共找到 902 条与 实验室器皿和有关仪器 相关的标准,共 61 页
لا يوجد
Laboratory glassware -- Bottles -- Part 3: Aspirator bottles
ISO 24450:2005 specifies requirements and dimensions for an internationally acceptable series of conical flasks and of flat-bottom and round-bottom flasks with wide neck for general laboratory purpose. The flasks are provided for direct use in laboratory, fitting together with other equipment for general laboratory purposes, and for further work up to other products. For narrow-necked boiling flasks, ISO 1773 applies. For boiling flasks with conical ground joints, see ISO 4797.
Laboratory glassware -- Wide-necked boiling flasks
The requirements specify material including its hydrolytic resistance and thermal coefficient of expansion. The range of sizes and tolerance and external diameters and well thickness are tabled and described. In a second table the limits on bow for different external diameters are specified.
Laboratory glassware -- Borosilicate glass tubing
The requirements deal with the geometric charateristics to ensure interchangeability. The dimensions of the joint-ground zone and the outer diameter of the tube connected to the joint are given in a table and illustrated in a drawing. In addition the surface finish is specified. A system of gauges (stell balls) for testing the ball cup is tabled. In the annex a method of testing the leakage including the apparatus is described.
Laboratory glassware -- Interchangeable spherical ground joints
Filters are graded according to their pore size index in one of the eight classes specified. This is applicable to laboratory filters made of glass, vitreous silica, ceramics, metals and plastic materials. Annex A specifies a method for determination of pore size index. Annex B and C concern with a procedure for assessing uniformity of filters and for determination of air permeability.
Laboratory sintered (fritted) filters -- Porosity grading, classification and designation
Describes a test method for determining the stresses which may occur after the sealing of two glasses by means of stress birefringence.
Glass-to-glass sealings -- Determination of stresses
Standard Specification for Laboratory Glass Multiple Neck Distilling/Boiling Flasks
Standard Specification for Common Laboratory Glass Funnels
This part of ISO 4802 specifies a) a method for determining the hydrolytic resistance of the interior surfaces of glass containers when subjected to attack by water at 121 °C ± 1 °C for 60 min ± 1 min. The resistance is measured by titration of a known aliquot portion of the extraction solution produced with hydrochloric acid solution, in which case the resistance is inversely proportional to the volume of acid required; b) a classification of glass containers according to the hydrolytic resistance of the interior surfaces determined by the methods specified in this part of ISO 4802.
Glassware - Hydrolytic resistance of the interior surfaces of glass containers - Part 2: Determination by flame spectrometry and classification
This part of ISO 4802 specifies a) a method for determining the hydrolytic resistance of the interior surfaces of glass containers when subjected to attack by water at 121 °C ± 1 °C for 60 min ± 1 min. The resistance is measured by titration of a known aliquot portion of the extraction solution produced with hydrochloric acid solution, in which case the resistance is inversely proportional to the volume of acid required; b) a classification of glass containers according to the hydrolytic resistance of the interior surfaces determined by the methods specified in this part of ISO 4802.
Glassware - Hydrolytic resistance of the interior surfaces of glass containers - Part 1: Determination by titration method and classification
This International Standard specifies requirements and test methods for plain, single-use Petri dishes for microbiological use. This International Standard does not apply to products of similar design which may be used for cell or tissue culture purposes. Neither does it apply to dishes supplied ready loaded with microbiological media.
Plastics laboratory ware - Single-use Petri dishes for microbiological procedures
Plastics laboratory ware. Single-use Petri dishes for microbiological procedures
Laboratory glassware - Three-neck bottles - Woulff bottles
Specifies dimensions, material and constructional and metrological requirements of graduated measuring cylinders of tall form (Type 1a and Type 1b) and of squat form (Type 2). All types are suitable for general laboratory use.
Laboratory glassware - Graduated measuring cylinders
Specifies metrological and constructional requirements for volumetric pipettes with one mark (total delivery) and for volumetric pipettes with two marks, both of which are adequate for general laboratory purposes.
Laboratory glassware - Single-volume pipettes
이 표준은 공업용 약품, 농업용 약품, 의료용 약품, 알코올, 증류수 등의 액체를 담는 용
Acid proof glass bottles
1.1 This European Standard applies to centrifuges aiming at separation of liquidlliquidlsolid/solid or at least two of these substances. It gives requirements to minimise the risks caused by the hazards specified in 1.2. The Standard deals with the significant hazards associated with the operation of centrifuges. 1.2 The Standard gives requirements for minimising the risks caused by the following hazards: -- mechanical hazards common to all types of centrifuges, except those specified in 1.3; -- ergonomical hazards; -- electrical hazards. The standard also covers requirements for noise measurements. 1.3 Types of centrifuges and hazards excluded 1.3.1 Types of centrifuges excluded: -- centrifuges with a kinetic energy of rotation less than 200 Joule; -- centrifuges designated by their manufacturers for domestic use; -- centrifuges designated by their manufacturers as laboratory centrifuges according to EN 61010-2-020, including Amendment 1 ; -- centrifuges designated by their manufacturers for forming, i.e. centrifugal hot metal casting machines. 1.3.2 Hazards excluded: -- thermal hazards; -- hazards specific to processing radioactive products; -- hazards specific to microbiological processing - including viral and parasitic hazards; -- hazards from processing corrosive and/or erosive materials; -- hazards from processes involving flammable or explosive substances; -- hazards caused by leakage of hazardous substances; -- hazards caused by unsuitable hygienic design for applications involving food products; -- other application specific hazards which must be dealt with, either according to application specific standards (e.g. EN 12505 ), or EN 292. 1.4 This standard applies to centrifuges which are manufactured after the date of issue of this standard.
Centrifuges - Common safety requirements (includes Amendment A1:2009); English version of DIN EN 12547:2009-09
Centrifuges - Common safety requirements
Laboratory glassware-Narrow-necked boiling flasks
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved