33.120.20 导线和对称电缆 标准查询与下载



共找到 508 条与 导线和对称电缆 相关的标准,共 34

This technical report is a supplement to IEC 61156-1 Edition 3 (2007): Multicore and symmetrical pair/quad cables for digital communications – Part 1: Generic specification. This technical report covers the following topics following this standard: – the near-end crosstalk test methods and length correction procedures of 6.3.5; – the far-end crosstalk test methods and length correction procedures of 6.3.6; – the concatenation of measured cable segments, even if they are of different design. The final objective of this technical report is to describe the mathematics involved to model the concatenation of cable sections of different length, not based upon measurements but based upon the specification limits of the cables involved. This is required as a base foundation of the complete channel modelling, involving also the connectivity covered by IEC SC48B towards channels, as required and requested by ISO/IEC JTC1/SC25 WG3 for incorporation into ISO/IEC 11801:2002 [1] 1. This TR is informative and contains observations and recommendations applicable to using the length correction formulas for either measurements or modelling of balanced cables.

Multicore and symmetrical pair/quad cables for digital communications - Part 1-3: Electrical transmission parameters for modelling cable assemblies using symmetrical pair/quad cables

ICS
33.120.20
CCS
发布
2014-12-25
实施

This part of IEC 61156 which is a sectional specification applies to Capability Approval requirements for multicore and symmetrical pair cables for digital communication riser cables according to IEC 61156-1 and 61156-4. Clause 2 is related to the content of the Capability Manual. Clause 3 is related to the Quality Plans. Clause 4 is related to the maintenance of Capability Approval. NOTE Quality assessment belongs to the negotiation between customers and manufacturers. The following clause intends to be a guide when there is a request for a third party Capability Approval. However, it may be used also as the basis for second party or self-certification

Multicore and symmetrical pair/quad cables for digital communications - Part 4-2: Riser cables - Capability approval - Sectional specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

This part of IEC 61156, which is a sectional specification applies to Capability Approval requirements for cables for digital communications in horizontal floor wiring according to IEC 61156-1 and IEC 61156-2. Clause 2 is related to the content of the Capability Manual. Clause 3 is related to the Quality Plans. Clause 4 is related to the maintenance of Capability Approval. NOTE Quality assessment depends on the negotiation between customers and manufacturers. The following clause intends to be a guide when there is a request for a third party Capability Approval. However, it may be used also as the basis for second party or self-certification

Multicore and symmetrical pair/quad cables for digital communications - Part 2-2: Horizontal floor wiring - Capability Approval - Sectional specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

This sectional specification relates to IEC 62255-1. This standard is applicable to filled cables having a metallic screen over the cable core, a polyethylene jacket, copper conductors, and solid or cellular insulation. These cables are typically available in 6 to 300 pair. These cables are suitable for direct burial, installation into ducts, or installed aerially by lashing to a support strand. They may also be self-supporting by incorporation of an integral suspension strand. The cables covered by this specification are differentiated by bandwidth and are classified by having a maximum reference frequency of 30 MHz, 60 MHz, or 100 MHz.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 3: Filled cables - Sectional specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

This part of IEC 61196 applies to coaxial communications cables. It specifies test methods for determining the capacitance.

Coaxial communication cables - Part 1-103: Electrical test methods - Test for capacitance of cable

ICS
33.120.20
CCS
发布
2014-12-25
实施

This blank detail specification describes work area cord for class D applications, as defined in ISO/IEC 11801 as well as in the ISO/IEC 24702. This blank detail specification determines the layout and style for detail specifications describing cords with transmission characteristics up to 100 MHz for digital communications. Detail specifications, based on this blank detail specification, may be prepared by a national organization, a manufacturer, or a user. Test configuration applicable to cords is detailed in the IEC 61935-2. The designation "Category 5e" is used herein to describe an enhanced category 5 cable (see Clause 1 of IEC 61156-6).

Testing of balanced communication cabling in accordance with ISO/IEC 11801 - Part 2-20: Patch cords and work area cords - Blank detail specification for class D applications

ICS
33.120.20
CCS
发布
2014-12-25
实施

This blank detail specification determines the layout and style for detail specifications describing Multicore and symmetrical pair/quad filled drop cables for broadband digital communications. Detail specifications, based on the blank detail specification, may be prepared by a national organization, a manufacturer, or a user.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 5-1: Filled drop cables - Blank detail specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

This part of IEC 61156 which is a generic specification applies to Capability Approval requirements for multicore and symmetrical pair/quad cables for digital communications as specified in IEC 61156-1 series. It specifies the requirements for a manufacturer seeking approval of his capability to design (if applicable), manufacture, inspect, test and release multicore and symmetrical pair/quad cables for digital communications as defined in his Capability Manual. The manufacturer’s approval, which embodies all the relevant requirements of ISO 9001 and ISO 9002, is a prerequisite for granting Capability Approval but a manufacturer may apply for manufacturer’s approval and Capability Approval concurrently. NOTE 1 This standard was written, to be used in case of a third party certification. However, it may be used as the basis for a second party or for self-certification. NOTE 2 When certification is required, Capability Approval should be used according to that which is indicated below. It may also be used for a second party or for self-certification.

Multicore and symmetrical pair/quad cables for digital communications - Part 1-1: Capability Approval - Generic specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

This part of IEC 61156 which is a sectional specification relates to IEC 61156-1:2002. The cables are specifically intended for riser wiring up to category 5 (class D) as defined and specified in ISO/IEC 11801:1995. This specification defines individually screened or unscreened pairs/quads cables, with or without overall common screen. W hen installed vertically extra length requirements may be applicable and are defined in the relevant specifications. These cables are suitable for the various communication systems for which the reference is given in the relevant detail specification. The cables covered by this sectional specification are intended to operate with voltages and currents normally adopted for communication systems. These cables should not be connected to low impedance sources, for example, the public mains electricity supply. The recommended temperature range during installation is 0 oC to +50 oC. The normal operating temperature range is –40 oC to +60 oC. The actual temperatures range shall be indicated in the relevant detail specification.

Multicore and symmetrical pair/quad cables for digital communications - Part 4: Riser cables - Sectional specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

This part of IEC 61156 applies to Capability Approval requirements for cables for digital communications in horizontal floor wiring in accordance with generic specification IEC 61156-1-1 and Clause 4 of the sectional specification IEC 61156-5. Clause 2 refers to the content of the Capability Manual. Clause 3 refers to the Quality Plans. Clause 4 is related to the maintenance of the Capability Approval. NOTE Quality assessment belongs to the negotiation between customers and manufacturers. The following clauses are intended to be a guide when there is a request for a third-party Capability Approval. However, it may also be used as the basis for second-party or self-certification.

Multicore and symmetrical pair/quad cables for digital communications - Part 5-2: Symmetrical pair/quad cables with transmission characteristics up to 600 MHz - Horizontal floor wiring - Capability approval - Sectional specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

This part of IEC 62255 is applicable to polyolefin insulated symmetrical pair/quad telecommunication cables, filled or unfilled with copper conductor intended for broadband digital communications in the local outdoor network. It provides definitions of characteristics, establishes general requirement for materials and cable construction, and details test methods and procedures. Cables are differentiated by bandwidth. They have a maximum referenced frequency of 30 MHz, 60 MHz and 100 MHz. The local cables covered by this standard are divided into two types based on cable design – filled and unfilled. These cables have typically 6 to 300 pairs. The drop cables covered by this standard are divided into two types based on method of installation – aerial and buried. Drop cables typically have a pair-count of 2 to 6 pairs.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 1: Generic specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

This part of IEC 61156 describes symmetrical pair/quad cables intended primarily for work area cabling as defined in ISO/IEC 11801 and ISO/IEC 24702. NOTE Environmental classifications are presented in ISO/IEC 24702 with three levels of severity in four areas: mechanical, ingress, climatic, and electromagnetic: thus, in tabular form, they are referred to as the “MICE table”. This blank detail specification includes recommended environmental characteristics and severities which are derived from the environmental classifications that are specified for cabling for various environments. The blank detail specification determines the layout and style for detail specifications describing symmetrical pair/quad cables with transmission characteristics up to the maximum frequency of the respective category for digital communications. Detail specifications, based on the blank detail specification, may be prepared by a national organization, a manufacturer or a user.

Multicore and symmetrical pair/quad cables for digital communications - Part 6-1: Symmetrical pair/quad cables with transmission characteristics up to 1000 MHz - Working area wiring - Blank detail specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

The application of this blank detail specification relates to multicore and symmetrical pair(s)/ quad(s) cables for digital communications in work area wiring. This blank detail specification determines the layout and style for detail specifications describing multicore and symmetrical pair(s)/quad(s) cables for digital communication in work area wiring. Detail specifications based on the blank detail specification may be prepared by a national standards organization, a manufacturer or a user.

Multicore and symmetrical pair/quad cables for digital communications - Part 3-1: Work area wiring - Blank detail specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

This blank detail specification determines the layout and style for detail specifications describing Multicore and symmetrical pair/quad aerial drop cables for broadband digital communications. Detail specifications, based on the blank detail specification, may be prepared by a national organization, a manufacturer, or a user.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 4-1: Aerial drop cables - Blank detail specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

This part of IEC 61156 applies to capability approval requirements for cables for various communication systems as well as to analog systems, such as video, that exist or are under development and which may use as many as four pairs simultaneously. Clause 2 and its subclauses refer to the content of the capability manual. Clause 3 and its subclauses refer to the related quality layout. Clause 4 is related to the maintenance of the capability approval. NOTE Quality assessment belongs to the negotiation between customers and manufacturers. The following clauses are intended as a guide when there is a request for a third-party capability approval. However, it may also be used as the basis for second party or self-certification.

Multicore and symmetrical pair/quad cables for digital communications - Part 7-2: Symmetrical pair cables with transmission characteristics up to 1 200 MHz - Capability Approval - Sectional specification for digital and analog communication cables

ICS
33.120.20
CCS
发布
2014-12-25
实施

This sectional specification relates to IEC 61156-1:2002. The cables are specifically intended for work area wiring as defined in ISO/IEC 11801. This specification defines individually screened, common overall core screen and unscreened pairs or quads in cables for work area wiring. These cables are suitable for the various communication systems for which the reference is given in the relevant detail specification. The cables covered by this sectional specification are intended to operate with voltages and currents normally adopted for communication systems. These cables should not be connected to low impedance sources, for example, the public mains electricity supply. The recommended temperature range during installation is 0 o C to +50 o C. The actual temperature range during installation shall be indicated in the relevant detail specification. The normal operating temperature range shall be –40 o C to +60 o C.

Multicore and symmetrical pair/quad cables for digital communications - Part 3: Work area cable - Sectional specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

This part of IEC 61156 applies to Capability Approval requirements for cables intended to construct patch, equipment, and work area cords for digital communications in accordance with generic specification IEC 61156-1-1 and Clause 4 of the sectional specification IEC 61156-6. Clause 2 refers to the content of the Capability Manual. Clause 3 refers to the related quality layout. Clause 4 is related to the maintenance of the Capability Approval. NOTE Quality assessment belongs to the negotiation between customers and manufacturers. The following clauses are intended to be a guide when there is a request for a third-party Capability Approval. However, it may also be used as the basis for second-party or self-certification.

Multicore and symmetrical pair/quad cables for digital communications - Part 6-2: Symmetrical pair/quad cables with transmission characteristics up to 600 MHz - Work area wiring - Capability approval - Sectional specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

IEC 61156-6:2010(E) referes to IEC 61156-1. The cables described herein are intended primarily for work area wiring as defined in ISO/IEC 11801 and ISO/IEC 24702. It covers individually screened, common screened and unscreened pairs or quads. The transmission characteristics and the frequency range of the cables are specified at 20 °C. These cables can be used for various communication channels which use as many as four pairs simultaneously. In this sense, this sectional specification provides the cable characteristics required by system developers to evaluate new systems. It cancels and replaces the second edition published in 2007 and constitutes a technical revision. It includes the following significant technical changes with respect to the previous edition: - new requirements for new cables Cat6A, Cat7A; - revised requirements and tests for the cables. This publication shall be read in conjunction with IEC 61156-1:2009.

Multicore and symmetrical pair/quad cables for digital communications - Part 6: Symmetrical pair/quad cables with transmission characteristics up to 1 000 MHz - Work area wiring - Sectional specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

This part of IEC 61156 is applicable to communication systems such as ISDN, local area networks and data communication systems and specifies the definitions, requirements and test methods of multicore, symmetrical pair and quad cables. This standard is also applicable to cables used for customer premises wiring.

Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification

ICS
33.120.20
CCS
发布
2014-12-25
实施

This sectional specification relates to IEC 61156-1:2002. The cables are specifically intended for horizontal floor wiring as defined in ISO/IEC 11801:1995. This specification defines individually screened or unscreened pair/quad cables, with or without overall common screen for horizontal floor wiring. These cables are suitable for the various communication systems for which the reference is given in the relevant detail specification. The cables covered by this sectional specification are intended to operate with voltages and currents normally adopted for communication systems. These cables should not be connected to low impedance sources, for example, the public mains electricity supply. The normal operating temperature range is –40 °C to +60 °C.

Multicore and symmetrical pair/quad cables for digital communications - Part 2: Symmetrical pair/quad cables with transmission characteristics up to 100 MHz - Horizontal floor wiring - Sectional specification

ICS
33.120.20
CCS
发布
2014-12-25
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号