37.040.99 有关摄影技术的其他标准 标准查询与下载



共找到 154 条与 有关摄影技术的其他标准 相关的标准,共 11

This International Standard specifies the principal physical and chemical requirements for filing enclosures, containers, albums and frames, particularly designed for storing wet or dry processed films, plates and papers. This International Standard covers requirements for paper and board, plastic, metal, adhesives (except spray adhesives), writing, labelling and printing materials. It is applicable to photographs made with hardcopy materials. Included are photographs made with traditional chromogenic (“silver-halide”) and silver dye bleach photographic materials, dye- and pigment-based inkjet, dye diffusion thermal transfer (“dye sublimation”), liquid- and dry-toner electrophotography, and other analogue and digital print processes. This International Standard applies to storage copies and does not include work copies as defined in Annex A. It applies to visual records for extended-term preservation and to visual records for preservation for moderate periods of time. The requirements are limited to the characteristics that may affect the enclosed item chemically or physically when it is stored under recommended conditions. (For methods of proper storage, see ISO 18911[15], ISO 18918[17] and ISO 18920[19]). This International Standard does not apply to the material used as a support for prints or documents. (For permanence requirements for paper for documents, see ISO 9706[12]).

Imaging materials - Processed imaging materials - Albums, framing and storage materials

ICS
37.040.99
CCS
G81
发布
2007-12
实施

Imaging materials-Polyester-base magnetic tape-Storage practices

ICS
37.040.99
CCS
发布
2007-11-30
实施

이 규격은 롤 형태인 폴리에스테르 지지체 자기 테이프의 보관 상태, 보관 시설, 동봉물,

Imaging materials-Polyester-base magnetic tape-Storage practices

ICS
37.040.99
CCS
G81
发布
2007-11-30
实施
2007-11-30

Imaging materials-Polyester-base magnetic tape-Storage practices

ICS
37.040.99
CCS
发布
2007-11-30
实施

Radiological film viewing boxes and viewing conditions - Part 1: Requirements and measures of quality assurance in medical diagnostics

ICS
37.040.99
CCS
C43
发布
2007-10
实施

This part of ISO 12234 specifies a basic removable-memory reference model for digital electronic still-picture cameras. The reference model includes image file formats for storing image data and metadata, filing system requirements for storing and retrieving the image files on the removable memory, and media profiles which are specific to a given storage technology. The reference model allows the image data and metadata to be interchanged among the various components of an electronic imaging system by using the removable storage media.

Electronic still-picture imaging - Removable memory - Part 1: Basic removable-memory model

ICS
37.040.99
CCS
A15
发布
2007-10
实施

ISO 18916:2007 specifies the procedure for the photographic activity and dye coupler reactivity tests. ISO 18916:2007 is applicable to general photographic enclosure materials such as paper, tissue, cardboard, mat board and plastics. It is also applicable to components of photographic enclosure materials such as adhesives, inks, paints, labels, and tape. ISO 18916:2007 evaluates possible chemical interactions between enclosures with processed silver-gelatin, colour (dye-gelatin), inkjet prints made with dye-based and pigment-based inks, thermal dye diffusion transfer (“dye sub”) prints, digitally printed dye-diffusion-transfer prints, liquid- and dry-toner xerographic prints, liquid-toner electrostatic prints, and diazo images after long-term storage. It does not pertain to harmful physical interactions such as blocking (sticking together), dye bleed, adhesive migration, or plasticizer exudation. It does not pertain to important criteria of enclosures such as their inherent chemical stability, physical integrity, and workmanship. Passing the photographic activity test (PAT) does not indicate that a material is archival. This term has no clear definition and is not used in this standard. Photo-safe, storage enclosures and their components are covered in ISO 18902, which includes passing the criteria of the photographic activity test. If a particular brand of commercially made enclosure materials is found to be safe for long-term storage purposes, there is no assurance that subsequent batches will contain the same ingredients of the same purity, chemical inertness, concentrations, or sound and sturdy construction. For this reason, materials are tested annually or upon each formulation or supplier change. For materials which are manufactured in a variety of colours, such as papers and inks, each colour is evaluated and reported separately.

Imaging materials - Processed imaging materials - Photographic activity test for enclosure materials

ICS
37.040.99
CCS
G81
发布
2007-07-31
实施
2007-07-31

This International Standard specifies the procedure for the photographic activity and dye coupler reactivity tests. This International Standard is applicable to general photographic enclosure materials such as paper, tissue, cardboard, mat board and plastics. It is also applicable to components of photographic enclosure materials such as adhesives, inks, paints, labels, and tape. This International Standard evaluates possible chemical interactions between enclosures with processed silver-gelatin, colour (dye-gelatin), inkjet prints made with dye-based and pigment-based inks, thermal dye diffusion transfer (“dye sub”) prints, digitally printed dye-diffusion-transfer prints, liquid- and dry-toner xerographic prints, liquid-toner electrostatic prints, and diazo images after long-term storage. It does not pertain to harmful physical interactions such as blocking (sticking together), dye bleed, adhesive migration, or plasticizer exudation. It does not pertain to important criteria of enclosures such as their inherent chemical stability, physical integrity, and workmanship. Passing the photographic activity test (PAT) does not indicate that a material is archival. This term has no clear definition and is not used in this standard. Photo-safe, storage enclosures and their components are covered in ISO 18902, which includes passing the criteria of the photographic activity test. If a particular brand of commercially made enclosure materials is found to be safe for long-term storage purposes, there is no assurance that subsequent batches will contain the same ingredients of the same purity, chemical inertness, concentrations, or sound and sturdy construction. For this reason, materials are tested annually or upon each formulation or supplier change. For materials which are manufactured in a variety of colours, such as papers and inks, each colour is evaluated and reported separately. For enclosures intended for use with any of the above imaging processes, only the black-and-white PAT described in Clauses 4 to 7 are applicable. The dye coupler reactivity test is optional as the results are valid only for the specific colour print product being investigated. Different colour print products can have different staining sensitivities. For enclosures intended for use with diazo images, only the diazo PAT described in 8.5 is applicable.

Imaging materials - Processed imaging materials - Photographic activity test for enclosure materials

ICS
37.040.99
CCS
G81
发布
2007-06
实施

Radiological film viewing boxes and viewing conditions - Part 3: Radiological film viewing boxes for dentistry

ICS
37.040.99
CCS
C43
发布
2007-05
实施

Electronic still-picture imaging-Removable memory-Part 2:TIFF/EP image data format

ICS
37.040.99
CCS
发布
2006-12-28
实施

이 규격에서는 KS M ISO 12234-1에서 기술한 TIFF/EP 데이터 형식에 관해

Electronic still-picture imaging-Removable memory-Part 2:TIFF/EP image data format

ICS
37.040.99
CCS
A15
发布
2006-12-28
实施
2006-12-28

Electronic still-picture imaging-Removable memory-Part 2:TIFF/EP image data format

ICS
37.040.99
CCS
发布
2006-12-28
实施

This International Standard provides suggested guidelines for four temperature and humidity macroenvironments for archives that contain a variety of recording media, based on the corresponding ISO storage standards for those media. Whenever possible, it is advisable to follow the storage environments in the ISO storage standards. This International Standard does not replace these ISO storage standards. In addition to environment recommendations, those standards also include other vital information pertinent for the long-term keeping of recording materials, such as inspection, housing, and handling guidelines. Although microenvironments within a storage enclosure can be dependent upon the macroenvironment, they are not the focus of this International Standard. The storage of traditional paper collections is not within the scope of this International Standard. However, many archives containing mixed recording media also include such collections. Archivists are encouraged to review the appropriate standards (see References [1] and [2] in the Bibliography) for those materials. Nitrate-base photographic films are also included in this International Standard, since they are often stored together with other materials in spite of the fact that nitrate films represent a fire hazard and they need to be stored in accordance with the National Fire Protection Association standard[3] in the United States, or other applicable national standards. Moreover, fumes from decomposing nitrate film and acetate-base film can have very detrimental effects on other materials stored in the same area.[11] It is necessary to isolate such films in a separate storage area.

Imaging materials - Multiple media archives - Storage environment

ICS
37.040.99
CCS
L81;A14
发布
2006-05-15
实施

Photography-Spatial resolution measurements of electronic scanners for photographic image-Part 1:Scanners for reflective media

ICS
37.040.99
CCS
发布
2005-12-14
实施

이 규격은 연속톤의 네거티브와 리버셜(reversal) 필름용 전자식 스캐너의 공간 해상도

Photography-Electronic scanners for photographic images-Spatial resolution measurement-Part 2:Film scanners

ICS
37.040.99
CCS
N41
发布
2005-12-14
实施
2005-12-14

이 규격은 사진 출력물을 위한 연속톤 전자식 스캐너의 공간 해상도 측정법과 보고 방법에

Photography-Spatial resolution measurements of electronic scanners for photographic image-Part 1:Scanners for reflective media

ICS
37.040.99
CCS
N41
发布
2005-12-14
实施
2005-12-14

Photography-Electronic scanners for photographic images-Spatial resolution measurement-Part 2:Film scanners

ICS
37.040.99
CCS
发布
2005-12-14
实施

이 규격은 전자식 정지 영상 카메라의 노이즈와 신호 레벨, 노이즈와 다이내믹 레인지의 관계

Photography-Electronic still-picture cameras-Noise measurementsNoise measurements

ICS
37.040.99
CCS
C35
发布
2005-12-14
实施
2005-12-14

이 규격은 다양한 장소에서의 실외 기후 시험을 위해 표본을 준비하고 그 결과를 제출하기 위

Imaging materials-Protocols for outdoor weathering experiments

ICS
37.040.99
CCS
G81
发布
2005-05-16
实施
2005-05-16

This International Standard provides specifications for adhesive mounting materials for use in attaching prints including photographic, electrophotographic, electrostatic, thermal transfer, or inkjet prints to mounting boards, album leaves, file cards, and other supports. This International Standard covers both pressure-sensitive and thermally-activated adhesives1). Spray adhesives are specifically excluded from this International Standard.

Imaging materials - Adhesive mounting systems - Specifications

ICS
37.040.99
CCS
G81
发布
2005-03
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号