91.040.01 建筑物综合 标准查询与下载



共找到 718 条与 建筑物综合 相关的标准,共 48

本指南共包括9章,主要技术内容是:1.总则;2.术语;3.规划与建筑;4.结构与建筑工业化;5.暖通空调与可再生能源利用;6.给水排水;7.电气与智能化;8.景观设计;9.施工管理与运行。

Technical Guidelines for Green Building Applications

ICS
91.040.01
CCS
E4710
发布
2023-03-21
实施
2023-04-21

Specifications for the maintenance and upkeep of historic buildings

ICS
91.040.01
CCS
P36
发布
2023-03-20
实施
2023-06-20

Technical requirements for government procurement of green buildings and green building materials

ICS
91.040.01
CCS
P33
发布
2023-03-20
实施
2023-03-21

1.1 Purpose—The purpose of this guide2 is to define good commercial practice for conducting a limited survey for readily observable moisture affected materials and conditions conducive to elevated moisture in a commercial building related to commercial real estate transaction or commercial real estate management by conducting: a walk-through survey, document reviews, and interviews as outlined within this guide. This guide is intended to provide a practical means for the limited identification of moisture affected materials and physical deficiencies conducive to elevated moisture caused by water infiltration through the building envelope or substructure or generated within the subject building as a result of processes or mechanical systems, excluding de minimis conditions. This guide is to allow a user to assess general moisture concerns, as well as the potential need for further assessment or other actions that may be appropriate that are beyond the scope of this guide. For purposes of this guide, the initialism “LMA” or “Limited Moisture Assessment” is used interchangeably with this guide’s full title. 1.2 Purpose Limitations—While a LMA may be used to survey for readily identifiable moisture affected materials and physical deficiencies conducive to elevated moisture, the LMA is not designed to serve as comprehensivesurvey for the presence of moisture affected materials and physical deficiencies conducive to elevated moisture in all or most areas in a commercial building. It is not intended to reduce or eliminate the risks that elevated moisture may pose to the subject building or its occupants. 1.3 Considerations Beyond This Scope—The use of this guide is limited to the scope set forth in this section. Section 12 of this guide identifies, for informational purposes, certain physical conditions (not an all-inclusive list) that may exist at a subject property and certain activities or procedures (not an all-inclusive list) that are beyond the scope of this guide but may warrant consideration by users. The need to investigate any such conditions in the provider’s scope of services should be evaluated based upon, among other factors, the nature of the subject property and the reason for conducting the LMA. The scope of such further investigation or testing services should be agreed upon between the user and the provider as additional services, which are beyond the scope of this guide, prior to initiation of the LMA process. The responsibility to initiate work beyond the scope of this guide lies with the user. 1.3.1 Sampling for suspect fungi and other forms of biological growth is a non-scope consideration under this guide. 1.3.2 Sampling or otherwise measuring for moisture is a non-scope consideration under this guide. 1.4 Organization of the Guide—This guide has 13 sections and two appendices. Section 1 defines the Scope. Section 2 is Referenced Documents. Section 3 is Terminology. Section 4 defines the Significance and Use of this guide. Section 5 describes User Responsibilities. Sections 6 through 11 provide guidelines for the main body of the report, including the scope of the walk-through survey and preparation of the report. Section 12 identifies Out of Scope Considerations. Section 13 lists keywords for Internet reference. Appendix X1 provides the user with a suggested Interview Checklist, and Appendix X2 provides the user with a suggested Field Checklist. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. 1 This guide is under the jurisdiction of ASTM Committee E50 on Environmental Assessment, Risk Management and Corrective Action and is the direct responsibility of Subcommittee E50.02 on Real Estate Assessment and Management. Current edition approved March 15, 2023. Published April 2023. Originally approved in 2015. Last previous edition approved in 2015 as E3026–15. DOI: 10.1520/E3026–23E01 2 Whenever terms defined in Section 3 are used in this guide, they are in italics. Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. 1 2. Referenced Documents

Standard Guide for Readily Observable Moisture Affected Materials and Conditions Conducive to Elevated Moisture in Commercial Buildings: Limited Moisture Assessment Process

ICS
91.040.01
CCS
发布
2023-03-15
实施

Standard Guide for Readily Observable Moisture Affected Materials and Conditions Conducive to Elevated Moisture in Commercial Buildings: Visual Moisture Assessment Process

ICS
91.040.01
CCS
发布
2023-03-15
实施

BS ISO 22185-2. Diagnosing moisture damage in buildings and implementing countermeasures - Part 2. Condition assessment

ICS
91.040.01
CCS
发布
2023-03-10
实施
2023-03-10

  Scope is not provided for this standard

Standard Guide for Water Stewardship in the Design, Construction, and Operation of Buildings

ICS
91.040.01
CCS
发布
2023-02-28
实施

BS ISO 11855-6 AMD 1. Building environment design. Design, dimensioning, installation and control of embedded radiant heating and cooling systems - Part 6. Control

ICS
91.040.01
CCS
发布
2023-02-28
实施
2023-02-28

This document provides a basic step-by-step approach for achieving non-residential (net) zero-energy buildings (ZEBs). It also describes the basic concept of ZEBs and the items for consideration in this approach. The following are within the scope of this document: —    application to non-residential buildings; —    annual energy consumption of a ZEB (this includes the operating consumption of the building and excludes the energy consumed by the manufacturing of materials and equipment, and the energy consumed during construction); —    renewable energy supply (this can be on-site or off-site, depending on the policy and conditions of the country in which the supply is installed); —    application to any climate zone. The following are out of the scope of this document: —    recommendations or suggestions for the adoption of any specific technologies and/or equipment and materials that are expected to be continuously innovated (however it does stipulate the technologies for selection); —    specific methods or calculation formulae; —    commissioning methods.

Methodology for achieving non-residential zero-energy buildings (ZEBs)

ICS
91.040.01
CCS
发布
2023-02-28
实施

This document provides the principles and requirements to enable environmental and technical data provided in EPDs for construction products and services, construction elements and integrated technical systems to be used in BIM to assist in the assessment of the environmental performance of a construction works over its life cycle. This document gives requirements on structuring EPD information using a data template according to ISO 23386 and ISO 23387, to make EPD data machine-interpretable and to enable their integration into information-driven design, construction, use and end-of-life stages. This document is applicable to structuring generic LCA data for use within a BIM environment, as these data are required in the absence of suitable EPD data to enable assessment of the environmental performance at the construction works level. The assessment of environmental performance at the construction works level is not covered by this document.

Sustainability in buildings and civil engineering works — Data templates for the use of environmental product declarations (EPDs) for construction products in building information modelling (BIM)

ICS
91.040.01
CCS
发布
2023-02-28
实施

本文件规定了施工图信息模型智能化审查的总体要求、审查程序、审查范围及审查结果,通过资料性附录形式记录了建设工程BIM施工图审查系统的审查内容。

Specifications for intelligent review of construction drawing information model for construction engineering

ICS
91.040.01
CCS
P30
发布
2023-02-15
实施
2023-02-18

本文件规定了满足计算机智能化审查的施工图信息模型设计及交付要求,明确了施工图信息模型智能化审查所必备的建模标准及属性信息。

Specifications for the delivery of construction drawing information model design for architectural engineering

ICS
91.040.01
CCS
P30
发布
2023-02-15
实施
2023-02-18

本文件规定了竣工信息模型交付物要求、交付流程及交付标准。

Specifications for delivery of construction project completion information model

ICS
91.040.01
CCS
P30
发布
2023-02-15
实施
2023-02-18

BS EN ISO 11855-4 AMD 1. Building environment design. Embedded radiant heating and cooling systems - Part 4. Dimensioning and calculation of the dynamic heating and cooling capacity of Thermo Active Building Systems (TABS)

ICS
91.040.01
CCS
发布
2023-01-24
实施
2023-01-24

BS EN ISO 11855-2 AMD 1. Building environment design. Embedded radiant heating and cooling systems - Part 2. Determination of the design heating and cooling capacity

ICS
91.040.01
CCS
发布
2023-01-24
实施
2023-01-24

BS EN ISO 11855-5 AMD1. Building environment design. Embedded radiant heating and cooling systems - Part 5. Installation

ICS
91.040.01
CCS
发布
2023-01-24
实施
2023-01-24

BS EN ISO 11855-3 AMD1. Building environment design. Embedded radiant heating and cooling systems - Part 3. Design and dimensioning

ICS
91.040.01
CCS
发布
2023-01-20
实施
2023-01-20

1、建立医院智慧病房数字化应用现状评估和持续改进体系,评估医院开展智慧病房应用标准水平。 2、明确不同级别医院的智慧病房数字化应用应当实现的功能,为智慧病房建设提供指南,指导医院科学、合理、有序地开发、应用智慧病房各类信息系统。 3、引导医院沿着功能实用、信息共享、数字治理的方向,通过建设、完善医院智慧病房数字化系统,使之成为改善病房业务、智慧设备、安全管理及新技术应用的全生命期管理的有效工具。 4、为医院智慧病房设计实现对象的数字一体化、数字信息化,为后续业务场景、设备管理、后勤运维应用创建数字化系统可识别实体,形成智慧病房应用准确映射的数字化资产。

Digital Application Standard of Hospital Smart Ward

ICS
91.040.01
CCS
Q841
发布
2023-01-04
实施
2023-01-04

1.1 This guide provides a compendium of information and a menu of options for assessment of fungal growth in buildings, but does not recommend a specific course of action. Due to the wide variety of fungal problems affecting buildings and their occupants, and the wide variety of buildings, it is not possible to describe a set of uniform steps that will always be performed during an assessment (that is, a standard practice); therefore the user of this guide must decide which steps are appropriate for a given situation or building. 1.2 This guide is specific to fungal growth, which is only one potential problem in a building environment. It may be part of, but is not intended to take the place of, a comprehensive indoor air quality investigation. 1.3 This guide describes minimum steps and procedures for collecting background information on a building in question, procedures for evaluating the potential for moisture infiltration or collection, procedures for inspection for suspect fungal growth, and procedures beyond the scope of a basic survey that may be useful for specific problems. 1.4 Assessments for fungal growth may be useful wherever fungal growth is suspected, excess moisture has been present or when there are concerns regarding potential fungal growth. 1.5 Periodic fungal assessment in buildings may be a component of preventative maintenance programs. 1.6 This guide is applicable to buildings including residential (for example, single or multi-family), institutional (for example, schools, hospitals), government, public assembly, commercial (for example, office, retail), and industrial facilities. 1.7 Recommendations for developing a sampling strategy or methods for the collection and analysis of fungal samples are beyond the scope of this guide. For recommendations for developing a sampling strategy, see Ref (1)2 , Chapter 10. 1.8 Recommendations for remediation of fungal growth are beyond the scope of this guide. 1.9 This guide is not intended to supersede any government regulations governing the assessment of fungal growth in buildings. 1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Guide for Assessment Of Fungal Growth in Buildings

ICS
91.040.01
CCS
发布
2023-01-01
实施

Green Building Design Standards

ICS
91.040.01
CCS
P33
发布
2022-12-29
实施
2023-07-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号