71.080.15 (Aromatic hydrocarbons) 标准查询与下载



共找到 147 条与 相关的标准,共 10

1.1 This specification covers benzene for use with zeolite based catalysts.1.2 The following applies to all specified limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off "to the nearest unit" in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E 29. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.4 Consult current OSHA regulations, supplier's Material Safety Data Sheets, and local regulations for all materials used in this specification.

Standard Specification for Benzene for use with Zeolite Based Catalysts

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G16
发布
2005
实施

1.1 These test methods cover the sampling and chemical analysis of paste, powder, or liquid detergent alkylbenzene sulfonates.1.2 The procedures for sampling and analysis appear in the following order: SectionsSampling:Powders and Flakes Packed in Cans or Cartons3Powders and Flakes in Bulk4Liquids6Pastes7 Hazards8Preparation of Sample9 Moisture:Distillation Method11-14Karl Fischer Method15-20Total Matter Insoluble in Alcohol21-23Neutral Oil24-27Chlorides Calculated as Sodium Chloride (NaCl)28-31pH321.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazards statement, see Section .

Standard Test Methods for Sampling and Chemical Analysis of Alkylbenzene Sulfonates

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G72
发布
2005
实施

1.1 These test methods cover the sampling and chemical analysis of paste, powder, or liquid detergent alkylbenzene sulfonates. 1.2 The procedures for sampling and analysis appear in the following order:   Sections     Sampling:   8199;Powders and Flakes Packed in Cans or Cartons 3 8199;Powders and Flakes in Bulk 4 8199;Liquids 6 8199;Pastes 7 Hazards 8 Preparation of Sample 9 Moisture:   8199;Distillation Method 11 – 14 8199;Karl Fischer Method 15 – 20 Total Matter Insoluble in Alcohol 21 – 23

Standard Test Methods for Sampling and Chemical Analysis of Alkylbenzene Sulfonates

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
发布
2005
实施

1.1 This specification covers a grade of o-xylene identified as ortho-Xylene 980.1.2 The following applies to all specified limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off to the nearest unit in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E 29.1.3 Consult current OSHA regulations and supplier's Material Safety Data Sheets, and local regulations for all materials used in this specification.

Standard Specification for O-Xylene 980

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G16
发布
2004
实施

This test method is suitable for setting specifications on the materials referenced in 1.2 and for use as an internal quality control tool where isopropylbenzene is produced or is used in a manufacturing process. It may also be used in development or research work involving isopropylbenzene. This test method is useful in determining the purity of isopropylbenzene with normal impurities present. If extremely high boiling or unusual impurities are present in the isopropylbenzene, this test method would not necessarily detect them and the purity calculation would be erroneous. Cumene hydroperoxide, if present, will yield thermal decomposition products, primarily AP and DMPC as stated in 4.1, that will elute in the chromatogram thereby giving incorrect results unless they are excluded as indicated in 4.1. It is also possible to get erroneous results for trace alpha-methylstyrene present in isopropylbenzene if the inlet has become unduly contaminated with non-volatile foreign substances. The nonaromatic hydrocarbons commonly present from the isopropylbenzene manufacturing process, particularly a non-zeolitic one, will interfere with the determination of xylenes (if present).1.1 This test method covers the determination of the purity of isopropylbenzene (cumene) by gas chromatography. Calibration of the gas chromatography system is done by the external standard calibration technique.1.2 This test method has been found applicable to the measurement of impurities such as nonaromatic hydrocarbons, benzene, toluene, ethylbenzene, phenol, cymenes, t-butylbenzene, n-butylbenzene, n-propylbenzene, alpha-methylstyrene, sec-butylbenzene, and diisopropylbenzenes, which are impurities that can be found in isopropylbenzene. The latter impurities can be analyzed over a range of 1 mg/kg to 500 mg/kg by this method (see Table 1). The limit of detection for these impurities is summarized in Table 1 as well.1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E 29.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.

Standard Test Method for Analysis of Isopropylbenzene (Cumene) by Gas Chromatography (External Standard)

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G16
发布
2004
实施

1.1 This test method covers the determination of total chloride (organic and inorganic) in liquid aromatic hydrocarbons and cyclohexane. 1.2 The test method is applicable to samples with chloride concentrations of 1 to 25 mg/kg.1.3 Bromides and iodides, if present, will be calculated as chlorides.1.4 Materials, such as styrene, that are polymerized by sodium biphenyl reagent cannot be analyzed by this test method.1.5 The following applies to all specified limits in this test method: for purposes of determining conformance with this test method, an observed value or a calculated value shall be rounded off "to the nearest unit" in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E 29.1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Section .

Standard Test Method for Trace Chloride in Liquid Aromatic Hydrocarbons

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G16
发布
2004
实施

This test method is suitable for setting specifications, for use as an internal quality control tool, and for use in development or research work on industrial aromatic hydrocarbons and related materials. This test method gives an indication of residual acidity and is a measure of the quality of the finished product. It is an indication of the tendency of the product to corrode equipment.1.1 This test method is intended for the detection of acidity and for the quantitative determination of acidity of benzene, toluene, xylenes, solvent naphthas, and similar industrial aromatic hydrocarbons.1.2 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E 29.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements see Section 8.

Standard Test Method for Acidity of Benzene, Toluene, Xylenes, Solvent Naphthas, and Similar Industrial Aromatic Hydrocarbons

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G16
发布
2004
实施

1.1 This standard is for use in calculating the weight and volume of benzene, toluene, mixed xylenes, styrene, ortho-xylene, meta-xylene, para-xylene, cumene, ethylbenzene, 300 to 350176;F and 350 to 400176;F aromatic hydrocarbons, and cyclohexane. A method is given for calculating the volume at 60176;F from an observed volume at t176;F. Table 1 lists the density in pounds per gallon at 60176;F for high purity chemicals.1.2 Calculated results shall be rounded off in accordance with the rounding-off method of Practice E 29.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Calculation of Volume and Weight of Industrial Aromatic Hydrocarbons and Cyclohexane

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G17
发布
2004
实施

1.1 This standard is for use in calculating the weight and volume of benzene, toluene, mixed xylenes, styrene, ortho-xylene, meta-xylene, para-xylene, cumene, ethylbenzene, 300 to 350176;F and 350 to 400176;F aromatic hydrocarbons, and cyclohexane. A method is given for calculating the volume at 60176;F from an observed volume at t176;F. Table 1 lists the density in pounds per gallon at 60176;F for high purity chemicals.1.2 Calculated results shall be rounded off in accordance with the rounding-off method of Practice E 29.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Calculation of Volume and Weight of Industrial Aromatic Hydrocarbons and Cyclohexane

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G17
发布
2004
实施

This test method is suitable for use in calculating weights and volumes of the products outlined in Section 1. The information presented can be used for determining quantities of the above-stated aromatic hydrocarbons in tanks, shipping containers, etc.1.1 This standard is for use in calculating the weight and volume of benzene, toluene, mixed xylenes, styrene, ortho-xylene, meta-xylene, para-xylene, cumene, ethylbenzene, 300 to 350F and 350 to 400F aromatic hydrocarbons, and cyclohexane. A method is given for calculating the volume at 60F from an observed volume at tF. lists the density in pounds per gallon at 60F for high purity chemicals.1.2 Calculated results shall be rounded off in accordance with the rounding-off method of Practice E 29.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Calculation of Volume and Weight of Industrial Aromatic Hydrocarbons and Cyclohexane

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G17
发布
2004
实施

1.1 This specification covers styrene monomer. 1.2 Consult current OSHA regulations and supplier's Material Safety Data Sheets for all materials used in this specification. 1.3 The following applies to all specified limits in this standard: for purposes of determining conformance with this standard, an observed value or a calculated value shall be rounded off "to the nearest unit" in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.

Standard Specification for Styrene Monomer

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G17
发布
2004
实施

1.1 This specification covers cumene (isopropylbenzene) manufactured using a zeolite catalyst process. 1.2 The following applies to all specified limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off "to the nearest unit" in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E 29.1.3 Consult current OSHA Regulations and Supplier's Material Safety Data Sheets, and local regulations for all materials used in this specification.

Standard Specification for Cumene (Isopropylbenzene) Manufactured Via a Zeolite Process

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G17
发布
2004
实施

1.1 This standard is for use in calculating the weight and volume of benzene, toluene, mixed xylenes, styrene, ortho-xylene, meta-xylene, para-xylene, cumene, ethylbenzene, 148.9 to 176.7176;C and 176.7 to 204.4176;C aromatic hydrocarbons, and cyclohexane. A method is given for calculating the volume at 15176;C from an observed volume at t176;C. Table 1 lists the density in grams per cubic centimetre at 15176;C for high purity chemicals.1.2 Calculated results shall be rounded off in accordance with the rounding-off method of Practice E 29.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Calculation of Volume and Weight of Industrial Aromatic Hydrocarbons and Cyclohexane [Metric]

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G17
发布
2004
实施

1.1 This standard is for use in calculating the weight and volume of benzene, toluene, mixed xylenes, styrene, ortho-xylene, meta-xylene, para-xylene, cumene, ethylbenzene, 148.9 to 176.7176;C and 176.7 to 204.4176;C aromatic hydrocarbons, and cyclohexane. A method is given for calculating the volume at 15176;C from an observed volume at t176;C. Table 1 lists the density in grams per cubic centimetre at 15176;C for high purity chemicals.1.2 Calculated results shall be rounded off in accordance with the rounding-off method of Practice E 29.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Calculation of Volume and Weight of Industrial Aromatic Hydrocarbons and Cyclohexane [Metric]

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G17
发布
2004
实施

1.1 This test method covers the determination of the total nonaromatic hydrocarbons, and trace monocyclic aromatic hydrocarbons in the purity of toluene and mixed xylenes by gas chromatography.1.2 Nonaromatic aliphatic hydrocarbons containing 1 through 10 carbon atoms (methane through decanes) can be detected by this test method at concentrations ranging from 0.001 % to 2.500 weight %.1.2.1 A small amount of benzene in mixed xylenes may not be distinguished from the nonaromatics and the concentrations are determined as a composite.1.3 Monocyclic aromatic hydrocarbon impurities containing 6 through 9 carbon atoms (benzene through C9 aromatics) can be detected by this test method at individual concentrations ranging from 0.001 % to 1.000 weight %.1.4 The following applies to all specified limits in this test method: for purposes of determining conformance with this standard, an observed value or a calculated value shall be rounded off "to the nearest unit" in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E 29.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statement, see Section 9.

Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G17
发布
2004
实施

1.1 This test method covers the determination of the total nonaromatic hydrocarbons, and trace monocyclic aromatic hydrocarbons in the purity of toluene and mixed xylenes by gas chromatography.1.2 Nonaromatic aliphatic hydrocarbons containing 1 through 10 carbon atoms (methane through decanes) can be detected by this test method at concentrations ranging from 0.001 % to 2.500 weight %.1.2.1 A small amount of benzene in mixed xylenes may not be distinguished from the nonaromatics and the concentrations are determined as a composite.1.3 Monocyclic aromatic hydrocarbon impurities containing 6 through 9 carbon atoms (benzene through C9 aromatics) can be detected by this test method at individual concentrations ranging from 0.001 % to 1.000 weight %.1.4 The following applies to all specified limits in this test method: for purposes of determining conformance with this standard, an observed value or a calculated value shall be rounded off "to the nearest unit" in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E 29.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statement, see Section 9.

Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G17
发布
2004
实施

1.1 This test method covers the determination of the total nonaromatic hydrocarbons, and trace monocyclic aromatic hydrocarbons in the purity of toluene and mixed xylenes by gas chromatography.1.2 Nonaromatic aliphatic hydrocarbons containing 1 through 10 carbon atoms (methane through decanes) can be detected by this test method at concentrations ranging from 0.001 % to 2.500 weight %.1.2.1 A small amount of benzene in mixed xylenes may not be distinguished from the nonaromatics and the concentrations are determined as a composite.1.3 Monocyclic aromatic hydrocarbon impurities containing 6 through 9 carbon atoms (benzene through C9 aromatics) can be detected by this test method at individual concentrations ranging from 0.001 % to 1.000 weight %.1.4 The following applies to all specified limits in this test method: for purposes of determining conformance with this standard, an observed value or a calculated value shall be rounded off "to the nearest unit" in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E 29.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statement, see Section 9.

Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G17
发布
2004
实施

1.1 This test method covers the analysis of normally occurring impurities in, and the purity of, o-xylene by gas chromatography. Impurities determined include nonaromatic hydrocarbons, benzene, toluene, p- and m-xylenes, cumene, styrene, and ethylbenzene.1.2 This test method is applicable for impurities at concentrations from 0.001 to 2.000 % and for o-xylene purities of 98 % or higher.1.3 The following applies to all specified limits in this standard: for purposes of determining conformance with this standard, an observed value or a calculated value shall be rounded off "to the nearest unit" in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E 29.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Section 8.

Standard Test Method for Analysis of o-Xylene by Gas Chromatography

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G16
发布
2004
实施

1.1 This specification covers cumene (isopropylbenzene).1.2 The following applies to all specified limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off "to the nearest unit" in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E 29.1.3 Consult current OSHA Regulations and Supplier's Material Safety Data Sheets, and local regulations for all materials used in this specification.

Standard Specification for Cumene (Isopropylbenzene)

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G16
发布
2004
实施

1.1 This specification covers a grade of o-xylene identified as ortho-Xylene 980.1.2 The following applies to all specified limits in this specification: for purposes of determining conformance with this specification, an observed value or a calculated value shall be rounded off to the nearest unit in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E 29.1.3 Consult current OSHA regulations and supplier's Material Safety Data Sheets, and local regulations for all materials used in this specification.

Standard Specification for O-Xylene 980

ICS
71.080.15 (Aromatic hydrocarbons)
CCS
G16
发布
2004
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号