29.130.10 高压开关装置和控制器 标准查询与下载



共找到 858 条与 高压开关装置和控制器 相关的标准,共 58

IEC TR 62271-312:2021(E) refers to high-voltage / low-voltage prefabricated substations (hereinafter prefabricated substations) as specified in IEC 62271-202:2014. This document, among other options as agreed between manufacturer and user, can be used for the transferability of type tests performed on one or more prefabricated substations with a defined set of ratings and arrangement of components to another prefabricated substation with a different set of ratings or different arrangement of components. It supports the selection of appropriate representative test objects for that purpose in order to optimize the type testing procedure for a consistent conformity assessment. This document utilises a combination of sound technical and physical principles, manufacturer and user experience and mutually agreed upon methods of calculation to establish pragmatic guidance for the transferability of type test results, covering various design and rating aspects.

High-voltage switchgear and controlgear - Part 312: Guidance for the transferability of type tests of high-voltage/low-voltage prefabricated substations

ICS
29.130.10
CCS
发布
2023-05-03
实施

This part of IEC 62271 is applicable to AC switching devices designed for indoor or outdoor installation, for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above (including circuit-breakers in accordance with IEC 62271-100) that are used to switch high-voltage motor currents and shunt reactor currents and also to high-voltage contactors used to switch high-voltage motor currents as covered by IEC 62271-106. Switching unloaded transformers, i.e. breaking transformer magnetizing current, is not considered in this document. The reasons for this are as follows: a) Owing to the non-linearity of the transformer core, it is not possible to correctly model the switching of transformer magnetizing current using linear components in a test laboratory. Tests conducted using an available transformer, such as a test transformer, will only be valid for the transformer tested and cannot be representative for other transformers. b) As detailed in IEC TR 62271-306, the characteristics of this duty are usually less severe than any other inductive current switching duty. Such a duty can produce severe overvoltages within the transformer winding(s) depending on the re-ignition behaviour of the switching device and transformer winding resonance frequencies. document. the application of test results according to this document, on the switching of neutral reactor earthed reactors (4-leg reactor scheme), is discussed in IEC TR 62271-306.

High-voltage switchgear and controlgear. Inductive load switching

ICS
29.130.10
CCS
发布
2023-04-30
实施
2023-04-30

IEC 62271-110:2023 is available as IEC 62271-110:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62271-110:2023 is applicable to AC switching devices designed for indoor or outdoor installation, for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V and applied for inductive current switching. It is applicable to switching devices (including circuit-breakers in accordance with IEC 62271-100) that are used to switch high‑voltage motor currents and shunt reactor currents and also to high-voltage contactors used to switch high-voltage motor currents as covered by IEC 62271-106. This fifth edition cancels and replaces the fourth edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: references to IEC 62271-100 and IEC 62271-106 have been updated to the latest editions.

High-voltage switchgear and controlgear - Part 110: Inductive load switching

ICS
29.130.10
CCS
发布
2023-04-21 (7)
实施
2023-07-20 (7)

本文件规定了铠装移开式金属封闭开关设备的术语和定义、技术要求、试验方法、检验规则、标志、包装、运输及贮存。 本文件适用于铠装移开式金属封闭开关设备的设计、制造和检验。

Armored removable metal-enclosed switchgear

ICS
29.130.10
CCS
C382
发布
2023-04-19
实施
2023-04-19

本文件规定了固体绝缘环网开关柜的术语和定义、技术要求、试验方法、检验规则、标志、包装、运输及贮存。 本文件适用于固体绝缘环网开关柜的设计、制造和检验。

Solid insulated ring network switchgear

ICS
29.130.10
CCS
C382
发布
2023-04-19
实施
2023-04-19

High-voltage switchgear and controlgear - Part 110: Inductive load switching

ICS
29.130.10
CCS
发布
2023-03-16
实施
2023-03-16

High-voltage switchgear and controlgear - Part 110: Inductive load switching

ICS
29.130.10
CCS
发布
2023-03-16
实施

High-voltage switchgear and controlgear - ALL PARTS

ICS
29.130.10
CCS
发布
2023-03-16
实施
2023-03-16

BS EN IEC 62271-208. High-voltage switchgear and controlgear - Part 208. Methods to quantify the steady state, power-frequency electromagnetic fields generated by HV switchgear assemblies and HV/LV prefabricated substations

ICS
29.130.10
CCS
发布
2023-03-14
实施
2023-03-14

BS EN IEC 62271-200 AMD 1. High-voltage switchgear and controlgear - Part 200. AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

ICS
29.130.10
CCS
发布
2023-03-01
实施
2023-03-01

本文件规定了基于高耦合分裂电抗器的高压交流故障电流限制器专用断路器的各项技术要求,包括额定值、设计与结构、型式试验、出厂试验、选用导则、安装、运行和维护规则等。 本文件适用于设计安装在户内或户外且运行在电压3 kV及以上、频率50 Hz的基于高耦合分裂电抗器的高压交流故障电流限制器专用断路器。 本文件也适用于该类专用断路器的操动机构及其辅助设备。

Technical specifications for limited purpose circuit-breaker of high-voltage alternating-current fault current limiters based on high coupled split reactor

ICS
29.130.10
CCS
C382
发布
2022-12-30
实施
2022-12-30

本文件规定了基于限流电抗器的高压交流故障电流限制器专用断路器的各项技术要求,包括额定值、设计与结构、试验要求、选用、安装、运行和维护规则等。 本文件适用于设计安装在户内或户外且运行在频率50 Hz、电压3 kV及以上系统中的基于限流电抗器的高压交流故障电流限制器专用断路器。

Technical specifications for limited purpose circuit breaker of HVAC fault current limiter based on current-limiting reactor

ICS
29.130.10
CCS
C382
发布
2022-12-30
实施
2022-12-30

本文件规定了 12 kV~40.5 kV 新能源用智能高压交流组合式断路器(以下简称组合式断路器)的术语和定义、 基本要求、 环境条件、 额定值、 技术要求、试验方法、检验规则、 标志、包装、运输和贮存以及质量承诺。 本文件适用于额定电压为12 kV~40.5 kV、安装在户内、额定频率为50 Hz、应用于光伏发电、风力发电及储能等领域的组合式断路器,额定频率为60 Hz的组合式断路器,可参考执行本文件。

Intelligent high-voltage alternating-current combined vacuum circuit-breakers applied in new energy for rated voltages above 12 kV and up to and including 40.5 kV

ICS
29.130.10
CCS
C382
发布
2022-12-08
实施
2023-03-24

本文件规定了高压直流高速并列开关的额定值、设计与结构、型式试验、出厂试验、特殊试验、交接试验等。 本文件适用于安装在户内或户外且运行电压等级为±800 kV 及以下的高压多端直流输电系统中的高压直流高速并列开关。本文件也适用于高压直流高速并列开关的操动机构和辅助设备。

High voltage DC high speed parallel switch

ICS
29.130.10
CCS
D4420
发布
2022-12-05
实施
2023-03-01

1   Scope This document applies to pressurized partitions used in indoor and outdoor installations of high-voltage AC and DC switchgear and controlgear with rated voltages (Ur) above 1 kV AC / 1,5 kV DC and with design pressure higher than 300 kPa, where the gas is used principally for its dielectric and/or arc-quenching properties. The partitions comprise pressurized barriers in electrical equipment not necessarily limited to the following examples: — circuit-breakers; — switch-disconnectors; — disconnectors; — earthing switches; — current transformers; — voltage transformers; — surge arresters; — busbars and connections; — cable connections/terminations; — cable bushings.

High-Voltage switchgear and controlgear. Insulating pressurised partitions for gas filled metal enclosures

ICS
29.130.10
CCS
发布
2022-11-30
实施
2022-11-30

1   Scope This part of IEC 62271 specifies requirements for gas-insulated metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas or gas mixture other than air at atmospheric pressure, for alternating current of rated voltages above 52 kV, for indoor and outdoor installation, and for service frequencies up to and including 60 Hz. For the purpose of this document, the terms “GIS” and “switchgear” are used for “ gas-insulated metal-enclosed switchgear ”. The gas-insulated metal-enclosed switchgear covered by this document consists of individual components intended to be directly connected together and able to operate only in this manner. This document completes and amends, if applicable, the various relevant standards applying to the individual components constituting GIS.

High-voltage switchgear and controlgear. AC gas-insulated metal-enclosed switchgear for rated voltages above 52 kV

ICS
29.130.10
CCS
发布
2022-10-31
实施
2022-10-31

High-voltage switchgear and controlgear —Part 100: Alternating-current circuit-breakers

ICS
29.130.10
CCS
发布
2022-10-21
实施

High-voltage switchgear and controlgear —Part 100: Alternating-current circuit-breakers

ICS
29.130.10
CCS
发布
2022-10-21
实施

1   Scope This part of IEC 62271 specifies the service conditions, rated characteristics, general structural requirements and test methods of enclosed high-voltage prefabricated substations . These prefabricated substations are cable-connected to AC high-voltage networks with an operating voltage up to and including 52 kV and power frequencies up to and including 60 Hz. They can be manually operated from inside (walk-in type) or from outside (non-walk-in type). They are designed for outdoor installation at locations with public accessibility and where protection of personnel is provided. These prefabricated substations can be situated at ground level or partially or completely below ground level. The last are also called "underground prefabricated substations ". In general, two types of prefabricated substations are considered in this document: – high-voltage switchgear prefabricated substations ; – high-voltage/low-voltage transformer prefabricated substations (step-up and step-down). A high-voltage switchgear prefabricated substation comprises an enclosure containing in general the following electrical components:

High-voltage switchgear and controlgear. AC prefabricated substations for rated voltages above 1 kV and up to and including 52 kV

ICS
29.130.10
CCS
发布
2022-09-30
实施
2022-09-30

1   Scope This part of IEC 62271 specifies the service conditions, rated characteristics, general structural requirements and test methods of the assemblies of the main electrical functional units of a high-voltage transformer substation, duly interconnected, for AC voltages up to and including 52 kV on the high-voltage side and service frequency 50 Hz or 60 Hz. The CEADS is cable-connected to the high-voltage network for indoor and outdoor applications of restricted access. A CEADS as defined in this document is designed and tested to be a single product with a single serial number and one set of documentation. The functions of a CEADS are: — high-voltage/high-voltage or high-voltage/low-voltage transformation; and some or all the following: — switching and control for the operation of the high-voltage circuit(s); — switching and control for the operation of the low-voltage circuit(s); — protection of the power transformer functional unit . The main functions are integrated in the following functional units : ...

High-voltage switchgear and controlgear - Compact Equipment Assembly for Distribution Substation (CEADS) for AC voltages up to 52 kV

ICS
29.130.10
CCS
发布
2022-09-30
实施
2022-09-30



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号