replacement of fuse resistors with particular overcurrent protection by those of similar dimensions and characteristics; c) to establish uniform test methods for fuse resistors with particular overcurrent protection, so as to allow verification of the values (for example rated dissipation, functioning characteristic and rated breaking capacity values) specified by the manufacturer. This part of IEC 60127 applies in addition to the requirements of IEC 60127-1. This first edition of IEC 60127-8 cancels and replaces IEC PAS 60127-8:2014. This international standard is to be used in conjunction with IEC 60127-1. Keywords: Miniature Fuses, Fuse-Resistors, Overcurrent Protection

Miniature fuses - Part 8: Fuse resistors with particular overcurrent protection

ICS
29.120.50
CCS
发布
2021-07-01
实施

IEC 60099-9:2014 applies to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit overvoltages in HVDC converter stations of two terminal, multiterminal and back-to-back type up to and including an operating voltage of 1 100 kV. The standard applies in general to porcelain-housed and polymer-housed type arresters but also to gas-insulated metal enclosed arresters (GIS-arresters) solely used as d.c. bus and d.c. line/cable arresters. Arresters for voltage source converters are not covered. Arresters applied on the a.c. systems at the converter station and subjected to power-frequency voltage of 50 or 60 Hz principally without harmonics are tested as per IEC 60099-4. The arresters on a.c.-filters are tested according to this standard. Keywords: testing of gapless metal-oxide surge arrestors for HVDC converter stations

Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations

ICS
29.120.50
CCS
发布
2021-07-01
实施

IEC 60282-1:2020 applies to all types of high-voltage current-limiting fuses designed for use outdoors or indoors on alternating current systems of 50 Hz and 60 Hz and of rated voltages exceeding 1 000 V. This eighth edition cancels and replaces the seventh edition published in 2009. This edition includes the following significant technical changes with respect to the previous edition: – additional information concerning thermally operated strikers; – the division of ratings, characteristics and type tests into those applicable to all fuses and those applicable to particular fuse-link types and applications; – adjustment of Series II voltages and tests to meet present North American standard system voltages and applications; – clarification of requirements for fuse-links used in surrounding temperatures above 40 °C; and – clarification of homogeneous requirements for fuse-links containing one element.

High-voltage fuses - Part 1: Current-limiting fuses

ICS
29.120.50
CCS
发布
2021-07-01
实施

IEC 62873-1:2017 The IEC 62873 series covers available common standards intended to be used in conjunction with or for the preparation of RCD (residual current device) standards. This part of IEC 62873 defines the methodology and processes used when producing standards based on a new approach (hereafter referred to as blocks and modules) aiming at harmonizing a family of standards, thus avoiding mistakes, inconsistencies or discrepancies within this family of standards. The family of standards considered in this document consists of standards for RCCBs (Residual Current Circuit-Breakers without overcurrent protection), RCBOs (Residual Current Circuit-Breakers with overcurrent Protection), and general safety requirements for residual current operated protective devices (namely IEC 61008-1, IEC 61009-1 and IEC TR 60755).

Residual current operated circuit-breakers for household and similar use - Part 1: Outline of blocks and modules for residual current device standards

ICS
29.120.50
CCS
发布
2021-07-01
实施

IEC 62873-2:2016(E) provides the terms and definitions used in RCD product standards.

Residual current operated circuit-breakers for household and similar use - Part 2: Residual current devices (RCDs) - Vocabulary

ICS
29.120.50
CCS
发布
2021-07-01
实施

IEC 62955:2018 applies to residual direct current detecting devices (RDC-DD) for permanently connected AC electric vehicle charging stations (mode 3 charging of electric vehicles, according to IEC 61851-1 and IEC 60364-7-722), hereafter referred to as RDC-MD (residual direct current monitoring device) or RDC-PD (residual direct current protective device), for rated voltages not exceeding 440 V AC with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A.

Residual direct current detecting device (RDC-DD) to be used for mode 3 charging of electric vehicles

ICS
29.120.50
CCS
发布
2021-07-01
实施

IEC 62873-3-3:2016(E) applies to RCDs equipped with screw-type terminals of copper - or of alloys containing at least 58 % of copper (if worked cold) or at least 50 % of copper (if worked otherwise), or of other metal or suitably coated metal, no less resistant to corrosion than copper and having mechanical properties no less suitable - for use with untreated aluminium conductors, or with screw-type terminals of aluminium material for use with copper or aluminium conductors.

Residual current operated circuit-breakers for household and similar use - Part 3-3: Specific requirements for RCDs with screw-type terminals for external untreated aluminium conductors and with aluminium screw-type terminals for use with copper or wit...

ICS
29.120.50
CCS
发布
2021-07-01
实施

Electrical accessories - Residual current monitors (RCMs) - Part 1: RCMs for household and similar uses (IEC 62020-1:2020)

ICS
29.120.50
CCS
发布
2021-06-30
实施
2021-06-30

Residual current devices with or without overcurrent protection for socket-outlets for household and similar uses

ICS
29.120.50
CCS
发布
2021-06-24
实施
2021-06-24

Miniature fuses - Part 6: Fuse-holders for miniature fuse-links (IEC 32C/596/CDV) (english version)

ICS
29.120.50
CCS
发布
2021-06-01
实施
2021-06-01

This standard contains the German version of the European Standard EN IEC 61643-331:2020 and is identical with the International Standard IEC 61643-331:2020. It describes performance requirements and test methods for metal oxide varistors (MOV) which are used for the design and t

Components for low-voltage surge protection - Part 331: Performance requirements and test methods for metal oxide varistors (MOV) (IEC 61643-331:2020); German version EN IEC 61643-331:2020

ICS
29.120.50
CCS
发布
2021-06-00
实施
2021-06-01

1   Scope This British Standard specifies dimensions and performance requirements for general purpose cartridge fuse links of current ratings not exceeding 13 A for domestic and similar purposes (primarily for use in plugs complying with the requirements of BS 1363) on declared supply voltages not exceeding 250 V (see 4.5 ) at a nominal frequency of 50 Hz or 60 Hz. It does not cover fuse bases or fuse holders for use with these fuse links. Text deleted The object of this specification is to standardize the characteristics, construction, tests and markings of fuse links coming within its scope. In particular to standardize: • the rated voltage; • the rated currents; • the rated power loss; • the time/current zones and conventional currents; • the rated breaking capacity ; and • the dimensions.

General purpose fuse links for domestic and similar purposes (primarily for use in plugs). Specification

ICS
29.120.50
CCS
发布
2021-05-31
实施
2021-05-31

This Standard applies to Class A, single- and three-phase, ground-fault circuit-interrupters intended for protection of personnel, for use only in grounded neutral systems in accordance with the National Electrical Code (NEC), ANSI/NFPA 70, the Canadian Electrical Code, C22.1 (CEC), and Electrical Installations (Use), NOM-001-SEDE. These devices are intended for use on alternating current (AC) circuits of 120 V, 208Y/120 V, 120/240 V, 127 V, or 220Y/127 V, 60 Hz circuits.Note: In Canada, the text "intended for protection of personnel" is excluded. These requirements do not cover ground-fault circuit-interrupters intended for use in circuits served by a transformer having windings wholly insulated from each other. This Standard applies to all Class A ground-fault circuit-interrupters. These Class A GFCIs are permitted to be integrated into other devices, in which case, besides complying with this Standard, these devices are to comply with the corresponding applicable Standard for the device in question. This Standard includes minimum requirements for the function, construction, performance, and markings of ground-fault circuit-interrupters included in the scope. This Standard is intended to cover only Class A GFCI devices.

Ground-fault circuit-interrupters

ICS
29.120.50
CCS
K31
发布
2021-05-05
实施
0000-00-00

ITU-T K.117 - Long reach single twisted-pair Ethernet resistibility testing

ICS
29.120.50
CCS