91.060.50 门窗 标准查询与下载



共找到 1672 条与 门窗 相关的标准,共 112

Standard Practice for Determining the Effects of Temperature Cycling on Fenestration Products

ICS
91.060.50
CCS
发布
2023-07-01
实施

适用于新建、改建、扩建的民用建筑及家装用建筑门窗。一般工业建筑也可适用。

KJ cassette installation water-stop framed system doors and windows

ICS
91.060.50
CCS
E501
发布
2023-06-30
实施
2023-07-03

本文件规定了木塑复合免漆门(以下简称“木塑门”)的术语和定义、基本要求、技术要求、试验方法、检验规则、标志、包装、运输和贮存及质量承诺等。 本文件适用于以PVC膜和木塑板为面材,铝蜂窝、纸蜂窝、空心刨花板等为芯材,单板层积材或木材集成材为框架材料制作的复合免漆门。不适用于防火、防盗、户外等场合。

Paint-free wood plastic composite door

ICS
91.060.50
CCS
C203
发布
2023-06-30
实施
2023-07-30

1.1 This test method sets forth the requirements and testing procedures to test forced-entry-resistant building components, construction components, and specialty security equipment. This test method is intended primarily for manufacturers to test and rate their windows, doors, modular panels, glazings, and similar products to ensure that all manufactured products meet the necessary requirements for forced-entry protection after sustaining an active shooter assault. 1.2 This test method is currently designed to simulate an active shooter weakening the system with repetitive shots followed by mechanically driven impact to simulate forced entry. 1.3 This test method is not to be used for ballistic resistant glazing rating. Test projectiles are permitted to perforate the entire specimen. The test projectile firings are intended to simulate actions taken by an assailant to aid in the ability to gain entry to a facility. 1.4 This is a laboratory test to be performed on full systems and therefore not applicable for field testing. 1.5 All tests are executed on the exterior surface of the fenestration. 1.6 Systems are required to be tested as complete units in a test frame or fielded conditions. Mulled systems must be tested in the mulled condition. Test results only apply to the component or system as tested. Once a system is tested and deemed to satisfy the requirements of this test method, no design change can be made without a retest except those that qualify under Annex A1 Substitution Criteria. 1.7 Components (such as glazing, door leaves, etc.) may be tested in accordance with Appendix X1, receiving a capability statement for the component, but not a system rating per this standard. 1.8 Window and door systems shall be rated to at least a minimum level of Test Methods F476, F588, or F842, or combinations thereof, as appropriate prior to commencing this test evaluation. This test does not dual certify to the above mentioned standards. 1.9 The values stated in this standard are SI units with the exception of the nominal descriptors for tools. 1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Forced-Entry-Resistance of Fenestration Systems After Simulated Active Shooter Attack

ICS
91.060.50
CCS
发布
2023-06-15
实施

本文件规定了无轨自动门的规格和标记、材料与配件、基本规定、要求、试验方法、检验规则、标志、包装、运输和贮存。

Trackless automatic door

ICS
91.060.50
CCS
C331
发布
2023-05-18
实施
2023-05-30

1   Scope This document specifies the test method to determine the air permeability of completely assembled windows and pedestrian door sets of any material, when exposed to positive or negative test pressures . This test method is designed to take account of conditions in use, when the window or door set is installed in accordance with the manufacturer’s specification and the requirements of relevant International Standards and codes of practice. This document does not apply to joints between the window or door frame and the building construction.

Windows and doors. Air permeability. Test method

ICS
91.060.50
CCS
发布
2023-04-30
实施
2023-04-30

1.1 This practice covers the installation of fenestration products in new and existing construction. For the purpose of this practice, fenestration products shall be limited to windows, sliding patio-type doors, swinging patio type doors, and skylights, as used primarily in residential and light commercial buildings. 1.2 This practice assumes that the installer possesses basic woodworking skills and an understanding of wall and roof construction, sheet metal work, and joint sealant practices. 1.3 This practice attempts to instruct and familiarize the installer with the concepts of both Barrier Systems and 1 This practice is under the jurisdiction of ASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.51 on Performance of Windows, Doors, Skylights and Curtain Walls. Current edition approved April 15, 2023. Published May 2023. Originally approved in 2001. Last previous edition approved in 2019 as E2112 – 19c. DOI: 10.1520/E2112-23. *A Summary of Changes section appears at the end of this standard Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. 1 Membrane/Drainage Systems, in order to ensure the continuity of the building envelope. This practice attempts to educate the installer, builder, architect, and other users in the identification and understanding of the water shedding system of the building envelope. 1.4 This practice covers the installation process from preinstallation procedures through post-installation procedures, for single units or factory-mulled multiple units in a single opening. It does not cover the fabrication or assembly of multiple units, whether such fabrication takes place in a factory or at the intended installation site. The installer should check with the manufacturer of factory-assembled units for instructions for anchoring. When using field-mulled units, follow manufacturer’s recommendations and make certain that they meet applicable codes. This practice does not cover the selection of appropriate fenestration products for a given application, nor the selection of other products or systems for use in the installation. 1.5 This practice provides minimum requirements that will help to accomplish the installation of fenestration products in an effective manner. Actual conditions in buildings vary greatly and, in some cases, substantial additional precautions may be required. In the event that the manufacturer’s installation instructions provided with the product conflict with requirements of this practice, the manufacturer’s instructions shall prevail. This practice is not intended to limit or exclude other new procedures that may refine or further improve the effectiveness of fenestration installation. 1.5.1 This practice is intended to be used for background information in order to develop training manuals and training programs. Further, this practice attempts to consolidate and unify the various steps of construction, tying together the various trades involved with the continuity between fenestration products and the building envelope. 1.6 The text of this practice references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this practice. 1.7 This standard has not been created to address all issues related to every possible installation situation one might experience in the field. Furthermore, this practice does not purport to provide fail-safe installation methods, assurance or protection against installation deficiencies, or a standard by which architects can specify or ensure delivered performance. NOTE 1—There are no ISO standards covering the primary subject matter of this practice. 1.8 Design Professional—This practice is not intended to limit the role and authority of a registered design professional to select a method of installation or to change, modify, or develop other methods of installation to meet the specific requirements of a building project for a particular location. A design professional retains the authority to prepare construction documents indicating window/door/skylight installations integrated with the water-resistive barrier (WRB). 1.9 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.10 This practice does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and to determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 5, Related Procedures. Where a lead hazard is known or suspected, refer to ASTM Standards on Lead Hazards Associated with Buildings and to applicable state and federal regulations. Where an asbestos hazard is known or suspected, refer to the ASTM Manual on Asbestos Control, and to applicable state and federal regulations. 1.11 Table of Contents: Section Scope 1 Table of Contents 1.11 Referenced Documents 2 Terminology 3 Definitions 3.1 Description of Terms Specific to this Standard 3.2 Abbreviations 3.3 Significance and Use 4 Related Issues and Procedures 5 Continuity with the Weather Barrier Systems 5.1 Joints and Anchorages 5.2 Moisture Entrapment 5.3 Water-Resistive Barrier 5.4 Weatherability 5.5 Construction Sequence 5.6 Construction Damage 5.7 Inspection 5.8 Rough Opening 5.9 Rough Opening Size 5.9.1 Insulating or Filling the Rough Opening Gap 5.9.2 Materials Protection 5.10 Cleaning and Maintenance 5.11 Dissimilar Materials 5.12 Flashing Requirements 5.13 Fastening Systems/Anchorage 5.14 Shimming 5.15 Pan Flashing Systems and Subsills for Weatherability 5.16 Pre-Installation Procedures 5.17 Sealants—Selection and Use 5.18 Window Cleaner Anchors and Related Safety Hardware 5.19 Continuity Between the Fenestration Products and Other Components of the Building Envelope 6 Water Shedding Strategies of Wall and Roof Systems 7 Concept of Surface Barrier Systems and Membrane/Drainage Systems 7.1 Surface Barrier Systems 7.1.1 Membrane/Drainage Systems 7.1.2 Identification of Systems 7.2 Installation Methods For Windows 8 Windows in Walls Utilizing a Membrane/Drainage System 8.1 Windows with Perimeter Mounting Flanges (Nail Fins) in Drainage Type Wall Construction 8.1.1 Flange Types 8.1.1.1 Selection of Installation Method 8.1.1.2 Method A 8.1.1.3.1 Method B 8.1.1.3.2 Method A1 8.1.1.3.3 Method B1 8.1.1.3.4 Non-Finned Windows in Membrane/Drainage Type Walls 8.1.2 Windows in Walls Utilizing a Barrier Wall System (Sealant Method) 8.2 E2112 − 23 2 Windows in Walls Utilizing an Exterior Barrier System (EIFS or Direct Applied) 8.3 Alternative Approved Installation Methods for the Installation of Windows 8.4 Extreme Wind/Water Conditions 8.4.1 Membrane Drainage Wood Frame Construction 8.4.1.1 Masonry Construction with Surface Barrier Stucco Facade 8.4.1.2 Special Considerations 8.5 Aluminum Framed Windows 8.5.1 Vinyl Framed Windows 8.5.2 Replacement Window Installation 8.6 Partial Window Replacement for Existing Integral Flange Windows 8.6.1 Partial Replacement of Mill Shop Wood Windows 8.6.2 “Mill Shop” Wood Windows (Vertical or Horizontal Sliding) 8.6.2.1 Complete Window Replacement 8.6.3 Destructive Window Replacement (Fin Type) 8.6.3.1 Non-Destructive Window Replacement (Non-Fin Type) 8.6.3.2 Installation Methods for Doors 9 Doors in Walls Utilizing a Membrane/Drainage System 9.1 Doors with Perimeter Mounting Flanges (Nailing Fins) in Drainage Type Wall Construction 9.1.1 Flange Types 9.1.1.1 Selection of Installation Method 9.1.1.2 Method A 9.1.1.4.1 Method B 9.1.1.4.2 Method A1 9.1.1.4.3 Method B1 9.1.1.4.4 Hinged Swing (Non-finned) Doors in Membrane/ Drainage Type Walls 9.1.2 Installation Methods for Skylights 10 Product Types 10.1 Flashing Procedures 10.2 Aluminum/Copper Sheet Flashing 10.3 Aluminum/Copper Step Flashing (Fabricated or Engineered) 10.4 Membrane Flashing 10.5 Post-Installation Procedures 11 Keywords 12 Air Barrier Foam Sealant Used in the Rough Opening Gap Annex A1 Emergency Escape and Rescue Requirements Annex A2 Minimum Height Requirements for Interior Height of Pan Flashing Annex A3 Sealants Annex A4 Window/Door Flashing Types Appendix X1 Cautions for Installation Appendix X2 Other Referenced Installation Guides Appendix X3 Alternate Installation Methods Appendix X4 Air Leakage Sealing of Interior Perimeter Rough Opening (Air & Water Seal) Appendix X5 1.12 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Installation of Exterior Windows, Doors and Skylights

ICS
91.060.50
CCS
发布
2023-04-15
实施

本标准规定了平移开门机的术语定义、产品参数、技术要求、试验方法、检验规则、标志、包装、运输及贮存。 本标准适用于平移开门机的生产和检验。

Sliding door opener

ICS
91.060.50
CCS
C213
发布
2023-03-31
实施
2023-04-03

1   Scope This document specifies the method to be used to determine the damage caused by striking with a soft and heavy body, the face of a closed-door leaf fixed in its own door frame as part of a door set. This document applies to all doors. The method can also be used with respect to a door leaf submitted for a test in a frame, which the manufacturer considers appropriate to and typical for the intended utilization.

Windows and doors. Determination of the resistance to soft and heavy body impact for doors

ICS
91.060.50
CCS
发布
2023-03-31
实施
2023-03-31

1   Scope This document specifies test method to determine the resistance to wind load of completely assembled windows and pedestrian door sets of any materials when exposed to positive or negative test pressures . This test method is designed to take account of conditions in use, when the window or door set is installed in accordance with the manufacture's specification and the requirements of relevant International Standards and codes of practice. This document does not apply to joints between the window or door frame and the building construction. This document is not intended to evaluate strength of the glass.

Windows and doors. Resistance to wind load. Test method

ICS
91.060.50
CCS
发布
2023-03-31
实施
2023-03-31

This document specifies the test method to determine the air permeability of completely assembled windows and pedestrian door sets of any material, when exposed to positive or negative test pressures. This test method is designed to take account of conditions in use, when the window or door set is installed in accordance with the manufacturer’s specification and the requirements of relevant International Standards and codes of practice. This document does not apply to joints between the window or door frame and the building construction.

Windows and doors — Air permeability — Test method

ICS
91.060.50
CCS
发布
2023-03-24
实施
2023-03

This document specifies test method to determine the resistance to wind load of completely assembled windows and pedestrian door sets of any materials when exposed to positive or negative test pressures. This test method is designed to take account of conditions in use, when the window or door set is installed in accordance with the manufacture's specification and the requirements of relevant International Standards and codes of practice. This document does not apply to joints between the window or door frame and the building construction. This document is not intended to evaluate strength of the glass.

Windows and doors — Resistance to wind load — Test method

ICS
91.060.50
CCS
发布
2023-03-10
实施
2023-03

1   Scope This document specifies the method to be used to determine the permanent deformation caused when a vertical load is applied to an open door leaf fixed in its own door frame as part of a door set. This document applies to all vertically hinged or pivoted doors. The method can also be used with respect to a door leaf submitted for test in a frame, which the manufacturer considers appropriate to and typical for the intended utilization.

Hinged or pivoted doors. Determination of the resistance to vertical load

ICS
91.060.50
CCS
发布
2023-02-28
实施
2023-02-28

  Scope is not provided for this standard

Standard Practice for Determining Steady State Thermal Transmittance of Fenestration Systems

ICS
91.060.50
CCS
发布
2023-02-28
实施

Technical requirements for aluminum alloy integrated doors and windows

ICS
91.060.50
CCS
P32
发布
2023-02-17
实施
2023-03-17

This document specifies the method to be used to determine the permanent deformation caused when a vertical load is applied to an open door leaf fixed in its own door frame as part of a door set. This document applies to all vertically hinged or pivoted doors. The method can also be used with respect to a door leaf submitted for test in a frame, which the manufacturer considers appropriate to and typical for the intended utilization.

Hinged or pivoted doors — Determination of the resistance to vertical load

ICS
91.060.50
CCS
发布
2023-02-08
实施
2023-02

This document specifies the method to be used to determine the damage caused by striking with a soft and heavy body, the face of a closed-door leaf fixed in its own door frame as part of a door set. This document applies to all doors. The method can also be used with respect to a door leaf submitted for a test in a frame, which the manufacturer considers appropriate to and typical for the intended utilization.

Windows and doors — Determination of the resistance to soft and heavy body impact for doors

ICS
91.060.50
CCS
发布
2023-02-06
实施
2023-02

1.1 This practice establishes requirements for testing and rating acoustical performance of window, door, skylight, and glazed wall systems, regardless of their method or materials of manufacture. 1.1.1 Operating force, latching force, and air leakage are integral elements of the acoustical performance of window, door, skylight, and glazed wall systems. This practice requires (when applicable) the concurrent testing of operating force, latching force, and air leakage, in addition to the sound transmission loss test. 1.2 This practice establishes the test methodology, specimen criteria, and classification rating system for purposes of determining the acoustical performance levels of window, door, skylight, and glazed wall systems only, and not through openings between such assemblies and adjacent construction. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Determining the Acoustical Performance of Windows, Doors, Skylight, and Glazed Wall Systems

ICS
91.060.50
CCS
发布
2023-02-01
实施

1.1 This test method covers the determination of the resistance of exterior windows, skylights, and doors to water penetration when water is applied to the outdoor face and exposed edges simultaneously with a rapid pulsed air pressure at the outdoor face higher than the pressure at the indoor face. 1.2 This test method is applicable to windows, skylights, or doors alone. Those interested in testing curtain walls to rapid pulsed air pressure differences should use AAMA 501.1-94. 1.3 This test method addresses water penetration through a manufactured assembly. Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass. This test method does not address these issues. 1.4 The proper use of this test method requires a knowledge of the principles of pressure measurement. 1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Water Penetration of Exterior Windows, Skylights, and Doors by Rapid Pulsed Air Pressure Difference

ICS
91.060.50
CCS
发布
2023-02-01
实施

1.1 This test method covers the determination of the resistance of installed exterior windows, curtain walls, skylights, and doors to water penetration when water is applied to the outdoor face and exposed edges simultaneously with a static air pressure at the outdoor face higher than the pressure at the indoor face. 1.2 This test method is applicable to any curtain-wall area or to windows, skylights, or doors alone. It is intended primarily for determining the resistance to water penetration through such assemblies for compliance with specified performance criteria, but it may also be used to determine the resistance to penetration through the joints between the assemblies and the adjacent construction. Other procedures may be appropriate to identify sources of leakage. 1.3 This test method addresses water penetration through a manufactured assembly. Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass. This test method does not address these issues. 1.4 The proper use of this test method requires a knowledge of the principles of pressure measurement. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 7.1. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference

ICS
91.060.50
CCS
发布
2023-02-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号