29.130.99 其他开关装置和控制器 标准查询与下载



共找到 72 条与 其他开关装置和控制器 相关的标准,共 5

Comment responses and substantive change for the proposed Eleventh Edition of the Standard for Switchboards, UL 891. This is a proposed tri-national harmonized standard.

UL Standard for Safety Switchboards

ICS
29.130.99
CCS
K36
发布
2007-05-11
实施

This standard covers power switchgear equipment that is converted from a qualified design. It provides direction and guidance in those conversions and specifies required design verification in accordance with applicable American National Standards Institute (ANSI), National Electrical Manufacturers Association (NEMA), Underwriters Laboratories Inc. (UL), or IEEE standards. This standard also recognizes that production/field testing does not provide design verification. This can only be accomplished by means of design testing and technical evaluation.

Standard Requirements for Conversion of Power Switchgear Equipment

ICS
29.130.99
CCS
K31
发布
2007
实施

This standard describes site preparation and installation of medium-voltage switchgear rated 2, 400 Volts to 34, 500 Volts.

Standard for Installing Medium-Voltage Switchgear

ICS
29.130.99
CCS
K31
发布
2006-07-27
实施

Recirculation of Comments received and substantive changes resulting from comments regarding the proposed revisions to the Eleventh Edition of the Standard for Panelboards, UL 67.

CSDS 01/27/2006 (26p)

ICS
29.130.99
CCS
发布
2006-01-01
实施

Covers ratings, construction, and testing of dead-front control switchboards containing but not limited to devices such as switches, control devices, instrumentation, metering, monitoring, protective and auxiliary relays, and regulating devices and accessories. It includes, but is not specifally limited to, switchboards for the control and protection of apparatus used for or associated with power generation, conversion, transmission, and distribution.

Standard for Control Switchboards

ICS
29.130.99
CCS
K31
发布
2005-10-7
实施

1.1.1 This Standard applies to switchboards nominally rated at 600 V or less and intended for use in accordance with the Canadian Electrical Code, Part 1 (CE Code, Part 1), the National Electrical Code (NEC), ANSI/NFPA 70, and the Mexican Standard for Electrical Installations (Utility), NOM-001-SEDE. 1.1.2 In this standard the term switchboard is intended to refer to a dead-front switchboard. 1.1.3 These requirements do not cover the following switchboard types: preset and dimmer control (theater), live front, railway control or electrification; or constructions intended only for receiving motor control center units. 1.1.4 These requirements cover switchboards for use on circuits having available rms symmetrical short-circuit currents of not more than 200000 A.

Switchboards

ICS
29.130.99
CCS
K36
发布
2005-07-26
实施

Comment responses and substantive change for the proposed Eleventh Edition of the Standard for Switchboards, UL 891. This is a proposed tri-national harmonized standard.

Dead-Front Switchboards

ICS
29.130.99
CCS
K36
发布
2005-01-01
实施

Recirculation of Comments received and substantive changes resulting from comments regarding the proposed revisions to the Eleventh Edition of the Standard for Panelboards, UL 67.

CSDS 11/23/2005 (16p); CSDS 7/15/05 (42p)

ICS
29.130.99
CCS
发布
2005-01-01
实施

1.1 These requirements apply to controls that employ solid-state devices and are intended for specified safety-related protective functions. 1.2 These requirements address the potential risks unique to the electronic nature of a control. Equipment or components employing an electronic feature shall also comply with the basic construction and performance requirements contained in the applicable end-product or component standard. These requirements are intended to supplement applicable end-product or component standards and are not intended to serve as the sole basis for investigating the risks of fire, electric shock, or injury to persons associated with a control. 1.3 These requirements do not cover controls covered by end-product standards in which an electronic control investigation is specified. 1.4 Sections 9 - 22 contain standardized test methods for investigating the performance of an electronic control when subjected to particular environmental stresses. The suitability of each test to a given control shall be determined by the end-product standard(s). Determination shall include an assessment of: a) Whether the control will be exposed to a particular environmental stress in its application, and b) Whether the response of the control to a particular environmental stress is relevant to its intended safety-related protective function in its application.

UL Standard for Safety Tests for Safety-Related Controls Employing Solid-State Devices Third Edition; Reprint with revisions through and including April 2, 2008

ICS
29.130.99
CCS
L10
发布
2004
实施

Applies to enclosed assemblies of single-phase and three-phase, dead-front and live-front, subsurface, vault, and padmounted, load-interrupter switches with or without protective devices such as fuses or fault interrupters, up to 38 kV Rated Maximum Voltage.

Standard Requirements for Subsurface, Vault, and Padmounted Load-Interrupter Switchgear and Fused Load-Interrupter Switchgear for Alternating Current Systems up to 38 kV

ICS
29.130.99
CCS
K31
发布
2003-08-07
实施

1.1 These requirements cover component electronic controls intended to be factory installed on or in appliances and other utilization equipment rated 600 V or less, used in ordinary dry locations as defined in the National Electrical Code, NFPA 70, and that comply with the requirements for such appliances and equipment. 1.2 For a control covered by this standard, it is assumed that: a) No voltage greater than 600 V above ground will be present in a control, b) An isolation transformer, if provided, will generally furnish power at a lower potential than the primary voltage, and c) The output of the control will not be located in a circuit operating at greater than 600 V above ground in the end-use product. If conditions other than these are provided, consideration shall be given to the need for additional requirements.

UL Standard for Safety Solid-State Controls for Appliances

ICS
29.130.99
CCS
K32
发布
2003-04-30
实施

Recirculation of Comments received and substantive changes resulting from comments regarding the proposed revisions to the Eleventh Edition of the Standard for Panelboards, UL 67.

8/19/2003 (12p), 1/28/2003 (12p)

ICS
29.130.99
CCS
发布
2003-01-01
实施

American National Standard - Preferred Ratings and Related Required Capabilities for Indoor AC Medium-Voltage Switches Used in Metal-Enclosed Switchgear

ICS
29.130.99
CCS
K31
发布
2003
实施

Comment responses and substantive change for the proposed Eleventh Edition of the Standard for Switchboards, UL 891. This is a proposed tri-national harmonized standard.

Dead-Front Switchboards

ICS
29.130.99
CCS
K36
发布
2003
实施

Recirculation of Comments received and substantive changes resulting from comments regarding the proposed revisions to the Eleventh Edition of the Standard for Panelboards, UL 67.

08/12/2002 (6p), 05/31/2002 (32p); 1/31/2002 (4p)

ICS
29.130.99
CCS
发布
2002-01-01
实施

Recirculation of Comments received and substantive changes resulting from comments regarding the proposed revisions to the Eleventh Edition of the Standard for Panelboards, UL 67.

08/12/2002 (6p), 05/31/2002 (32p); 1/31/2002 (4p)

ICS
29.130.99
CCS
发布
2002
实施

These requirements cover industrial control equipment for installation and use in hazardous (classified) locations, Class I, Division 1, Groups A, B, C, and D, and Class II, Division 1, Groups E, F, and G, in accordance with the National Electrical Code, NFPA 70. These requirements also cover explosion-proof electrical equipment for installation and use in Class I, Zone 1, Groups IIA, IIB, IIB plus Hydrogen, and IIC hazardous (classified) locations. Examples of industrial control equipment are: a) Manual and magnetic starters and controllers. b) Thermal- and magnetic-overload relays. c) Pushbutton stations, including selector switches and pilot lights. d) Control-circuit switches and relays. e) Float-, flow-, pressure-, and vacuum-operated switches. f) Resistors and rheostats. g) Proximity switches. h) Time-delay relays and switches. i) Resistors and rheostats intended for industrial heating and lighting, including those for motor-generator fields. j) Control devices intended for industrial heating and lighting. k) Variable-voltage autotransformers. These requirements apply to industrial control equipment for use in hazardous locations under the following atmospheric conditions: a) A minimum ambient temperature of minus 25 鳦 (minus 13 鳩), b) An oxygen concentration not greater than 21 percent by volume, and c) A nominal barometric pressure of one atmosphere.

08/23/2002 (10p)

ICS
29.130.99
CCS
发布
2002
实施

Recirculation of Comments received and substantive changes resulting from comments regarding the proposed revisions to the Eleventh Edition of the Standard for Panelboards, UL 67.

08/12/2002 (6p), 05/31/2002 (32p); 1/31/2002 (4p)

ICS
29.130.99
CCS
发布
2002
实施

Recirculation of Comments received and substantive changes resulting from comments regarding the proposed revisions to the Eleventh Edition of the Standard for Panelboards, UL 67.

6/29/2001 (14p), 3/30/2001 (10p)

ICS
29.130.99
CCS
发布
2001-01-01
实施

Recirculation of Comments received and substantive changes resulting from comments regarding the proposed revisions to the Eleventh Edition of the Standard for Panelboards, UL 67.

9/20/2000 (12p); 3/17/2000 (8p)

ICS
29.130.99
CCS
发布
2000-01-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号